Transapical Aortic Valve Implantation: Predictors of Leakage and Impact On Survival: An Update

被引:4
作者
Unbehaun, Axel [1 ]
Pasic, Miralem [1 ]
Kukucka, Marian [1 ]
Mladenow, Alexander [1 ]
Solowjowa, Natalia [1 ]
Dreysse, Stephan [1 ]
Drews, Thorsten [1 ]
Penkalla, Adam [1 ]
Hetzer, Roland [1 ]
Buz, Semih [1 ]
机构
[1] Deutsch Herzzentrum Berlin, D-13353 Berlin, Germany
关键词
DEVICE LANDING ZONE; TRANSCATHETER; REPLACEMENT; REGURGITATION; OUTCOMES; SERIES;
D O I
10.1016/j.athoracsur.2014.05.084
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. In line with our institutional strategy, we do not accept paravalvular leakage after transcatheter aortic valve implantation (TAVI). Apart from data from very limited initial experience, predictors of leakage in large cohorts treated with new types of TAVI prostheses are still lacking. Methods. From April 2008 to August 2013, 730 patients underwent transapical TAVI at our institution. The study group consisted of all 324 patients who received the new generation of balloon-expandable prostheses (SAPIENXT; Edwards Lifesciences, LLC, Irvine, CA). Based on the Society of Thoracic Surgeons predicted risk of mortality, the arithmetic risk for surgery in the study cohortwas 11% +/- 9% (1% to 62%) and 20 (6%) patients were in cardiogenic shock. Results. In study cohort, the overall 30-day mortality rate was 4.0% (3.3% in patients without cardiogenic shock). The postprocedural grade of regurgitation was absent or trace in 269 of 324 patients (83%), mild in 52 of 324 (16%), and moderate in 3 of 324 (< 1%); there was no severe postprocedural regurgitation. Regurgitation occurred less often (p < 0.001) in patients who received the XT-type prosthesis. Patients with more than trace regurgitation presented with less oversizing of the prosthesis in terms of annular area (p < 0.001) and higher calcium scores of the device landing zone (p < 0.001). The presence of calcified plaques in the left ventricular outflow tract was the strongest predictor of leakage (odds ratio 10.23, 95% confidence interval 5.12 to 20.45, p < 0.001). The regurgitation grade was not predictive for follow-up mortality (hazard ratio 1.08, 95% confidence interval 0.61 to 1.90, p = 0.800). Conclusions. In transapical TAVI, the risk of relevant paravalvular leakage may be eliminated completely. There is no negative impact on survival in patients with lesser, irrelevant grades of regurgitation. (C) 2014 by The Society of Thoracic Surgeons
引用
收藏
页码:1308 / 1315
页数:8
相关论文
共 21 条
[1]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[2]   Paravalvular Leak After Transcatheter Aortic Valve Replacement The New Achilles' Heel? A Comprehensive Review of the Literature [J].
Genereux, Philippe ;
Head, Stuart J. ;
Hahn, Rebecca ;
Daneault, Benoit ;
Kodali, Susheel ;
Williams, Mathew R. ;
van Mieghem, Nicolas M. ;
Alu, Maria C. ;
Serruys, Patrick W. ;
Kappetein, A. Pieter ;
Leon, Martin B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (11) :1125-1136
[3]   The German Aortic Valve Registry (GARY): in-hospital outcome [J].
Hamm, Christian W. ;
Moellmann, Helge ;
Holzhey, David ;
Beckmann, Andreas ;
Veit, Christof ;
Figulla, Hans-Reiner ;
Cremer, J. ;
Kuck, Karl-Heinz ;
Lange, Ruediger ;
Zahn, Ralf ;
Sack, Stefan ;
Schuler, Gerhard ;
Walther, Thomas ;
Beyersdorf, Friedhelm ;
Boehm, Michael ;
Heusch, Gerd ;
Funkat, Anne-Kathrin ;
Meinertz, Thomas ;
Neumann, Till ;
Papoutsis, Konstantinos ;
Schneider, Steffen ;
Welz, Armin ;
Mohr, Friedrich W. .
EUROPEAN HEART JOURNAL, 2014, 35 (24) :1588-1598
[4]   Cross-Sectional Computed Tomographic Assessment Improves Accuracy of Aortic Annular Sizing for Transcatheter Aortic Valve Replacement and Reduces the Incidence of Paravalvular Aortic Regurgitation [J].
Jilaihawi, Hasan ;
Kashif, Mohammad ;
Fontana, Gregory ;
Furugen, Azusa ;
Shiota, Takahiro ;
Friede, Gerald ;
Makhija, Rakhee ;
Doctor, Niraj ;
Leon, Martin B. ;
Makkar, Raj R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (14) :1275-1286
[5]   Correlation of Device Landing Zone Calcification and Acute Procedural Success in Patients Undergoing Transcatheter Aortic Valve Implantations With the Self-Expanding CoreValve Prosthesis [J].
John, Daniel ;
Buellesfeld, Lutz ;
Yuecel, Seyrani ;
Mueller, Ralf ;
Latsios, Georg ;
Beucher, Harald ;
Gerckens, Ulrich ;
Grube, Eberhard .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (02) :233-243
[6]  
Kappetein AP, 2012, J AM COLL CARDIOL, V60, P1438, DOI [10.1016/j.jacc.2012.09.001, 10.1093/ejcts/ezs533]
[7]   Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement [J].
Kodali, Susheel K. ;
Williams, Mathew R. ;
Smith, Craig R. ;
Svensson, Lars G. ;
Webb, John G. ;
Makkar, Raj R. ;
Fontana, Gregory P. ;
Dewey, Todd M. ;
Thourani, Vinod H. ;
Pichard, Augusto D. ;
Fischbein, Michael ;
Szeto, Wilson Y. ;
Lim, Scott ;
Greason, Kevin L. ;
Teirstein, Paul S. ;
Malaisrie, S. Chris ;
Douglas, Pamela S. ;
Hahn, Rebecca T. ;
Whisenant, Brian ;
Zajarias, Alan ;
Wang, Duolao ;
Akin, Jodi J. ;
Anderson, William N. ;
Leon, Martin B. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (18) :1686-1695
[8]   Paravalvular Aortic Leak After Transcatheter Aortic Valve Replacement Current Knowledge [J].
Lerakis, Stamatios ;
Hayek, Salim S. ;
Douglas, Pamela S. .
CIRCULATION, 2013, 127 (03) :397-407
[9]   Outcomes Following Transcatheter Aortic Valve Replacement in the United States [J].
Mack, Michael J. ;
Brennan, J. Matthew ;
Brindis, Ralph ;
Carroll, John ;
Edwards, Fred ;
Grover, Fred ;
Shahian, David ;
Tuzcu, E. Murat ;
Peterson, Eric D. ;
Rumsfeld, John S. ;
Hewitt, Kathleen ;
Shewan, Cynthia ;
Michaels, Joan ;
Christensen, Barb ;
Christian, Alexander ;
O'Brien, Sean ;
Holmes, David .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2013, 310 (19) :2069-2077
[10]   Outcome of mild periprosthetic regurgitation detected by intraoperative transesophageal echocardiography [J].
O'Rourke, DJ ;
Palac, RT ;
Malenka, DJ ;
Marrin, CAS ;
Arbuckle, BE ;
Plehn, JF .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (01) :163-166