Metabolite-selective hyperpolarized 13C imaging using extended chemical shift displacement at 9.4 T

被引:9
作者
Yang, Seungwook [1 ]
Lee, Joonsung [2 ]
Joe, Eunhae [1 ]
Lee, Hansol [1 ]
Choi, Young-Suk [3 ]
Park, Jae Mo [4 ]
Spielman, Daniel [4 ]
Song, Ho-Taek [3 ]
Kim, Dong-Hyun [1 ]
机构
[1] Yonsei Univ, Dept Elect & Elect Engn, Engn Hall 3,Room C228, Seoul 120749, South Korea
[2] Sungkyunkwan Univ, Inst Basic Sci, Ctr Neurosci Imaging Res, Suwon, South Korea
[3] Yonsei Univ, Coll Med, Dept Radiol, Seoul, South Korea
[4] Stanford Univ, Lucas MRI Ctr, Dept Radiol, Stanford, CA 94305 USA
关键词
Hyperpolarized; C-13; Metabolic imaging; Chemical shift displacement; 9.4; T; MULTIBAND EXCITATION PULSES; GRADIENT REVERSAL TECHNIQUE; MAGNETIC-RESONANCE; IN-VIVO; PYRUVATE; BICARBONATE; HEART; NMR; MRI;
D O I
10.1016/j.mri.2015.12.023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a technique for frequency-selective hyperpolarized C-13 metabolic imaging in ultra-high field strength which exploits the broad spatial chemical shift displacement in providing spectral and spatial selectivity. Methods: The spatial chemical shift displacement caused by the slice-selection gradient was utilized in acquiring metabolite-selective images. Interleaved images of different metabolites were acquired by reversing the polarity of the slice-selection gradient at every repetition time, while using a low-bandwidth radio-frequency excitation pulse to altematingly shift the displaced excitation bands outside the imaging subject Demonstration of this technique is presented using H-1 phantom and in vivo mouse renal hyperpolarized C-13 imaging experiments with conventional chemical shift imaging and fast low-angle shot sequences. Results: From phantom and in vivo mouse studies, the spectral selectivity of the proposed method is readily demonstrated using results of chemical shift spectroscopic imaging, which displayed clearly delineated images of different metabolites. Imaging results using the proposed method without spectral encoding also showed effective separation while also providing high spatial resolution. Conclusion: This method provides a way to acquire spectrally selective hyperpolarized C-13 metabolic images in a simple implementation, and with potential ability to support combination with more elaborate readout methods for faster imaging. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:535 / 540
页数:6
相关论文
共 28 条
[1]   Increase in signal-to-noise ratio of >10,000 times in liquid-state NMR [J].
Ardenkjaer-Larsen, JH ;
Fridlund, B ;
Gram, A ;
Hansson, G ;
Hansson, L ;
Lerche, MH ;
Servin, R ;
Thaning, M ;
Golman, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (18) :10158-10163
[2]  
Bernstein M.A., 2004, HDB MRI PULSE SEQUEN, P319
[3]   Hyperpolarized c-13 spectroscopic imaging of the TRAMP mouse at 3T - Initial experience [J].
Chen, Albert P. ;
Albers, Mark J. ;
Cunningham, Charles H. ;
Kohler, Susan J. ;
Yen, Yi-Fen ;
Hurd, Ralph E. ;
Tropp, James ;
Bok, Robert ;
Pauly, John M. ;
Nelson, Sarah J. ;
Kurhanewicz, John ;
Vigneron, Daniel B. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) :1099-1106
[4]   Magnetic resonance imaging with hyperpolarized [1,4-13C2]fumarate allows detection of early renal acute tubular necrosis [J].
Clatworthy, Menna R. ;
Kettunen, Mikko I. ;
Hu, De-En ;
Mathews, Rebeccah J. ;
Witney, Timothy H. ;
Kennedy, Brett W. C. ;
Bohndiek, Sarah E. ;
Gallagher, Ferdia A. ;
Jarvis, Lorna B. ;
Smith, Kenneth G. C. ;
Brindle, Kevin M. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (33) :13374-13379
[5]   Double spin-echo sequence for rapid spectroscopic imaging of hyperpolarized 13C [J].
Cunningham, Charles H. ;
Chen, Albert P. ;
Albers, Mark J. ;
Kurhanewicz, John ;
Hurd, Ralph E. ;
Yen, Yi-Fen ;
Pauly, John M. ;
Nelson, Sarah J. ;
Vigneron, Daniel B. .
JOURNAL OF MAGNETIC RESONANCE, 2007, 187 (02) :357-362
[6]   Detecting tumor response to treatment using hyperpolarized 13C magnetic resonance imaging and spectroscopy [J].
Day, Sam E. ;
Kettunen, Mikko I. ;
Gallagher, Ferdia A. ;
Hu, De-En ;
Lerche, Mathilde ;
Wolber, Jan ;
Golman, Klaes ;
Ardenkjaer-Larsen, Jan Henrik ;
Brindle, Kevin M. .
NATURE MEDICINE, 2007, 13 (11) :1382-1387
[7]   Magnetic resonance imaging of pH in vivo using hyperpolarized 13C-labelled bicarbonate [J].
Gallagher, Ferdia A. ;
Kettunen, Mikko I. ;
Day, Sam E. ;
Hu, De-En ;
Ardenkjær-Larsen, Jan Henrik ;
in't Zandt, Rene ;
Jensen, Pernille R. ;
Karlsson, Magnus ;
Golman, Klaes ;
Lerche, Mathilde H. ;
Brindle, Kevin M. .
NATURE, 2008, 453 (7197) :940-U73
[8]   Molecular imaging with endogenous substances [J].
Golman, K ;
Ardenær-Larsen, JH ;
Petersson, JS ;
Månsson, S ;
Leunbach, I .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (18) :10435-10439
[9]   Cardiac metabolism measured noninvasively by hyperpolarized 13C MRI [J].
Golman, Klaes ;
Petersson, J. Stefan ;
Magnusson, Peter ;
Johansson, Edvin ;
Akeson, Per ;
Chai, Chun-Ming ;
Hansson, Georg ;
Mansson, Sven .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) :1005-1013
[10]   Metabolic imaging by hyperpolarized 13C magnetic resonance imaging for in vivo tumor diagnosis [J].
Golman, Klaes ;
in't Zandt, Rene ;
Lerche, Mathilde ;
Pehrson, Rikard ;
Ardenkjaer-Larsen, Jan Henrik .
CANCER RESEARCH, 2006, 66 (22) :10855-10860