Variability of MDCT Dose Due to Technologist Performance: Impact of Posteroanterior Versus Anteroposterior Localizer Image and Table Height With Use of Automated Tube Current Modulation

被引:30
作者
Harri, Peter A. [1 ]
Moreno, Courtney C. [1 ]
Nelson, Rendon C. [2 ]
Fani, Negar [1 ]
Small, William C. [1 ]
Duong, Anh [1 ]
Tang, Xiangyang [1 ]
Applegate, Kimberly E. [1 ]
机构
[1] Emory Univ, Dept Radiol & Imaging Sci, Sch Med, Atlanta, GA 30322 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
automated tube current modulation; CT; radiation dose; RADIATION-EXPOSURE; CT SCANS; QUALITY;
D O I
10.2214/AJR.13.11608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine MDCT dose variability due to technologist variability in performing CT studies. MATERIALS AND METHODS. Fifty consecutive adult patients who underwent two portal venous phase CT examinations of the abdomen and pelvis on the same 64-MDCT scanner between January and December 2011 were retrospectively identified. Tube voltage (kVp), tube current (mA), use of automated tube current modulation (ATCM), dose-length product (DLP), volume CT dose index (CTDIvo1), table height, whether the localizer image was obtained using the posteroanterior or the anteroposterior technique, arm position, and number of overscanned slices were recorded. RESULTS. For a given patient, the total examination DLP difference comparing the two MDCT studies ranged from 0.1% to 238.0%. For the same patient, total examination DLP was always higher when the localizer image was obtained with the posteroanterior compared with the anteroposterior technique. When table position was closer to the x-ray source, patients appeared magnified in the posteroanterior localizer image (8-29%; average, 14%) and higher tube currents were selected with ATCM. Localizer technique, table height, arm position, number of overscanned slices, and technologist were all significant predictors of dose. CONCLUSION. Patient off-centering closer to the x-ray source resulted in patient magnification in the posteroanterior localizer image, leading to higher tube currents with ATCM and increased DLP. Differences in technologist, arm position, and overscanning also resulted in dose variability.
引用
收藏
页码:377 / 386
页数:10
相关论文
共 14 条
[1]   Radiation Exposure from CT Scans: How to Close Our Knowledge Gaps, Monitor and Safeguard Exposure-Proceedings and Recommendations of the Radiation Dose Summit, Sponsored by NIBIB, February 24-25, 2011 [J].
Boone, John M. ;
Hendee, William R. ;
McNitt-Gray, Michael F. ;
Seltzer, Steven E. .
RADIOLOGY, 2012, 265 (02) :544-554
[2]   Arm Raising at Exposure-controlled Multidetector Trauma CT of Thoracoabdominal Region: Higher Image Quality, Lower Radiation Dose [J].
Brink, Monique ;
de lange, Frank ;
Oostveen, Luuk J. ;
Dekker, Helena M. ;
Kool, Digna R. ;
Deunk, Jaap ;
Edwards, Michael J. R. ;
van Kuijk, Cornelis ;
Kamman, Richard L. ;
Blickman, Johan G. .
RADIOLOGY, 2008, 249 (02) :661-670
[3]   Scanning beyond anatomic limits of the thorax in chest CT: Findings, radiation dose, and automatic tube current modulation [J].
Campbell, J ;
Kalra, MK ;
Rizzo, S ;
Maher, MM ;
Shepard, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (06) :1525-1530
[4]   Radiation Dose for Body CT Protocols: Variability of Scanners at One Institution [J].
Jaffe, Tracy A. ;
Yoshizumi, Terry T. ;
Toncheva, Greta ;
Anderson-Evans, Colin ;
Lowry, Carolyn ;
Miller, Chad M. ;
Nelson, Rendon C. ;
Ravin, Carl E. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (04) :1141-1147
[5]   Techniques and applications of automatic tube current modulation for CT [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Schmidt, B ;
Westerman, BL ;
Morgan, HT ;
Saini, S .
RADIOLOGY, 2004, 233 (03) :649-657
[6]   Radiation from "extra" images acquired with abdominal and/or pelvic CT: Effect of automatic tube current modulation [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Kamath, RS ;
Halpern, EF ;
Saini, S .
RADIOLOGY, 2004, 232 (02) :409-414
[7]   Comparison of z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Kamath, RS ;
Halpern, EF ;
Saini, S .
RADIOLOGY, 2004, 232 (02) :347-353
[8]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628
[9]   Automatic patient centering for MDCT: Effect on radiation dose [J].
Li, Jianhai ;
Udayasankar, Unni K. ;
Toth, Thomas L. ;
Seamans, John ;
Small, William C. ;
Kalra, Mannudeep K. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) :547-552
[10]   Misoperation of CT Automatic Tube Current Modulation Systems with Inappropriate Patient Centering: Phantom Studies [J].
Matsubara, Kosuke ;
Koshida, Kichiro ;
Ichikawa, Katsuhiro ;
Suzuki, Masayuki ;
Takata, Tadanori ;
Yamamoto, Tomoyuki ;
Matsui, Osamu .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) :862-865