DIFFERENT VALSALVA MANOEUVRE PROCEDURES FOR THE DIAGNOSIS OF RIGHT-TO-LEFT SHUNT BY CONTRAST-TRANSCRANIAL DOPPLER

被引:5
作者
Liu, Chao [1 ,2 ]
Lu, Teng [3 ]
Zhai, Ni-Na [1 ]
Bu, Ning [1 ]
Wang, Hu-Qing [1 ]
Chen, Meng-Yi [1 ]
Wu, Hai-Qin [1 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 2, Dept Neurol, Xian 710004, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Affiliated Hosp 2, Dept Educ, Xian, Shaanxi, Peoples R China
[3] Xi An Jiao Tong Univ, Affiliated Hosp 2, Dept Orthopaed, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Right-to-left shunt; Contrast-transcranial Doppler; Valsalva manoeuvre; Contrast agent; PATENT FORAMEN OVALE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; RECURRENT STROKE; ISCHEMIC-STROKE; ULTRASOUND; SONOGRAPHY; AGENT; EVENTS; RISK;
D O I
10.1016/j.ultrasmedbio.2017.04.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The main purpose of this study was to compare two contrast agent injection times during the Valsalva manoeuvre (VM) for the diagnosis of right-to-left shunt using contrast-transcranial Doppler (c-TCD). In total, 992 consecutive patients underwent testing. All patients underwent step 1, and then a coin toss was used to determine the order of steps 2 and 3. The following testing steps were repeated twice: (1) a contrast agent (CA) was infused at rest (CA at rest testing); (2) the VM was initiated immediately after CA injection and released 10 s after CA injection (CA pre-VM testing); and (3) a CA was injected 5 s after initiating the VM, which was released 5 s after CA injection (CA mid-VM testing). For the CA at rest, pre-VM and mid-VM groups, significant differences were observed in the positive right-to-left shunt diagnosis rates (11.49% vs. 23.08% vs. 26.11%, respectively, with an inter-group significance of p < 0.05) and grade classifications (p < 0.05). Although the times to first micro-bubble appearance were similar between the CA at rest and the CA pre-VM groups (8.96 +/- 3.40 s vs. 8.42 +/- 3.72 s, p > 0.05), it was shorter (6.4 +/- 2.75 s, p < 0.05) for the CA mid-VM group than for the other two groups. For the c-TCD testing, the CA mid-VM group yielded different results for diagnosing right-to-left shunts relative to the CA pre-VM group. (C) 2017 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1716 / 1721
页数:6
相关论文
共 31 条
[1]  
[Anonymous], CONSENSUS RIGHT TO L
[2]   VALIDATION OF TRANSCRANIAL DOPPLER SONOGRAPHY IN THE ASSESSMENT OF PATENT FORAMEN OVALE [J].
ANZOLA, GP ;
RENALDINI, E ;
MAGONI, M ;
COSTA, A ;
COBELLI, M ;
GUINDANI, M .
CEREBROVASCULAR DISEASES, 1995, 5 (03) :194-198
[3]   Transcranial Doppler and risk of recurrence in patients with stroke and patent foramen ovale [J].
Anzola, GP ;
Zavarize, P ;
Morandi, E ;
Rozzini, L ;
Parrinello, G .
EUROPEAN JOURNAL OF NEUROLOGY, 2003, 10 (02) :129-135
[4]  
Bickel A, 2007, CLIN NEUROPHYSIOL, V118, pe16
[5]   Transcranial Doppler and Transesophageal Echocardiography: Comparison of Both Techniques and Prospective Clinical Relevance of Transcranial Doppler in Patent Foramen Ovale Detection [J].
Caputi, Luigi ;
Carriero, Maria Rita ;
Falcone, Chiara ;
Parati, Eugenio ;
Piotti, Patrizia ;
Materazzo, Carlo ;
Anzola, Gian Paolo .
JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2009, 18 (05) :343-348
[7]   Morphological and functional characteristics of patent foramen ovale and their embolic implications [J].
De Castro, S ;
Cartoni, D ;
Fiorelli, M ;
Rasura, M ;
Anzini, A ;
Zanette, EM ;
Beccia, M ;
Colonnese, C ;
Fedele, F ;
Fieschi, C ;
Pandian, NG .
STROKE, 2000, 31 (10) :2407-2413
[8]   Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Time window and threshold in microbubble numbers [J].
Droste, DW ;
Silling, K ;
Stypmann, J ;
Grude, M ;
Kemény, V ;
Wichter, T ;
Kühne, K ;
Ringelstein, EB .
STROKE, 2000, 31 (07) :1640-1645
[9]   Right-to-left-shunts detected by transesophageal echocardiography and transcranial Doppler sonography [J].
Droste, DW ;
Schmidt-Rimpler, CS ;
Wichter, T ;
Dittrich, R ;
Ritter, M ;
Stypmann, J ;
Ringelstein, EB .
CEREBROVASCULAR DISEASES, 2004, 17 (2-3) :191-196
[10]   Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts -: Reproducibility, comparison of 2 agents, and distribution of microemboli [J].
Droste, DW ;
Reisener, M ;
Kemény, V ;
Dittrich, R ;
Schulte-Altedorneburg, G ;
Stypmann, J ;
Wichter, T ;
Ringelstein, EB .
STROKE, 1999, 30 (05) :1014-1018