On-site measurement of tracer gas transmission between horizontal adjacent flats in residential building and cross-infection risk assessment

被引:41
|
作者
Wu, Yan [1 ]
Tung, Thomas C. W. [1 ]
Niu, Jian-lei [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
Airborne transmission; Infection risk; On-site measurement; Tracer gas; Air infiltration; Residential building; AIRBORNE TRANSMISSION; POLLUTANT DISPERSION; VENTILATION RATES; BUILT ENVIRONMENT; ISOLATION ROOM; AIR-FLOW; SIMULATION; CONTAMINATION; PENETRATION; DEPOSITION;
D O I
10.1016/j.buildenv.2016.01.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Airborne transmission is a main spread mode of respiratory infectious diseases, whose frequent epidemic has brought serious social burden. Identifying possible routes of the airborne transmission and predicting the potential infection risk are meaningful for infectious disease control. In the present study, an internal spread route between horizontal adjacent flats induced by air infiltration was investigated. On site measurements were conducted, and tracer gas technique was employed. Two measurement scenarios, closed window mode and open window mode, were compared. Using the calculated air change rate and mass fraction, the cross-infection risk was estimated using the Wells Riley model. It found that tracer gas concentrations in receptor rooms are one order lower than the source room, and the infection risks are also one order lower. Opening windows results in larger air change rate on the one hand, but higher mass fraction on the other hand. Higher mass fraction not necessarily results in higher infection risk as the pathogen concentration in the source room is reduced by the higher air change rate. In the present study, opening windows could significantly reduce the infection risk of the index room but slightly reduce the risks in receptor rooms. The mass fraction of air originated from the index room to the receptor units could be 0.28 and the relative cross-infection risk through the internal transmission route could be 9%, which are higher than the external spread through single-sided window flush. The study implicates that the horizontal transmission route induced by air infiltration should not be underestimated. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 3 条
  • [1] The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation
    Gao, N. P.
    Niu, J. L.
    Perino, M.
    Heiselberg, P.
    BUILDING AND ENVIRONMENT, 2008, 43 (11) : 1805 - 1817
  • [2] Onsite measurement and dilution-based infection risk assessment for a new mobile negative pressure isolation room (MNPIR) as a solution to minimize cross-infection
    Cho, Jinkyun
    Jang, Seungmin
    Song, Jongwoon
    SUSTAINABLE CITIES AND SOCIETY, 2023, 95
  • [3] Camera-based occupant behavior trajectory capture and on-site assessment of spatio-temporal transmission risk of airborne virus in a university office building
    Zhong, Zhitao
    Pan, Zhenyu
    Tang, Haida
    Wang, Junjie
    Liu, Fang
    Wang, Jingwei
    BUILDING AND ENVIRONMENT, 2023, 243