Characterization of Scintillation Pulses in Time Determination in TOF-PET

被引:4
|
作者
Guo, Ning [1 ]
Xie, Qingguo [1 ]
Zhu, Jun [1 ]
机构
[1] Wuhan Natl Lab Optoelect, Wuhan, Hubei, Peoples R China
来源
2009 16TH IEEE-NPSS REAL TIME CONFERENCE | 2009年
关键词
Positron Emission Tomography; Pulse characterization; Time determination; TOF;
D O I
10.1109/RTC.2009.5321980
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Scintillation Pulses generated from positron emission tomography (PET) detectors contain the information of annihilation events including timing and energy. Conventionally, the peak of the pulse is used to pick the time information. How ever, little investigation has been reported about the beginning of a pulse which may keep the essential time information. The first optical photon of a scintillation pulse usually submerges in the noise and hard to detect. By characterizing the pulses. we set up a model composed of the leading edge, decay and noise to pick the first photon. The investigation of pulse model may provide in efficient way to improve the timing resolution for time-of-flight (TOF) PET The initial model of scintillation pulse is obtained by averaging an amount of pulses. It gives a rough expression of pulse shape and shows an interesting detail of leading edge which is not a complete straight line but with curves in both ends. To validate the previous scintillation pulse model. we set up the optical transport simulation on Geant4 Application for Tomography Emission (GATE) which could complete the process from the interaction of gamma photon and scintillator to the optical transportation in crystal until being defected by PMT modules. From the simulation, we obtain a pulse library of optical photon pulses. Meanwhile. we get the mean pulse by averaging and the coincidence timing resolution of 58.3 ps FWHM which is determined by the first optical photon. In the further experiments, special detectors are introduced to ensure accordant scintillation Pulses which deposit whole energy (511keV) by photoemission. By averaging the uniformed pulse library. it will show an accurate mean-pulse and noise model. Based on this model. we will optimize the characterization for scintillation pulses and apply it to the time determination by leading edge fitting which is efficient in digital pulse processing for TOF PET.
引用
收藏
页码:304 / 307
页数:4
相关论文
共 50 条
  • [1] Improving TOF-PET by Studying Scintillation Photon Propagation and the Cherenkov Effect
    Brunner, S. E.
    Gruber, L.
    Marton, J.
    Suzuki, K.
    Beyer, T.
    Hirtl, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S132 - S132
  • [2] Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT
    Queiroz, Marcelo A.
    Delso, Gaspar
    Wollenweber, Scott
    Deller, Timothy
    Zeimpekis, Konstantinos
    Huellner, Martin
    Barbosa, Felipe de Galiza
    von Schulthess, Gustav
    Veit-Haibach, Patrick
    PLOS ONE, 2015, 10 (07):
  • [3] Data driven time alignment for TOF-PET
    Rezaei, Ahmadreza
    Schramm, Georg
    Van Laere, Koenraad
    Nuyts, Johan
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [4] TlCl:Be,I: A High Sensitivity Scintillation and Cherenkov Radiator for TOF-PET
    Kratochwil, Nicolaus
    Kaneshige, Nathaniel
    Terragni, Giulia
    Cala, Roberto
    Schott, Jared
    Loef, Edgar van
    Pandian, Lakshmi Soundara
    Roncali, Emilie
    Glodo, Jaroslaw
    Auffray, Etiennette
    Arino-Estrada, Gerard
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2025, 9 (03) : 296 - 303
  • [5] Time walk correction for TOF-PET detectors based on a monolithic scintillation crystal coupled to a photosensor array
    Vinke, R.
    Lohner, H.
    Schaart, D. R.
    van Dam, H. T.
    Seifert, S.
    Beekman, F. J.
    Dendooven, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 595 - 604
  • [6] Performance Characterization of MPPC Modules for TOF-PET Applications
    Goertzen, Andrew L.
    Van Elburg, Devin
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2019, 3 (04) : 475 - 482
  • [7] Thick monolithic scintillation crystals for TOF-PET with depth-of-interaction measurement
    Vinke, Ruud
    van Dam, Herman T.
    Seifert, Stefan
    Beekman, Freek J.
    Lohner, Herbert
    Schaart, Dennis R.
    Dendooven, Peter
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1981 - 1984
  • [8] Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET
    Cates, Joshua W.
    Choong, Woon-Seng
    Brubaker, Erik
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (04):
  • [9] Time rectification system for in-beam TOF-PET
    Chen, Jin-Da
    Xu, Hu-Shan
    Chen, Ruo-Fu
    Hu, Zheng-Guo
    Tang, Bin
    Wu, Da-Peng
    Yue, Ke
    Yu, Yu-Hong
    Zhang, Xue-Heng
    Kong, Jie
    Ye, Rui-Ping
    Wang, Jian-Song
    Zhang, Xue-Ying
    Guo, Zhong-Yan
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2011, 45 (01): : 97 - 101
  • [10] Optimized TOF-PET detector using scintillation crystal array for brain imaging
    Leem, Hyuntae
    Choi, Yong
    Jung, Jiwoong
    Park, Kuntai
    Kim, Yeonkyeong
    Jung, Jin Ho
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (07) : 2592 - 2598