Thermodynamic analysis of a regenerative gas turbine cogeneration plant

被引:0
|
作者
Kumar, Ashok [1 ]
Kachhwaha, S. S. [1 ]
Mishra, R. S. [1 ]
机构
[1] Delhi Coll Engn, Dept Mech Engn, Delhi 110042, India
来源
JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH | 2010年 / 69卷 / 03期
关键词
Gas turbine cogeneration plant; Parametric study; Thermodynamic analysis; 2ND-LAW ANALYSIS; SYSTEM;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Design methodology has been developed for parametric study and thermodynamic performance evaluation of a gas turbine cogeneration system (GTCS). Parametric study showed that compression ratio (r(p)), inlet air temperature, turbine inlet temperature, steam pressure and pinch point temperature played a very vital role on overall performance of GTCS. Exergy analysis revealed that most sensitive components in GTCS were combustion chamber and regenerator.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条