Air-void structure, strength, and permeability of wet-mix shotcrete before and after shotcreting Operation: The influences of silica fume and air-entraining agent

被引:108
作者
Choi, Pangil [1 ]
Yeon, Jung Heum [2 ]
Yun, Kyong-Ku [3 ]
机构
[1] Texas Tech Univ, Dept Civil & Environm Engn, Lubbock, TX 79409 USA
[2] Gachon Univ, Dept Civil & Environm Engn, Songnam, South Korea
[3] Kangwon Natl Univ, Dept Civil Engn, Chunchon, South Korea
关键词
Wet-mix shotcrete; Air-void structure; Strength; Permeability; Silica fume; Air-entraining agent; HARDENED CEMENT PASTE; RELATIVE-HUMIDITY; CONCRETE;
D O I
10.1016/j.cemconcomp.2016.03.012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is well known that the air-void structure of hardened concrete has substantial effects on the mechanical properties and durability of concrete. In this study, laboratory evaluations were conducted to quantify the effects of air-entraining agent (AEA) and silica fume on the air-void characteristics of wet mix shotcrete (WMS) before and after shotcreting process. For this purpose, a high-resolution image analyzer capturing elaborate graphical layouts of air-void structure using the linear transverse method was employed. Also, this study examined the effects of air-void characteristics, such as air content and spacing factor, on the strength and permeability of WMS. Based on the findings of this study, it can be concluded that: (1) shotcreting process considerably reduces overall air contents in WMS; (2) incorporating AEA with a 4.5% silica fume replacement ensures both satisfactory spacing factor and good retention of small entrained air bubbles even after shotcreting, which may improve the freeze-thaw and scaling resistance; (3) the compressive and flexural strengths of WMS were reduced as the air content increased and average spacing factor decreased; and (4) the air content affected the permeability of WMS, but no consistent correlation was found between spacing factor and permeability. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 17 条
[1]  
[Anonymous], TRANSP RES REC
[2]  
Boulet D., 1997, THESIS LAVAL U QUEBE
[3]  
Choi S.Y., 2008, THESIS KANGWON NATL
[4]  
DENARIE E, 1995, AMER CONC I, V153, P763
[5]   Mechanisms of air entrainment in concrete [J].
Du, LX ;
Folliard, KJ .
CEMENT AND CONCRETE RESEARCH, 2005, 35 (08) :1463-1471
[6]   Thermal dilation and internal relative humidity of hardened cement paste [J].
Grasley, Zachary C. ;
Lange, David A. .
MATERIALS AND STRUCTURES, 2007, 40 (03) :311-317
[7]  
Hover K., 1989, CEMENT CONCRETE AGGR, P67, DOI [10.1520/CCA10104J, DOI 10.1520/CCA10104J]
[8]  
Hover K., 1993, Concr. Constr, V38, P11
[9]  
Kosmatka S.H., 1994, DESIGN CONTROL CONCR
[10]  
Mehta P.K., 2017, CONCRETE MICROSTRUCT