Reliability of Ankle-Foot Complex Isokinetic Strength Assessment Using the Isomed 2000 Dynamometer

被引:26
|
作者
Gonosova, Zuzana [1 ]
Linduska, Petr [1 ]
Bizovska, Lucia [1 ]
Svoboda, Zdenek [1 ]
机构
[1] Palacky Univ, Fac Phys Culture, Dept Nat Sci Kinanthropol, Olomouc 77111, Czech Republic
来源
MEDICINA-LITHUANIA | 2018年 / 54卷 / 03期
关键词
plantar flexors; dorsal flexors; ankle invertors; ankle evertors; reproducibility; PLANTAR FLEXION; PEAK-TORQUE; INVERSION; BALANCE; REPRODUCIBILITY; PROPRIOCEPTION; JOINT; POWER; WORK; KNEE;
D O I
10.3390/medicina54030043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For quantifying muscle strength in clinical and research practice, establishing the reliability of measurements, specifically to the procedures used, is essential for credible findings. The objective was to establish the reliability of isokinetic measurement of ankle plantar and dorsal flexors (PF/DF) and invertors and evertors (INV/EV) on an IsoMed 2000 dynamometer. Twenty healthy subjects (10 males, 10 females, mean age: 23.1 +/- 3.1 years) completed an isokinetic measurement session. The intraclass correlation coefficient (ICC) and standard error of measurement were assessed for peak torque and work of ankle PF/DF (concentric and eccentric) and INV/EV (concentric) for the preferred and nonpreferred limb. Standardized isokinetic measurements of reciprocal PF/DF and INV/EV muscle actions were associated with ICC ranging from 0.77 to 0.98 for the majority of observed parameters. The exception was work in the eccentric mode in the ankle DF and peak torque in the concentric mode in the ankle INV on the preferred limb, where ICC ranged from 0.64 to 0.71. The IsoMed 2000 isokinetic dynamometer can be reliably employed in future studies for reciprocal ankle PF/DF and INV/EV assessment in healthy adult subjects after implementation of a familiarization session.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer
    Roth, Ralf
    Donath, Lars
    Kurz, Eduard
    Zahner, Lukas
    Faude, Oliver
    PHYSICAL THERAPY IN SPORT, 2017, 24 : 26 - 31
  • [2] Reliability of isokinetic dynamometer for isometric assessment of ankle plantar flexor strength
    Santy, Fanny-May
    Pernoud, Anthony
    Barrue-Belou, Simon
    Fourchet, Francois
    Bothorel, Hugo
    Samozino, Pierre
    PHYSICAL THERAPY IN SPORT, 2025, 71 : 36 - 42
  • [3] Concentric and eccentric isokinetic knee extension: A reproducibility study using the IsoMed 2000-dynamometer
    Dirnberger, Johannes
    Koesters, Alexander
    Mueller, Erich
    ISOKINETICS AND EXERCISE SCIENCE, 2012, 20 (01) : 31 - 35
  • [4] Reproducibility for isometric and isokinetic maximum knee flexion and extension measurements using the IsoMed 2000-dynamometer
    Dirnberger, Johannes
    Wiesinger, Hans-Peter
    Koesters, Alexander
    Mueller, Erich
    ISOKINETICS AND EXERCISE SCIENCE, 2012, 20 (03) : 149 - 153
  • [5] Reliability of shoulder rotators isokinetic strength imbalance measured using the Biodex dynamometer
    Edouard, Pascal
    Codine, Philippe
    Samozino, Pierre
    Bernard, Pierre-Louis
    Herisson, Christian
    Gremeaux, Vincent
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2013, 16 (02) : 162 - 165
  • [6] Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer
    Impellizzeri, Franco M.
    Bizzini, Mario
    Rampinini, Ermanno
    Cereda, Ferdinando
    Maffiuletti, Nicola A.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2008, 28 (02) : 113 - 119
  • [7] Reliability of isometric and isokinetic trunk flexor strength using a functional electromechanical dynamometer
    Rodriguez-Perea, Angela
    Chirosa Rios, Luis J.
    Martinez-Garcia, Dario
    Ulloa-Diaz, David
    Rojas, Francisco Guede
    Jerez-Mayorga, Daniel
    Chirosa Rios, Ignacio J.
    PEERJ, 2019, 7
  • [8] Reliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: effects of velocity
    Martinez-Garcia, Dario
    Rodriguez-Perea, Angela
    Barboza, Paola
    Ulloa-Diaz, David
    Jerez-Mayorga, Daniel
    Chirosa, Ignacio
    Chirosa Rios, Luis Javier
    PEERJ, 2020, 8
  • [9] RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER
    Alfuth, Martin
    Murielle, Magali
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2016, 11 (01): : 72 - 84
  • [10] Reliability of Ankle Isometric, Isotonic, and Isokinetic Strength and Power Testing in Older Women
    Webber, Sandra C.
    Porter, Michelle M.
    PHYSICAL THERAPY, 2010, 90 (08): : 1165 - 1175