A Virtual Monochromatic Imaging Method for Spectral CT Based on Wasserstein Generative Adversarial Network With a Hybrid Loss

被引:10
作者
Shi, Zaifeng [1 ]
Li, Jinzhuo [1 ]
Li, Huilong [1 ]
Hu, Qixing [1 ]
Cao, Qingjie [2 ]
机构
[1] Tianjin Univ, Sch Microelect, Tianjin 300072, Peoples R China
[2] Tianjin Normal Univ, Sch Math Sci, Tianjin 300387, Peoples R China
基金
中国国家自然科学基金;
关键词
Spectral CT; generative adversarial network; monochromatic imaging; hybrid loss; DUAL-ENERGY CT; LOW-DOSE CT; MONOENERGETIC EXTRAPOLATION; COMPUTED-TOMOGRAPHY; ARTIFACT REDUCTION; RECONSTRUCTION; ALGORITHM;
D O I
10.1109/ACCESS.2019.2934508
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Spectral computed tomography (CT) has become a popular clinical diagnostic technique because of its unique advantage in material distinction. Specifically, it can perform virtual monochromatic imaging to obtain accurate tissue composition with less beam hardening artifacts. It is an ill-posed problem that monochromatic images are acquired by material decomposition matrix, suffering from amplified noise due to various uncertain factors. Aiming at modeling spatial and spectral correlations, this paper proposes a Wasserstein generative adversarial network with a hybrid loss (WGAN-HL) for monochromatic imaging instead of voxel-by-voxel decomposition. A min-max concept about the optimal transport is introduced in WGAN to make a tradeoff between generated images and target images where the authenticity of data cannot be distinguished anymore by network. The hybrid loss focuses on the data distribution of the generated images and target images from voxel space together with feature space to meet clinical requirements. Thereby, the proposed network can generate robust monochromatic images with accurate decomposition at any energy, while identifying and removing noise and artifacts. The advantages of this method are demonstrated in CT value measurement, beam hardening, and metal artifacts removal. Simulations and real tests prove that the WGAN-HL method preserves the important tissue details with less noise and it can reconstruct more accurate CT value. Both qualitative and quantitative comparisons show that the network is superior to other monochromatic imaging method.
引用
收藏
页码:110992 / 111011
页数:20
相关论文
共 56 条
[1]  
Abadi M., 2015, TENSORFLOW LARGE SCA, DOI DOI 10.48550/ARXIV.1603.04467
[2]  
[Anonymous], P 3 INT C LEARNING R
[3]  
[Anonymous], 2012, P NIPS
[4]  
[Anonymous], 2017, ARXIV170107875
[5]  
[Anonymous], 2017, P IEEE C COMP VIS PA, DOI DOI 10.1109/CVPR.2017.19
[6]  
[Anonymous], 2017, ARXIV170100160
[7]  
[Anonymous], 2017, ADV NEURAL INFORM PR
[8]   Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography [J].
Apfaltrer, Paul ;
Sudarski, Sonja ;
Schneider, David ;
Nance, John W., Jr. ;
Haubenreisser, Holger ;
Fink, Christian ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :322-328
[9]   Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging [J].
Beeres, Martin ;
Trommer, Jesko ;
Frellesen, Claudia ;
Nour-Eldin, Nour-Eldin A. ;
Scholtz, Jan E. ;
Herrmann, Eva ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (01) :137-144
[10]   Renal Stone Assessment with Dual-Energy Multidetector CT and Advanced Postprocessing Techniques: Improved Characterization of Renal Stone Composition-Pilot Study [J].
Boll, Daniel T. ;
Patil, Neil A. ;
Paulson, Erik K. ;
Merkle, Elmar M. ;
Simmons, W. Neal ;
Pierre, Sean A. ;
Preminger, Glenn M. .
RADIOLOGY, 2009, 250 (03) :813-820