摘要
In the frame of the French national research program PRIMEQUAL (inter-ministry program for better air quality in urban environments), measurements of outdoor and indoor pollution have been carried out in eight schools in La Rochelle (France) and its suburbs. The buildings were naturally ventilated by opening the windows, or mechanically ventilated, and showed various air permeabilities. Ozone, nitrogen oxides (NO and NO2), and airborne particle (particle counts within 15 size intervals ranging from 0.3 to 15 mum) concentrations were continuously monitored indoors and outdoors for two 2-week periods. The indoor humidity, temperature, CO2 concentration (an indicator of occupancy), window openings and building permeability were also measured. The temporal profiles of indoor and outdoor concentrations show ozone and nitrogen oxides behave differently: NO and NO2 indoor/outdoor concentration ratios (I/O) were found to vary in a range from 0.5 to 1, and from 0.88 to 1, respectively, but no correlation with building permeability was observed. On the contrary, I/O ratios of ozone vary in a range from 0 to 0.45 and seem to be strongly influenced by the building air-tightness: the more airtight the building envelope, the lower the ratio. Occupancy, through re-suspension of previously deposited particles and possible particle generation, strongly influences the indoor concentration level of airborne particles. However, this influence decreases with particle size, reflecting the way deposition velocities vary as a function of size. The influence of particle size on deposition and penetration across the building envelope is also discussed by analyzing the I/O ratios measured when the buildings were unoccupied, by comparing the indoor concentrations measured when the buildings were occupied and when they were not (O/U ratios), and by referring to previously published studies focussing on this topic. Except one case, I/O were found to vary in the range from 0.03 to 1.79. All O/U are greater than one and increase up to 100 with particle size.
引用
收藏
页码:2 / 12
页数:11
相关论文
共 50 条
  • [41] Investigation of air pollution mitigation measures, ventilation, and indoor air quality at three schools in London
    Abhijith, K. V.
    Kukadia, Vina
    Kumar, Prashant
    ATMOSPHERIC ENVIRONMENT, 2022, 289
  • [42] Assessment of indoor and outdoor air quality in primary schools of Cyprus during the COVID-19 pandemic measures in May-July 2021
    Konstantinou, Corina
    Constantinou, Andria
    Kleovoulou, Eleni G.
    Kyriacou, Alexis
    Kakoulli, Christina
    Milis, George
    Michaelides, Michalis
    Makris, Konstantinos C.
    HELIYON, 2022, 8 (05)
  • [43] Indoor air quality in an air-conditioned building in new Delhi and its relationship to ambient air quality
    Prasad, RK
    Uma, R
    Kansal, A
    Gupta, S
    Kumar, P
    Saksena, S
    INDOOR AND BUILT ENVIRONMENT, 2002, 11 (06) : 334 - 339
  • [44] Relationships between ventilation and indoor air quality: A review
    Godish, T
    Spengler, JD
    INDOOR AIR, 1996, 6 (02) : 135 - 145
  • [45] Health effects of outdoor and indoor air pollution
    Pene, Pierre
    Masse, Roland
    BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2009, 193 (06): : 1387 - 1415
  • [46] Indoor Air Quality in Brazilian Universities
    Jurado, Sonia R.
    Bankoff, Antonia D. P.
    Sanchez, Andrea
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2014, 11 (07): : 7081 - 7093
  • [47] Relationship among environmental quality variables, housing variables, and residential needs: a secondary analysis of the relationship among indoor, outdoor, and personal air (RIOPA) concentrations database
    Fausto Garcia
    Derek G. Shendell
    Jaime Madrigano
    International Journal of Biometeorology, 2017, 61 : 513 - 525
  • [48] Relationship among environmental quality variables, housing variables, and residential needs: a secondary analysis of the relationship among indoor, outdoor, and personal air (RIOPA) concentrations database
    Garcia, Fausto, Jr.
    Shendell, Derek G.
    Madrigano, Jaime
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2017, 61 (03) : 513 - 525
  • [49] Can changing the timing of outdoor air intake reduce indoor concentrations of traffic-related pollutants in schools?
    MacNeill, M.
    Dobbin, N.
    St-Jean, M.
    Wallace, L.
    Marro, L.
    Shin, T.
    You, H.
    Kulka, R.
    Allen, R. W.
    Wheeler, A. J.
    INDOOR AIR, 2016, 26 (05) : 687 - 701
  • [50] Indoor-outdoor air quality relationships in vehicle: effect of driving environment and ventilation modes
    Chan, AT
    Chung, MW
    ATMOSPHERIC ENVIRONMENT, 2003, 37 (27) : 3795 - 3808