A hybrid renewable energy system for a North American off-grid community

被引:100
作者
Rahman, Md Mustafizur [1 ]
Khan, Md Mohib-Ul-Haque [1 ]
Ullah, Mohammad Ahsan [1 ]
Zhang, Xiaolei [1 ]
Kumar, Amit [1 ]
机构
[1] Univ Alberta, Dept Mech Engn, Donadeo Innovat Ctr Engn, Edmonton, AB T6G 1H9, Canada
关键词
Hybrid energy system; HOMER; Off-grid; Renewable energy; TECHNOECONOMIC ANALYSIS; POWER-SYSTEM; RURAL ELECTRIFICATION; PV-SOLAR; FEASIBILITY; WIND; GENERATION; MALAYSIA; TURBINE; ISLAND;
D O I
10.1016/j.energy.2015.12.105
中图分类号
O414.1 [热力学];
学科分类号
摘要
Canada has many isolated communities that are not connected to the electrical grid. Most of these communities meet their electricity demand through stand-alone diesel generators. Diesel generators have economic and environmental concerns that can be minimized by using hybrid renewable energy technologies. This study aims to assess the implementation of a hybrid energy system for an off-grid community in Canada and to propose the best hybrid energy combination to reliably satisfy electricity demand. Seven scenarios were developed: 1) 100% renewable resources, 2) 80% renewable resources, 3) 65% renewable resources, 4) 50% renewable resources, 5) 35% renewable resources, 6) 21% renewable resources, and 7) battery-diesel generators (0% renewable resources). A case study for the remote community of Sandy Lake, Ontario, was conducted. Hybrid systems were chosen to meet the requirements of a 4.4 MWh/day primary load with a 772 kW peak load. Sensitivity analyses were carried out to assess the impact of solar radiation, wind speed, diesel price, CO2 penalty cost, and project interest rate on optimum results. A GHG (greenhouse gas) abatement cost was assessed for each scenario. Considering GHG emission penalty cost, the costs of electricity for the seven scenarios are $1.48/kWh, $0.62/kWh, $0.54/kWh, $0.42/kWh, $0.39/kWh, $0.37/kWh, and $0.36/kWh. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:151 / 160
页数:10
相关论文
共 28 条
[1]   Analysis of hybrid energy systems for application in southern Ghana [J].
Adaramola, Muyiwa S. ;
Agelin-Chaab, Martin ;
Paul, Samuel S. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 88 :284-295
[2]   Assessment of decentralized hybrid PV solar-diesel power system for applications in Northern part of Nigeria [J].
Adaramola, Muyiwa S. ;
Paul, Samuel S. ;
Oyewola, Olanrewaju M. .
ENERGY FOR SUSTAINABLE DEVELOPMENT, 2014, 19 :72-82
[3]   Hybrid renewable energy systems for power generation in stand-alone applications: A review [J].
Bajpai, Prabodh ;
Dash, Vaishalee .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (05) :2926-2939
[4]  
Bank of Canada, 2015, INFL CALC
[5]  
Better Generation, REDRIVEN 10 KW WIND
[6]   Feasibility analysis of stand-alone renewable energy supply options for a large hotel [J].
Dalton, G. J. ;
Lockington, D. A. ;
Baldock, T. E. .
RENEWABLE ENERGY, 2008, 33 (07) :1475-1490
[7]   Modeling of hybrid renewable energy systems [J].
Deshmukh, M. K. ;
Deshmukh, S. S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2008, 12 (01) :235-249
[8]  
Environment Canada, CAN WIND EN ATL
[9]   Optimum design of hybrid renewable energy systems: Overview of different approaches [J].
Erdinc, O. ;
Uzunoglu, M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (03) :1412-1425
[10]   Multi-objective optimization of a stand-alone hybrid renewable energy system by using evolutionary algorithms: A review [J].
Fadaee, M. ;
Radzi, M. A. M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (05) :3364-3369