Comparison of extraction of a β-blocker from plasma onto a molecularly imprinted polymer with liquid-liquid extraction and solid phase extraction methods

被引:52
作者
Martin, PD
Jones, GR
Stringer, F
Wilson, ID
机构
[1] AstraZeneca Pharmaceut, Dept Drug Metab & Pharmacokinet, Macclesfield SK10 4TG, Cheshire, England
[2] Univ Keele, Sch Chem & Phys, Keele ST5 5BG, Staffs, England
[3] Celltech Grp Plc, Slough SL1 3WE, Berks, England
关键词
solid phase extraction; liquid-liquid extraction; molecularly imprinted polymers; phenyl boronic acid; plasma; beta-blockers;
D O I
10.1016/j.jpba.2004.03.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An optimised solid phase extraction (SPE) method developed for the extraction of a structural analogue of the P-blocking drug propranolol from plasma utilising a molecularly imprinted polymer (MIP) has been compared with methods based on conventional liquid-liquid extraction (LLE), and SPE using C18-bonded and immobilised phenyl boronic acid (PBA). All four methods could be used for the extraction of the analyte with acceptable accuracy and precision. The MIP-based method, unlike the other methods required a protein precipitation step prior to extraction to eliminate the effects of co-extracted protein. The best performance was seen with the LLE method followed by SPE on the C18 phase. The MIP-based method represented no advantage over the comparator methods for this analyte. Indeed the performance of the MIP-based method was marginally worse as leaching of low level template impurities prevented detection of the target analyte at low concentrations (5 ng mL(-1)). This relatively poorer performance was evident as worse accuracy at low concentrations with a consequent higher limit of quantification than the conventional methods. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1231 / 1239
页数:9
相关论文
共 21 条
[1]   Molecular imprinting for drug bioanalysis - A review on the application of imprinted polymers to solid-phase extraction and binding assay [J].
Andersson, LI .
JOURNAL OF CHROMATOGRAPHY B, 2000, 739 (01) :163-173
[2]  
Andersson LI, 2003, HANDB ANALYT SEPARAT, V4, P45
[3]   Towards molecular-imprint based SPE of local anaesthetics [J].
Andersson, LI ;
Abdel-Rehim, M ;
Nicklasson, L ;
Schweitz, L ;
Nilsson, S .
CHROMATOGRAPHIA, 2002, 55 (Suppl 1) :S65-S69
[4]   Application of molecular imprinting to the development of aqueous buffer and organic solvent based radioligand binding assays for (S)-propranolol [J].
Andersson, LI .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :111-117
[5]   A highly selective solid phase extraction sorbent for pre-concentration of sameridine made by molecular imprinting [J].
Andersson, LI ;
Paprica, A ;
Arvidsson, T .
CHROMATOGRAPHIA, 1997, 46 (1-2) :57-62
[6]   Efficient sample pre-concentration of bupivacaine from human plasma by solid-phase extraction on molecularly imprinted polymers [J].
Andersson, LI .
ANALYST, 2000, 125 (09) :1515-1517
[7]   Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography with UV detection [J].
Blomgren, A ;
Berggren, C ;
Holmberg, A ;
Larsson, F ;
Sellergren, B ;
Ensing, K .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) :157-164
[8]   AN INVESTIGATION OF THE EFFECTS OF CARBON LOADING AND ENDCAPPING ON THE SOLID-PHASE EXTRACTION OF BETA-BLOCKERS ONTO C18 BONDED SILICA-GEL [J].
MARTIN, P ;
TABERNER, J ;
FAIRBROTHER, A ;
WILSON, ID .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (08) :671-677
[9]   IMMOBILIZED PHENYLBORONIC ACIDS FOR THE SELECTIVE EXTRACTION OF BETA-BLOCKING DRUGS FROM AQUEOUS-SOLUTION AND PLASMA [J].
MARTIN, P ;
LEADBETTER, B ;
WILSON, ID .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (4-5) :307-312
[10]   Optimisation of procedures for the extraction of structural analogues of propranolol with molecular imprinted polymers for sample preparation [J].
Martin, P ;
Wilson, ID ;
Jones, GR .
JOURNAL OF CHROMATOGRAPHY A, 2000, 889 (1-2) :143-147