Open Questions on Unified Approach for Calibration of Oscillometric Blood Pressure Measurement Devices

被引:4
作者
Balestrieri, E. [1 ]
Daponte, P. [1 ]
Rapuano, S. [1 ]
机构
[1] Univ Sannio, Dept Engn, I-82100 Benevento, Italy
来源
MEMEA: 2009 IEEE INTERNATIONAL WORKSHOP ON MEDICAL MEASUREMENTS AND APPLICATIONS | 2009年
关键词
Blood pressure; non-invasive measurement; oscillometric; calibration; standardization; simulators; VALIDATION; SIMULATOR;
D O I
10.1109/MEMEA.2009.5167985
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Most of automatic blood pressure measurement devices on the market implement an oscillometric method. The paper highlights the need for standardized calibration procedures for these devices in order to reduce logistical difficulties, time-consuming processes and high costs involved in clinical validations. A critical overview of researchers' and manufacturers' proposals to answer this need is presented as a contribution to the IEEE P1721 project for a new standard on Objective Measurement of Systemic Arterial Blood Pressure in Humans.
引用
收藏
页码:206 / 211
页数:6
相关论文
共 36 条
[1]   Can a simulator that regenerates physiological waveforms evaluate oscillometric non-invasive blood pressure devices? [J].
Amoore, JN ;
Vacher, E ;
Murray, IC ;
Mieke, S ;
King, ST ;
Smith, FE ;
Murray, A .
BLOOD PRESSURE MONITORING, 2006, 11 (02) :63-67
[2]  
AMOORE JN, 1997, P IFMBE P11, V16, P342
[3]   Validation of oscillometric noninvasive blood pressure measurement devices using simulators [J].
Amoore, John N. ;
Lemesre, Yann ;
Murray, Ian C. ;
Vacher, Emilie ;
Mieke, Stephan ;
King, Susan T. ;
Smith, Fiona E. ;
Murray, Alan .
BLOOD PRESSURE MONITORING, 2007, 12 (04) :251-253
[4]  
*APEC APLMF, 2006, HDB AUTOMATED SPHYGM
[5]   Automated non-invasive measurement of blood pressure: Standardization of calibration procedures [J].
Balestrieri, E. ;
Daponte, P. ;
Rapuano, S. .
2008 IEEE INTERNATIONAL WORKSHOP ON MEDICAL MEASUREMENTS AND APPLICATIONS, 2008, :124-+
[6]   An experience in implementing the oscillometric algorithm for the non-invasive determination of human blood pressure. [J].
Ball-Ilovera, A ;
Del Rey, R ;
Ruso, R ;
Ramos, J ;
Batista, O ;
Niubo, I .
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 :3173-3175
[7]   Development and validation of a noninvasive method to determine arterial pressure and vascular compliance [J].
Brinton, TJ ;
Cotter, B ;
Kailasam, MT ;
Brown, DL ;
Chio, SS ;
OConnor, DT ;
DeMaria, AN .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (03) :323-330
[8]  
Clifford GD, 2004, COMPUT CARDIOL, V31, P709
[9]  
Clifford GD, 2004, P 17 INT EURASIP C B, P358
[10]  
DAIMIWAL N, 2007, J INSTRUMENT SOC IND, V37, P243