Piezoelectric vs. conventional drilling in implant site preparation: pilot controlled randomized clinical trial with crossover design

被引:46
作者
Canullo, Luigi
Penarrocha, David [1 ]
Penarrocha, Miguel [1 ]
Rocio, Alonso-Gonzalez [1 ]
Penarrocha-Diago, Maria [2 ]
机构
[1] Valencia Univ Med & Dent Sch, Valencia, Spain
[2] Valencia Univ Med & Dent Sch, Dept Stomatol, Valencia, Spain
关键词
implant stability; piezosurgery; randomized clinical trial; ultrasounds; RESONANCE FREQUENCY-ANALYSIS; BONE SURGERY; STABILITY; OSSEOINTEGRATION; PIEZOSURGERY; PLACEMENT; INTERFACE; SURFACE;
D O I
10.1111/clr.12278
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare implant stability throughout osseointegration, peri-implant marginal bone loss, and success rates of implants placed with conventional and mixed drilling/piezoelectric osteotomy. Materials and methods: A pilot randomized-controlled trial was performed on 15 patients. Each patient received two implants in the mandibular molar region. All sites were prepared with conventionally up to the 2.8 mm wide drill. Osteotomies were randomly finalized with a 3 mm diameter drill (control group) or with two consecutive ultrasonic tips (2.8 mm and 3 mm wide, respectively) (test group). Resonance frequency analysis measurements were taken at implant placement and after 1, 3, 8, and 12 weeks. Peri-implant marginal bone loss 12 months after loading was calculated using periapical radiographs. Wilcoxon test for related samples was used to study differences in implant stability and in peri-implant marginal bone loss between the two groups. Results: Twenty-nine of 30 implants osseointegrated successfully (one failure in the control group). Stability was significantly higher in the test group at the 8th week assessment; differences were non-significant at all other time-points. Longitudinally, differences were observed between the patterns of implant stability changes: in the test group stability increased more progressively, while in the control group an abrupt change occurred between the 8th and 12th weeks assessments. No difference was found in peri-implant marginal bone loss between the groups. All 29 implants were functionally successful at the 15-month visit. Conclusions: Within the limit of this pilot study (small sample size, short follow-up), data suggested that implant stability might develop slightly faster when implant site osteotomy is performed with a mixed drilling/ultrasonic technique.
引用
收藏
页码:1336 / 1343
页数:8
相关论文
共 31 条
[1]   The mucosal barrier following abutment dis/reconnection - An experimental study in dogs [J].
Abrahamsson, I ;
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1997, 24 (08) :568-572
[2]   Implant stability in relation to osseointegration: an experimental study in the Labrador dog [J].
Abrahamsson, Ingemar ;
Linder, Elena ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (03) :313-318
[3]  
Altman DG, 1996, BRIT MED J, V313, P570
[4]  
Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
[5]  
Barewal RM, 2003, INT J ORAL MAX IMPL, V18, P641
[6]  
Bengazi F., 2012, CLIN ORAL IMPLAN RES, V12, P1
[7]   Split-crest and immediate implant placement with ultra-sonic bone surgery: a 3-year life-table analysis with 230 treated sites [J].
Blus, Cornelio ;
Szmukler-Moncler, Serge .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (06) :700-707
[8]  
Blus C, 2010, INT J PERIODONT REST, V30, P355
[9]  
Branemark P I, 1977, Scand J Plast Reconstr Surg Suppl, V16, P1
[10]  
BRUNSKI J B, 1992, Clinical Materials, V10, P153, DOI 10.1016/0267-6605(92)90049-Y