Scanning electron microscopic evaluation of the effects of an air-abrasive system on dental implants: A comparative in vitro study between machined and plasma-sprayed titanium surfaces

被引:23
作者
Chairay, JP
Boulekbache, H
Jean, A
Soyer, A
Bouchard, P
机构
[1] Denis Diderot Univ, Sch Dent, Dept Periodontol, Paris, France
[2] Dev Biol Lab, Paris, France
[3] Mineral Crystallog Lab, Paris, France
关键词
titanium; dental implants; air abrasion; comparison study;
D O I
10.1902/jop.1997.68.12.1215
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AN LN VITRO COMPARATIVE study was conducted in order to evaluate the effects of an air-abrasive system on dental implant surfaces. Eight new titanium dental implants, four standard machined implants (machined group), and four standard plasma-sprayed implants (plasma-sprayed group) were selected for investigation. Both neck and body surfaces of the implants were analyzed. Each pair of implants in each, group was treated as follows: the spray of the air-abrasive unit was applied to each area for 5 seconds on the first implant and 15 seconds on the second implant. A total of 24 areas were observed: 16 test implants and 8 controls. Scanning electron photomicrographs were analyzed by 3 examiners using a category rating scale (kappa = 0.594). The images were also computerized for texture analysis. The results indicate that a single air-powder abrasive treatment of the dental implants selected for this study modified their exposed surfaces. After treatment, the threaded neck surface of a machined group implant was least affected, whereas the body was the most altered. In the plasma-sprayed group, comparisons between implant surfaces showed little change. In the machined group, more change was observed in both neck and body areas. In all specimens, a 5-second exposure to the air-powder abrasive did not induce deep changes in the surfaces. A 15-second exposure modified all the specimen surfaces. Further studies are needed to evaluate the effect of these changes on the biological osseointegration process.
引用
收藏
页码:1215 / 1222
页数:8
相关论文
共 26 条
  • [1] ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
  • [2] Alcoforado G A, 1991, J Parodontol, V10, P11
  • [3] Barnes C M, 1991, Int J Oral Maxillofac Implants, V6, P463
  • [4] BECKER W, 1990, International Journal of Oral and Maxillofacial Implants, V5, P31
  • [5] Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
  • [6] BRANEMARK P I, 1969, Scandinavian Journal of Plastic and Reconstructive Surgery, V3, P81
  • [7] CONTAMINATED IMPLANT SURFACES - AN IN-VITRO COMPARISON OF IMPLANT SURFACE COATING AND TREATMENT MODALITIES FOR DECONTAMINATION
    DENNISON, DK
    HUERZELER, MB
    QUINONES, C
    CAFFESSE, RG
    [J]. JOURNAL OF PERIODONTOLOGY, 1994, 65 (10) : 942 - 948
  • [8] Gonzales RafaelC., 1987, DIGITAL IMAGE PROCES, VSecond
  • [9] EFFECT OF HYGIENE INSTRUMENTATION ON TITANIUM ABUTMENTS - A SCANNING ELECTRON-MICROSCOPY STUDY
    HOMIAK, AW
    COOK, PA
    DEBOER, J
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (03) : 364 - 369
  • [10] Digital image ratio: A new radiographic method for quantifying changes in alveolar bone .1. Theory and methodology
    Jean, A
    Epelboin, Y
    Rimsky, A
    Soyer, A
    Ouhayoun, JP
    [J]. JOURNAL OF PERIODONTAL RESEARCH, 1996, 31 (03) : 161 - 167