Nodal Sensitivity-Based Smart Inverter Control for Voltage Regulation in Distribution Feeder

被引:20
|
作者
Ceylan, Oguzhan [1 ]
Paudyal, Sumit [2 ]
Pisica, Ioana [3 ]
机构
[1] Kadir Has Univ, TR-34083 Istanbul, Turkey
[2] Florida Int Univ, Miami, FL 33199 USA
[3] Brunel Univ London, Uxbridge UB8 3PH, Middx, England
来源
IEEE JOURNAL OF PHOTOVOLTAICS | 2021年 / 11卷 / 04期
关键词
Inverters; Reactive power; Voltage control; Sensitivity; Voltage measurement; Reactive power control; Load modeling; Distribution grid; optimal power flow (OPF); overvoltage; photovoltaic (PV); smart inverter; voltage control; REACTIVE POWER-CONTROL; DISTRIBUTION-SYSTEMS; HIGH PENETRATION; PV INVERTERS; CURTAILMENT; NETWORKS; RISE;
D O I
10.1109/JPHOTOV.2021.3070416
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Overvoltage is one of the issues in distribution grids with high penetration of photovoltaics (PVs). Centralized or droop-based methods of active power curtailment (APC) and/or reactive power control of PVs are viable solutions to prevent overvoltage. This article proposes two distributed methods to control PV inverters, which are based on nodal sensitivities. Then, the performance of the proposed methods is compared with two commonly used control methods, i.e., a distributed method that follows IEEE-1547 but uses arbitrarily chosen droops and a centralized optimal power flow (OPF) based method. Performance is evaluated using a 730-node feeder with up to 100% penetration of inverters. Based on the case studies, the key findings are: first, local droop setting as per IEEE-1547, whether the droops are arbitrarily chosen or systematically calculated using sensitivities, can eliminate overvoltage if reactive power control and APC are coordinated, second, the proposed sensitivity-based approach yields the best voltage performance index computed based on voltage profile compared to the maximum allowed upper bound, and third, OPF-based method is desirable if communication infrastructure exists and minimum energy curtailment is sought.
引用
收藏
页码:1105 / 1113
页数:9
相关论文
共 50 条
  • [41] A Study on Analysis of Voltage Recovery Impact of Smart Inverter Based on Distribution System Characteristics
    Gwon D.-Y.
    Choi Y.-H.
    Transactions of the Korean Institute of Electrical Engineers, 2024, 73 (07): : 1112 - 1118
  • [42] A benchmark model for low voltage distribution networks with PV systems and smart inverter control techniques
    Ibrahim, Ibrahim Anwar
    Hossain, M. J.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 166
  • [43] High-Speed Voltage Control in Active Distribution Systems with Smart Inverter Coordination and DRL
    Golgol, Mohammad
    Pal, Anamitra
    2024 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, PESGM 2024, 2024,
  • [44] Sensitivity-based coordination in distributed model predictive control
    Scheu, Holger
    Marquardt, Wolfgang
    JOURNAL OF PROCESS CONTROL, 2011, 21 (05) : 715 - 728
  • [45] Feeder Voltage Management through Smart Inverter Advanced Functions and Battery Energy Storage System
    Nassif, Alexandre B.
    Greenwood-Madsen, Tom
    Azad, Sahar Pirooz
    Teshome, Dawit F.
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [46] Voltage Control Strategy of Distribution Network based on Coordinated Control of PV Inverter and SVG
    Wu, Xiaofei
    Dai, Hui
    Xu, Zikun
    Lu, Yongcan
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 1907 - 1911
  • [47] Voltage Sensitivity-Based Transient Voltage Stability Analysis Considering HVDC Recovery Characteristics
    Chen, Peidong
    Du, Zhaobin
    Zhan, Fujun
    Zhang, Yao
    TENCON 2015 - 2015 IEEE REGION 10 CONFERENCE, 2015,
  • [48] Sensitivity-Based Impedance Modeling of AC Voltage-Controlled Converters
    Perez-Estevez, Diego
    Rios-Castro, Diego
    Doval-Gandoy, Jesus
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (05) : 7125 - 7137
  • [49] Sensitivity-based hybrid approach for voltage instability alleviation using ANN
    Electrical Engineering Department, National Institute of Technology, Hamirpur 177 005, India
    不详
    Int J Power Energy Syst, 2007, 1 (13-20):
  • [50] Sensitivity-based feedforward and feedback control for uncertain systems
    Andreas Rauh
    Julia Kersten
    Ekaterina Auer
    Harald Aschemann
    Computing, 2012, 94 : 357 - 367