Research on formation mechanism of typical low-temperature fouling layers in biomass-fired boilers

被引:7
|
作者
Ma, Lei [1 ,3 ]
Wei, Wei [2 ]
Sun, Fengzhong [1 ]
Shi, Yuetao [1 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Shandong, Peoples R China
[2] Qilu Univ Technol, Sch Energy & Power Engn, Shandong Acad Sci, Jinan 250353, Shandong, Peoples R China
[3] Jinan Inst Measurement & Testing, Jinan 250000, Shandong, Peoples R China
关键词
Biomass-fired boilers; Typical ash layer; NH4Cl crystallization; Condensation; Deliquescent chlorides; Critical deliquescence temperature; DEW-POINT CORROSION; HEAT-EXCHANGERS; AQUEOUS-SOLUTIONS; VAPOR-PRESSURE; ACID; COAL; PREDICTION; DEPOSITION; PYROLYSIS; SURFACE;
D O I
10.1016/j.csite.2022.102076
中图分类号
O414.1 [热力学];
学科分类号
摘要
Ash deposition in flue gas covering low-temperature surfaces (<150 degrees C) of biomass-fired power plants have two typical characteristics that are distinct from that of coal-fired power plant. First, NH4Cl is present in the deposited ash when the surface temperature is adequately low. Second, hygroscopic salts, such as CaCl2, MgCl2, NaCl etc. are present in the deposited ash, which may cause the ash to adhere to the surface when the salts absorb water. In this study, a test system with transformable cooling media was designed according to the measured temperature needs for on-site ash deposition experiments in a 35 MW biomass-fired power plant. Scanning electron microscope (SEM) equipped with energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD) were used to analyze the ash samples collected during the experiment. The results show that four typical ash deposition layers were obtained by varying the tested pipe temperature during the cooling process, i.e., dry-loose ash layer (>120 degrees C), multi-loose ash layer (120-90 degrees C), adhering ash layer (90-60 degrees C), and viscous ash layer (<60 degrees C). In order to study the formation mechanism of typical low-temperature fouling layers, the following analyses were performed: the boundary temperature of NH4Cl crystallization was calculated, the condensations of H2SO4 and HCl were analyzed, critical deliquescence temperatures (CDTs) of deliquescent chlorides were calculated, and water uptake of deliquescent chlorides under different temperatures and moisture were proposed.
引用
收藏
页数:16
相关论文
共 50 条