Factors influencing resonance frequency analysis assessed by Osstell™mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length

被引:132
作者
Sim, Christina P. C. [2 ]
Lang, Niklaus P. [1 ]
机构
[1] Univ Hong Kong, Prince Philip Hosp, Hong Kong, Hong Kong, Peoples R China
[2] Natl Dent Ctr Singapore, Dept Restorat Dent, Prosthodont Unit, Singapore, Singapore
关键词
bone structure; implant length; implant stability; instrument positioning; Osstell (TM) mentor; resonance frequency analysis; RFA; wound healing; FORMATION ADJACENT; TITANIUM IMPLANTS; STABILITY; DOG; INTERFACE;
D O I
10.1111/j.1600-0501.2009.01878.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To monitor longitudinally the development of implant stability of SLA Straumann (R) tissue-level implants using resonance frequency analysis (RFA) and to determine the influence of instrument positioning, bone structure and implant length on the assessment of RFA. Material and methods Thirty-two healthy adult patients received either 8 mm, empty set4.1 mm Straumann (R) Standard Plus tissue-level implants (n=16: Group A) or 10 mm, empty set4.1 mm Straumann (R) Standard Plus tissue-level implants (n=16: Group B). During healing, RFA was performed on Weeks 0,1, 2, 3, 4, 5, 6, 8 and 12. The implants were restored after 10 weeks (impression taking) and 12 weeks. In addition, probing depth, presence of plaque and bleeding on probing were assessed. Implant stability quotient (ISQ) values of Groups A and B were compared using unpaired t-tests and longitudinally applying paired t-tests between Week 0 and the subsequent time points. Results Positioning of the Osstell (TM) mentor device did not affect the ISQ values. Generally, ISQ values increased continuously during healing from a mean of 65.1 (SD 16.97) to 74.7 (SD 5.17) (significantly from Week 0 to Weeks 6, 8 and 12). Lower bone density (Type III or IV) resulted in significantly lower ISQ values up to Week 8. Implant length affected the increase in ISQ values over time. While no significant increase was observed with 10 mm implants, ISQ values of 8 mm implants increased significantly from Week 0 to Weeks 6, 8 and 12. Conclusions Using Osstell (TM) mentor, ISQ values are reproducible irrespective of instrument positioning. ISQ values are affected by the bone structure and implant length. Hence, no predictive values can be attributed to implant stability. To cite this article:Sim CPC, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell (TM) mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length.Clin. Oral Impl. Res. 21, 2010; 598-604.doi: 10.1111/j.1600-0501.2009.01878.x.
引用
收藏
页码:598 / 604
页数:7
相关论文
共 21 条
[1]   Early bone formation adjacent to rough and turned endosseous implant surfaces - An experimental study in the dog [J].
Abrahamsson, I ;
Berglundh, T ;
Linder, E ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :381-392
[2]   Implant stability in relation to osseointegration: an experimental study in the Labrador dog [J].
Abrahamsson, Ingemar ;
Linder, Elena ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (03) :313-318
[3]  
Adell R., 1985, TISSUE INTEGRATED PR, P211
[4]   Validity and clinical significance of biomechanical testing of implant/bone interface [J].
Aparicio, Carlos ;
Lang, Niklaus R. ;
Rangert, Bo .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 :2-7
[5]  
Balleri Piero, 2002, Clin Implant Dent Relat Res, V4, P128, DOI 10.1111/j.1708-8208.2002.tb00162.x
[6]   VARIATIONS IN ADULT CORTICAL BONE MASS AS MEASURED BY A PANORAMIC MANDIBULAR INDEX [J].
BENSON, BW ;
PRIHODA, TJ ;
GLASS, BJ .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1991, 71 (03) :349-356
[7]   De novo alveolar bone formation adjacent to endosseous implants -: A model study in the dog [J].
Berglundh, T ;
Abrahamsson, I ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (03) :251-262
[8]  
Cochran DL, 1998, J BIOMED MATER RES, V40, P1, DOI 10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO
[9]  
2-Q
[10]   Early detection of implant healing process using resonance frequency analysis [J].
Huang, HM ;
Chiu, CL ;
Yeh, CY ;
Lin, CT ;
Lin, LH ;
Lee, SY .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (04) :437-443