Relationship between outdoor and indoor air quality in eight French schools

被引:254
|
作者
Blondeau, P [1 ]
Iordache, V [1 ]
Poupard, O [1 ]
Genin, D [1 ]
Allard, F [1 ]
机构
[1] Univ La Rochelle, LEPTAB, F-17042 La Rochelle 1, France
关键词
I/O ratios; ozone; nitrogen oxides; particle size distribution; school; building air-tightness; ventilation;
D O I
10.1111/j.1600-0668.2004.00263.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the frame of the French national research program PRIMEQUAL (inter-ministry program for better air quality in urban environments), measurements of outdoor and indoor pollution have been carried out in eight schools in La Rochelle (France) and its suburbs. The buildings were naturally ventilated by opening the windows, or mechanically ventilated, and showed various air permeabilities. Ozone, nitrogen oxides (NO and NO2), and airborne particle (particle counts within 15 size intervals ranging from 0.3 to 15 mum) concentrations were continuously monitored indoors and outdoors for two 2-week periods. The indoor humidity, temperature, CO2 concentration (an indicator of occupancy), window openings and building permeability were also measured. The temporal profiles of indoor and outdoor concentrations show ozone and nitrogen oxides behave differently: NO and NO2 indoor/outdoor concentration ratios (I/O) were found to vary in a range from 0.5 to 1, and from 0.88 to 1, respectively, but no correlation with building permeability was observed. On the contrary, I/O ratios of ozone vary in a range from 0 to 0.45 and seem to be strongly influenced by the building air-tightness: the more airtight the building envelope, the lower the ratio. Occupancy, through re-suspension of previously deposited particles and possible particle generation, strongly influences the indoor concentration level of airborne particles. However, this influence decreases with particle size, reflecting the way deposition velocities vary as a function of size. The influence of particle size on deposition and penetration across the building envelope is also discussed by analyzing the I/O ratios measured when the buildings were unoccupied, by comparing the indoor concentrations measured when the buildings were occupied and when they were not (O/U ratios), and by referring to previously published studies focussing on this topic. Except one case, I/O were found to vary in the range from 0.03 to 1.79. All O/U are greater than one and increase up to 100 with particle size.
引用
收藏
页码:2 / 12
页数:11
相关论文
共 50 条
  • [21] Assessment of Indoor Air Quality in Schools from Anatolia, Turkey
    Babaoglu, Ulken Tunga
    Ogutcu, Hatice
    Erdogdu, Makbule
    Taskiran, Funda
    Gullu, Gulen
    Oymak, Sibel
    POLLUTION, 2022, 8 (01): : 57 - 67
  • [22] Measurement of indoor air quality for ventilation with the existence of occupants in schools
    Shin, HS
    Lee, JK
    Ahn, YC
    Yeo, CS
    Byun, SH
    Lee, JK
    Kang, TW
    Lee, KG
    Park, HS
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2005, 19 (04) : 1001 - 1005
  • [23] Measurement of indoor air quality for ventilation with the existence of occupants in schools
    Shin, HS
    Ahn, YC
    Lee, JK
    Kang, TW
    Lee, KG
    Park, HS
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2762 - 2766
  • [24] Measurement of indoor air quality for ventilation with the existence of occupants in schools
    Hee-Soo Shin
    Jai-Kwon Lee
    Young-Chull Ahn
    Chang-Shin Yeo
    Sang-Hyun Byun
    Jae-Keun Lee
    Tae-Wook Kang
    Kam-Gyu Lee
    Hyo-Soon Park
    Journal of Mechanical Science and Technology, 2005, 19 : 1001 - 1005
  • [25] Indoor air quality in Portuguese schools: levels and sources of pollutants
    Madureira, J.
    Paciencia, I.
    Pereira, C.
    Teixeira, J. P.
    Fernandes, E. de O.
    INDOOR AIR, 2016, 26 (04) : 526 - 537
  • [26] Indoor air quality in kindergartens: the relationship between environmental parameters and levels of occupation of spaces
    Santos, Joana
    Aguiar, Mafalda
    Carvalhais, Carlos
    Pereira, Cristiana
    Fernandes, Anabela
    Silva, Manuela
    Baptista, Joao
    Teixeira, Joao
    SHO2011: INTERNATIONAL SYMPOSIUM ON OCCUPATIONAL SAFETY AND HYGIENE, 2011, : 582 - 587
  • [27] Relationship of indoor and outdoor air pollutants in a naturally ventilated historical building envelope
    Lopez-Aparicio, S.
    Smolik, J.
    Maskova, L.
    Souckova, M.
    Grontoft, T.
    Ondrackova, L.
    Stankiewicz, J.
    BUILDING AND ENVIRONMENT, 2011, 46 (07) : 1460 - 1468
  • [28] RELATIONSHIPS BETWEEN INDOOR AND OUTDOOR AIR-QUALITY IN 4 NATURALLY VENTILATED OFFICES IN THE UNITED-KINGDOM
    PHILLIPS, JL
    FIELD, R
    GOLDSTONE, M
    REYNOLDS, GL
    LESTER, JN
    PERRY, R
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1993, 27 (11): : 1743 - 1753
  • [29] The relationship between indoor air quality (IAQ) and perceived air quality (PAQ) – a review and case analysis of Chinese residential environment
    Pei J.
    Qu M.
    Sun L.
    Wang X.
    Yin Y.
    Energy and Built Environment, 2024, 5 (02): : 230 - 243
  • [30] Evaluation of indoor and outdoor air quality of a nursery school in Mexico City.
    Cortez-Lugo, M
    Mercado-Garcia, A
    Hernandez-Avila, M
    Meneses-Gonzalez, F
    Palazuelos-Rendon, E
    SALUD PUBLICA DE MEXICO, 1998, 40 (05): : 415 - 420