Pilot plant experimental studies of post combustion CO2 capture by reactive absorption with MEA and new solvents

被引:123
作者
Mangalapally, Hari Prasad [1 ]
Notz, Ralf [2 ,3 ]
Hoch, Sebastian [1 ]
Asprion, Norbert [3 ]
Sieder, Georg [3 ]
Garcia, Hugo [3 ]
Hasse, Hans [1 ]
机构
[1] Tech Univ Kaiserslautern, LTD, Kaiserslautern, Germany
[2] Univ Stuttgart, ITT, Stuttgart, Germany
[3] BASF SE, Ludwigshafen, Germany
来源
GREENHOUSE GAS CONTROL TECHNOLOGIES 9 | 2009年 / 1卷 / 01期
关键词
CO2; capture; Reactive absorption; Desorption; Flue gas; Amines; Rate-based model; Simulations; New solvents; ENERGY-SAVING TECHNOLOGY; CARBON-DIOXIDE RECOVERY; STEAM SYSTEM; POWER-PLANT; MONOETHANOLAMINE; HEAT;
D O I
10.1016/j.egypro.2009.01.128
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The main challenge for the CO2 post combustion capture from power plant flue gases is the reduction of the energy requirement for solvent regeneration. The required reduction can only be achieved by application of new solvents. For the validation of new solvents in the absorption/desorption process, a pilot plant (column diameters 0.125 m, absorber packing height 4.2 m, flue gas flow 30-110 kg/h, CO2 partial pressure 35-135 mbar) was built in the EU-project CASTOR. To obtain a baseline for testing of new solvents, first systematic studies were carried out with MEA in that plant. All important process parameters, i.e. CO2 content in the flue gas, CO2 removal rate Psi(CO2), fluid dynamic load, and solvent flow rate were varied. These studies allow detailed insight into the process, e. g., a quantification of the different contributions to the overall regeneration energy (namely: desorption enthalpy, stripping steam, heating up of solvent feed and condensate recycle) as a function of the chosen process parameters. A rate-based model of the process based on a detailed physico-chemical model was implemented in the process simulator CHEMASIM. It is shown that the model is able to predict the experimental results for MEA. Besides MEA, two new solvents were studied in the pilot plant. A direct comparison of different solvents in such pilot plant experiments is not trivial. The comparison of only a few operating points for the new solvents with seemingly corresponding results for MEA can lead to wrong conclusions, since for each solvent an optimisation of the operating conditions is necessary. Only systematical studies allow a meaningful comparison. The technique that was used in the present work for this purpose was measuring data sets at constant CO2 removal rate (by adjustment of the regeneration energy in the desorber) and systematically varying the solvent flow rate. A minimal energy requirement for the given removal rate is found from theses studies. Only the optima for different solvents should be compared. By this procedure, one solvent candidate was identified that shows an advantage compared to MEA. (c) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:963 / 970
页数:8
相关论文
共 8 条
[1]   CO2 capture from power plants.: Part I.: A parametric study of the technical-performance based on monoethanolamine [J].
Abu-Zahra, Mohammad R. M. ;
Schneiders, Leon H. J. ;
Niederer, John P. M. ;
Feron, Paul H. M. ;
Versteeg, Geert F. .
INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2007, 1 (01) :37-46
[2]   Nonequilibrium rate-based simulation of reactive systems: Simulation model, heat transfer, and influence of film discretization [J].
Asprion, N .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (06) :2054-2069
[3]  
*EUR COMM, CASTOR CO2 CAPT STOR
[4]   Heat of absorption of carbon dioxide (CO2) in monoethanolamine (MEA) and 2-(Aminoethyl)ethanolamine (AEEA) solutions [J].
Kim, Inna ;
Svendsen, Hallvard F. .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2007, 46 (17) :5803-5809
[5]   Development of energy saving technology for flue gas carbon dioxide recovery in power plant by chemical absorption method and steam system [J].
Mimura, T ;
Simayoshi, H ;
Suda, T ;
Iijima, M ;
Mituoka, S .
ENERGY CONVERSION AND MANAGEMENT, 1997, 38 :S57-S62
[6]   RESEARCH-AND-DEVELOPMENT ON ENERGY-SAVING TECHNOLOGY FOR FLUE-GAS CARBON-DIOXIDE RECOVERY AND STEAM SYSTEM IN POWER-PLANT [J].
MIMURA, T ;
SHIMOJO, S ;
SUDA, T ;
IIJIMA, M ;
MITSUOKA, S .
ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (6-9) :397-400
[7]  
Notz R, 2007, CHEM ENG RES DES, V85, P510, DOI [10.1205/cherd06085, 10.1205/cherd.06085]
[8]  
NOTZ R, 2009, THESIS U STUTTGART G