A SCR crowbar commutated with power converter for DFIG-based wind turbines

被引:37
作者
Yang, Shuying [1 ]
Zhou, Tianbao [1 ]
Sun, Dengyue [1 ]
Xie, Zhen [1 ]
Zhang, Xing [1 ]
机构
[1] Hefei Univ Technol, Sch Elect Engn & Automat, Hefei, Peoples R China
基金
中国国家自然科学基金;
关键词
Commutation; Doubly fed induction generator (DFIG); SCR crowbar; Low voltage ride through (LVRT); Wind turbines; FED INDUCTION GENERATOR; RIDE;
D O I
10.1016/j.ijepes.2016.01.039
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an active crowbar, constructed with silicon controlled rectifiers (SCRs), for doubly fed induction generator (DFIG)-based wind turbines to fulfill low-voltage ride-through (LVRT) requirements demanded by grid codes. By this design, not only the active deactivation of the costly IGBT crowbar, replacing the passive crowbar for this ability, can be achieved with the more cost-effective SCRs, but also the reliability of the circuit is strengthened thanking to the high surge capability of SCR. In this topology, three back-to-back SCR switches are connected in delta form and further engaged with the rotor circuit of DFIG through power dissipation resistors, working as the main circuit of crowbar, while the rotor side converter (RSC) is used to commutate the SCRs at the desired deactivation moment to disconnect the crowbar, allowing for resumption of the feedback control to DFIG. By this topology the harmonics introduced into the rotor circuit by the diode bride in the IGBT crowbar are got rid of and by this commutation method the overvoltage risk at turning off the IGBT is eliminated. With the simulative results on a 2 MW DFIG, the comparison with the IGBT crowbar is made. The feasibility of the proposed crowbar technique is further demonstrated with experiments on a laboratory-scale test rig. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:87 / 103
页数:17
相关论文
共 26 条
[11]   Short-circuit current of wind turbines with doubly fed induction generator [J].
Morren, Johan ;
de Haan, Sjoerd W. H. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) :174-180
[12]  
Niiranen J, 2004, P NORD WIND POW C MA
[13]   Minimum-Threshold Crowbar for a Fault-Ride-Through Grid-Code-Compliant DFIG Wind Turbine [J].
Pannell, Graham ;
Atkinson, David J. ;
Zahawi, Bashar .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (03) :750-759
[14]  
Riyaz A., 2009, INT J ENG SCI TECHNO, V1, P90, DOI [10.4314/ijest.v1i1.58064, DOI 10.4314/IJEST.V1I1.58064]
[15]  
Sava GN, 2014, INT C HARMON QUAL PO, P669, DOI 10.1109/ICHQP.2014.6842860
[16]   Single-Phase DC Crowbar Topologies for Low Voltage Ride Through Fulfillment of High-Power Doubly Fed Induction Generator-Based Wind Turbines [J].
Vidal, Jon ;
Abad, Gonzalo ;
Arza, Joseba ;
Aurtenechea, Sergio .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2013, 28 (03) :768-781
[17]  
WANG MZ, 2012, P IND EL ISIE, P957
[18]   Fault Ride Through of DFIG Wind Turbines during symmetrical voltage dip with Crowbar or Stator Current Feedback Solution [J].
Wessels, Christian ;
Fuchs, Friedrich W. .
2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, :2771-2777
[19]   Control of a doubly fed induction generator in a wind turbine during grid fault ride-through [J].
Xiang, Dawei ;
Ran, Li ;
Tavner, Peter J. ;
Yang, Shunchang .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (03) :652-662
[20]   An LVRT Control Strategy Based on Flux Linkage Tracking for DFIG-Based WECS [J].
Xiao, Shuai ;
Yang, Geng ;
Zhou, Honglin ;
Geng, Hua .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (07) :2820-2832