Pilot plant experimental studies of post combustion CO2 capture by reactive absorption with MEA and new solvents

被引:122
|
作者
Mangalapally, Hari Prasad [1 ]
Notz, Ralf [2 ,3 ]
Hoch, Sebastian [1 ]
Asprion, Norbert [3 ]
Sieder, Georg [3 ]
Garcia, Hugo [3 ]
Hasse, Hans [1 ]
机构
[1] Tech Univ Kaiserslautern, LTD, Kaiserslautern, Germany
[2] Univ Stuttgart, ITT, Stuttgart, Germany
[3] BASF SE, Ludwigshafen, Germany
来源
关键词
CO2; capture; Reactive absorption; Desorption; Flue gas; Amines; Rate-based model; Simulations; New solvents; ENERGY-SAVING TECHNOLOGY; CARBON-DIOXIDE RECOVERY; STEAM SYSTEM; POWER-PLANT; MONOETHANOLAMINE; HEAT;
D O I
10.1016/j.egypro.2009.01.128
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The main challenge for the CO2 post combustion capture from power plant flue gases is the reduction of the energy requirement for solvent regeneration. The required reduction can only be achieved by application of new solvents. For the validation of new solvents in the absorption/desorption process, a pilot plant (column diameters 0.125 m, absorber packing height 4.2 m, flue gas flow 30-110 kg/h, CO2 partial pressure 35-135 mbar) was built in the EU-project CASTOR. To obtain a baseline for testing of new solvents, first systematic studies were carried out with MEA in that plant. All important process parameters, i.e. CO2 content in the flue gas, CO2 removal rate Psi(CO2), fluid dynamic load, and solvent flow rate were varied. These studies allow detailed insight into the process, e. g., a quantification of the different contributions to the overall regeneration energy (namely: desorption enthalpy, stripping steam, heating up of solvent feed and condensate recycle) as a function of the chosen process parameters. A rate-based model of the process based on a detailed physico-chemical model was implemented in the process simulator CHEMASIM. It is shown that the model is able to predict the experimental results for MEA. Besides MEA, two new solvents were studied in the pilot plant. A direct comparison of different solvents in such pilot plant experiments is not trivial. The comparison of only a few operating points for the new solvents with seemingly corresponding results for MEA can lead to wrong conclusions, since for each solvent an optimisation of the operating conditions is necessary. Only systematical studies allow a meaningful comparison. The technique that was used in the present work for this purpose was measuring data sets at constant CO2 removal rate (by adjustment of the regeneration energy in the desorber) and systematically varying the solvent flow rate. A minimal energy requirement for the given removal rate is found from theses studies. Only the optima for different solvents should be compared. By this procedure, one solvent candidate was identified that shows an advantage compared to MEA. (c) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:963 / 970
页数:8
相关论文
共 50 条
  • [41] Exergetic and exergoeconomic analysis of post-combustion CO2 capture using MEA-solvent chemical absorption
    Ferrara, G.
    Lanzini, A.
    Leone, P.
    Ho, M. T.
    Wiley, D. E.
    ENERGY, 2017, 130 : 113 - 128
  • [42] Dynamic Validation of Model for Post-Combustion Chemical Absorption CO2 Capture Plant
    Biliyok, Chechet
    Lawal, Adekola
    Wang, Meihong
    Seibert, Frank
    22 EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2012, 30 : 807 - 811
  • [43] Development of catalysts for fast, energy efficient post combustion capture of CO2 into water; an alternative to monoethanolamine (MEA) solvents.
    Davy, Raymond
    GREENHOUSE GAS CONTROL TECHNOLOGIES 9, 2009, 1 (01): : 885 - 892
  • [44] Environmental risk assessment of MEA and its degradation products from Post-Combustion CO2 Capture Pilot Plant: Drafting technical guidelines
    Kimura, Hajime
    Kubo, Toshiaki
    Shimada, Masatoshi
    Kitamura, Hideo
    Fujita, Koshito
    Suzuki, Kensuke
    Yamamoto, Kenji
    Akai, Makoto
    13TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-13, 2017, 114 : 6490 - 6500
  • [45] Post-combustion CO2 capture process: Equilibrium stage mathematical model of the chemical absorption of CO2 into monoethanolamine (MEA) aqueous solution
    Mores, Patricia
    Scenna, Nicolas
    Mussati, Sergio
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (09): : 1587 - 1599
  • [46] Comparison of absorption rates and absorption capacity of ammonia solvents with MEA and MDEA aqueous blends for CO2 capture
    Rivera-Tinoco, Rodrigo
    Bouallou, Chakib
    JOURNAL OF CLEANER PRODUCTION, 2010, 18 (09) : 875 - 880
  • [47] Experimental approach to mimic and study degradation of solvents used for post-combustion CO2 capture
    Bontemps, D.
    Cuccia, L.
    Awad, P.
    Louis-Louisy, M.
    Vial, J.
    Dugay, J.
    Carrette, P. L.
    Huard, T.
    Morand, T.
    13TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-13, 2017, 114 : 1709 - 1715
  • [48] Modelling reactive absorption of CO2 in packed columns for post-combustion carbon capture applications
    Khan, F. M.
    Krishnamoorthi, V.
    Mahmud, T.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (09): : 1600 - 1608
  • [49] Design of energy efficient reactive solvents for post combustion CO2 capture using computer aided approach
    Ahmad, Muhammad Zulhilmi
    Hashim, Haslenda
    Mustaffa, Azizul Azri
    Maarof, Hasmerya
    Yunus, Nor Alafiza
    JOURNAL OF CLEANER PRODUCTION, 2018, 176 : 704 - 715
  • [50] Evaluation of process upgrades and novel solvents for the post combustion CO2 capture process in pilot-scale
    Knudsen, Jacob N.
    Andersen, Jimmy
    Jensen, Jorgen N.
    Biede, Ole
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 1558 - 1565