Relationship between outdoor and indoor air quality in eight French schools

被引:254
|
作者
Blondeau, P [1 ]
Iordache, V [1 ]
Poupard, O [1 ]
Genin, D [1 ]
Allard, F [1 ]
机构
[1] Univ La Rochelle, LEPTAB, F-17042 La Rochelle 1, France
关键词
I/O ratios; ozone; nitrogen oxides; particle size distribution; school; building air-tightness; ventilation;
D O I
10.1111/j.1600-0668.2004.00263.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the frame of the French national research program PRIMEQUAL (inter-ministry program for better air quality in urban environments), measurements of outdoor and indoor pollution have been carried out in eight schools in La Rochelle (France) and its suburbs. The buildings were naturally ventilated by opening the windows, or mechanically ventilated, and showed various air permeabilities. Ozone, nitrogen oxides (NO and NO2), and airborne particle (particle counts within 15 size intervals ranging from 0.3 to 15 mum) concentrations were continuously monitored indoors and outdoors for two 2-week periods. The indoor humidity, temperature, CO2 concentration (an indicator of occupancy), window openings and building permeability were also measured. The temporal profiles of indoor and outdoor concentrations show ozone and nitrogen oxides behave differently: NO and NO2 indoor/outdoor concentration ratios (I/O) were found to vary in a range from 0.5 to 1, and from 0.88 to 1, respectively, but no correlation with building permeability was observed. On the contrary, I/O ratios of ozone vary in a range from 0 to 0.45 and seem to be strongly influenced by the building air-tightness: the more airtight the building envelope, the lower the ratio. Occupancy, through re-suspension of previously deposited particles and possible particle generation, strongly influences the indoor concentration level of airborne particles. However, this influence decreases with particle size, reflecting the way deposition velocities vary as a function of size. The influence of particle size on deposition and penetration across the building envelope is also discussed by analyzing the I/O ratios measured when the buildings were unoccupied, by comparing the indoor concentrations measured when the buildings were occupied and when they were not (O/U ratios), and by referring to previously published studies focussing on this topic. Except one case, I/O were found to vary in the range from 0.03 to 1.79. All O/U are greater than one and increase up to 100 with particle size.
引用
收藏
页码:2 / 12
页数:11
相关论文
共 50 条
  • [11] Investigation of indoor air quality at urban schools in Qatar
    Abdel-Salam, Mahmoud M. M.
    INDOOR AND BUILT ENVIRONMENT, 2019, 28 (02) : 278 - 288
  • [12] Indoor air quality in elementary schools of Lisbon in spring
    Pegas, P. N.
    Alves, C. A.
    Evtyugina, M. G.
    Nunes, T.
    Cerqueira, M.
    Franchi, M.
    Pio, C. A.
    Almeida, S. M.
    Freitas, M. C.
    ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 2011, 33 (05) : 455 - 468
  • [13] Investigation of indoor and outdoor air quality of the classrooms at a school in Serbia
    Jovanovic, Marina
    Vucicevic, Biljana
    Turanjanin, Valentina
    Zivkovic, Marija
    Spasojevic, Vuk
    ENERGY, 2014, 77 : 42 - 48
  • [14] Indoor air quality in primary schools in Kecioren, Ankara
    Babayigit, Mustafa Alparslan
    Bakir, Bilal
    Tekbas, Omer Faruk
    Ogur, Recai
    Kilic, Abdullah
    Ulus, Serdar
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2014, 44 (01) : 137 - 144
  • [15] A Comparison Study of Indoor and Outdoor Air Quality in Nanjing, China
    Xu, Ruochong
    Qi, Ximeng
    Dai, Guoqing
    Lin, Haoxian
    Zhai, Peng
    Zhu, Caijun
    Wang, Lei
    Ding, Aijun
    AEROSOL AND AIR QUALITY RESEARCH, 2020, 20 (10) : 2128 - 2141
  • [16] Asthmatic symptoms among pupils in relation to winter indoor and outdoor air pollution in schools in Taiyuan, China
    Zhao, Zhuohui
    Zhang, Zheng
    Wang, Zhuanhua
    Ferm, Martin
    Liang, Yanling
    Norback, Dan
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2008, 116 (01) : 90 - 97
  • [17] Evaluation of indoor and outdoor air quality in university academic buildings and associated health risk
    Mundackal, Antony
    Ngole-Jeme, Veronica M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH, 2022, 32 (05) : 1076 - 1094
  • [18] Indoor air measurement campaign in Helsinki, Finland 1999 - the effect of outdoor air pollution on indoor air
    Koponen, IK
    Asmi, A
    Keronen, P
    Puhto, K
    Kulmala, M
    ATMOSPHERIC ENVIRONMENT, 2001, 35 (08) : 1465 - 1477
  • [19] The relationship between indoor and outdoor airborne particles in the residential environment
    Morawska, L
    He, CR
    Hitchins, J
    Gilbert, D
    Parappukkaran, S
    ATMOSPHERIC ENVIRONMENT, 2001, 35 (20) : 3463 - 3473
  • [20] The effect of natural ventilation strategy on indoor air quality in schools
    Stabile, Luca
    Dell'Isola, Marco
    Russi, Aldo
    Massimo, Angelamaria
    Buonanno, Giorgio