共 37 条
Diclofenac in municipal wastewater treatment plant: quantification using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry approach in comparison with an established liquid chromatography-electrospray ionization-tandem mass spectrometry method
被引:48
作者:
Lonappan, Linson
[1
]
Pulicharla, Rama
[1
]
Rouissi, Tarek
[1
]
Brar, Satinder K.
[1
]
Verma, Mausam
[2
]
Surampalli, Rao Y.
[3
]
Valero, Jose R.
[1
]
机构:
[1] Univ Quebec, INRS ETE, 490 Rue Couronne, Quebec City, PQ G1K 9A9, Canada
[2] CO2 Solut Inc, Rue Jean Perrin, Quebec City, PQ G2C 1T9, Canada
[3] Univ Nebraska, Dept Civil Engn, N104 SEC POB 886105, Lincoln, NE 68588 USA
基金:
加拿大自然科学与工程研究理事会;
关键词:
Diclofenac-emerging contaminant;
Wastewater;
Wastewater sludge;
LC-ESI-MS/MS;
LDTD-APCI-MS/MS;
Quantification;
PHARMACEUTICAL COMPOUNDS;
SEWAGE-SLUDGE;
AQUATIC ENVIRONMENT;
EXTRACTION;
REMOVAL;
FATE;
SEDIMENTS;
TOXICITY;
RESIDUES;
DRUGS;
D O I:
10.1016/j.chroma.2016.01.030
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Diclofenac (DCF), a prevalent non-steroidal anti-inflammatory drug (NSAID) is often detected in wastewater and surface water. Analysis of the pharmaceuticals in complex matrices is often laden with challenges. In this study a reliable, rapid and sensitive method based on laser diode thermal desorption/atmospheric pressure chemical ionization (LDTD/APCI) coupled with tandem mass spectrometry (MS/MS) has been developed for the quantification of DCF in wastewater and wastewater sludge. An established conventional LC-ESI-MS/MS (liquid chromatography-electrospray ionization-tandem mass spectrometry) method was compared with LDTD-APCI-MS/MS approach. The newly developed LDTD-APCI-MS/MS method reduced the analysis time to 12 sin lieu of 12 min for LC-ESI-MS/MS method. The method detection limits for LDTD-APCI-MS/MS method were found to be 270 ng L-1 (LOD) and 1000 ng L-1 (LOQ). Furthermore, two extraction procedures, ultrasonic assisted extraction (USE) and accelerated solvent extraction (ASE) for the extraction of DCF from wastewater sludge were compared and ASE with 95.6 +/- L 7% recovery was effective over USE with 86 +/- 4% recovery. The fate and partitioning of DCF in wastewater (WW) and wastewater sludge (WWS) in wastewater treatment plant was also monitored at various stages of treatment in Quebec Urban community wastewater treatment plant. DCF exhibited affinity towards WW than WWS with a presence about 60% of DCF in WW in contrary with theoretical prediction (Log K-ow = 4.51). (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:106 / 113
页数:8
相关论文