Influence of preparation design on fit and ceramic thickness of CEREC 3 partial ceramic crowns after cementation

被引:38
作者
Kim, Jae-Hoon [1 ,2 ]
Cho, Byeong-Hoon [1 ,2 ]
Lee, Jin-Hee [1 ,2 ]
Kwon, Soo-Jung [1 ,2 ]
Yi, Young-Ah [3 ]
Shin, Yooseok [4 ,5 ]
Roh, Byoung-Duck [4 ,5 ]
Seo, Deog-Gyu [1 ,2 ]
机构
[1] Seoul Natl Univ, Dept Conservat Dent, Sch Dent, Seoul 110749, South Korea
[2] Seoul Natl Univ, Dent Res Inst, Sch Dent, Seoul 110749, South Korea
[3] Inje Univ, Seoul Paik Hosp, Dept Dent, Seoul, South Korea
[4] Yonsei Univ, Microscpoe Ctr, Dept Conservat Dent, Coll Dent, Seoul 120749, South Korea
[5] Yonsei Univ, Oral Sci Res Ctr, Coll Dent, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
CAD/CAM; internal gap; luting space; marginal gap; micro CT; FIXED PARTIAL DENTURES; IN-VITRO; INTERNAL FIT; LUTING MATERIAL; MARGINAL ACCURACY; CAD/CAM INLAYS; FILM THICKNESS; ADAPTATION; COMPOSITE; SYSTEMS;
D O I
10.3109/00016357.2014.956145
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. This study investigated the influence of preparation design on the marginal and internal gap and ceramic thickness of partial ceramic crowns (PCCs) fabricated with the CEREC 3 system. Materials and methods. Sixteen extracted human mandibular molars were prepared according to two different preparation designs (n = 8): a retentive preparation design with traditional cusp capping (Group I) and a non-retentive preparation design with horizontal reduction of cusps (Group II). PCCs were fabricated from IPS Empress CAD with the CEREC 3 system. The parameters for luting space and minimum occlusal ceramic thickness were set to 30 mm and 1.5 mm, respectively. The fabricated PCCs were cemented to their corresponding teeth with self-adhesive resin cement and were then scanned by micro-computed tomography. The marginal and internal gaps were measured at pre-determined measuring points in five bucco-lingual and three mesio-distal cross-sectional images. The ceramic thicknesses of the PCCs were measured at the measuring points for cusp capping areas. Results. Group II (167.4 +/- 76.4 mu m) had a smaller overall mean gap, which included the marginal and internal gap measurements, than that of Group I (184.8 +/- 89.0 mu m). The internal gaps were larger than the marginal gaps, regardless of preparation design. Group I presented a thinner ceramic thickness in the cusp capping areas than the minimum occlusal ceramic thickness parameter of 1.5 mm. Conclusion. Preparation design had an influence on fit, particularly the internal gap of the PCCs. Ceramic thickness could be thinner than the minimum ceramic thickness parameter.
引用
收藏
页码:107 / 113
页数:7
相关论文
共 43 条
[1]   Resin elasticity and the strengthening of all-ceramic restorations [J].
Addison, O. ;
Marquis, P. M. ;
Fleming, G. J. P. .
JOURNAL OF DENTAL RESEARCH, 2007, 86 (06) :519-523
[2]  
Akbar Jaber Hussain, 2006, J Prosthodont, V15, P155, DOI 10.1111/j.1532-849X.2006.00095.x
[3]   Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth [J].
Beschnidt, SM ;
Strub, JR .
JOURNAL OF ORAL REHABILITATION, 1999, 26 (07) :582-593
[4]   Digital dentistry: an overview of recent developments for CAD/CAM generated restorations [J].
Beuer, F. ;
Schweiger, J. ;
Edelhoff, D. .
BRITISH DENTAL JOURNAL, 2008, 204 (09) :505-511
[5]   Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations [J].
Bindl, A ;
Mörmann, WH .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (06) :441-447
[6]   Clinical and SEM evaluation of all-ceramic chair-side CAD/CAM-generated partial crowns [J].
Bindl, A ;
Mörmann, WH .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2003, 111 (02) :163-169
[7]   Adaptation of all-ceramic fixed partial dentures [J].
Borba, Marcia ;
Cesar, Paulo F. ;
Griggs, Jason A. ;
Della Bona, Alvaro .
DENTAL MATERIALS, 2011, 27 (11) :1119-1126
[8]   Effect of die spacer thickness on shear bond strength of porcelain laminate veneers [J].
Cho, SH ;
Chang, WG ;
Lim, BS ;
Lee, YK .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (03) :201-208
[9]   Clinical performance of chairside CAD/CAM restorations [J].
Fasbinder, Dennis J. .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2006, 137 :22S-31S
[10]   Partial ceramic crowns:: Influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro [J].
Federlin, M. ;
Krifka, S. ;
Herpich, M. ;
Hiller, K-A ;
Schmalz, G. .
OPERATIVE DENTISTRY, 2007, 32 (03) :251-260