Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement

被引:148
作者
Kluess, Daniel
Martin, Heiner
Mittelmeier, Wolfram
Schmitz, Klaus-Peter
Bader, Rainer
机构
[1] Univ Rostock, Inst Biomed Engn, D-18055 Rostock, Germany
[2] Univ Rostock, Dept Orthopaed Surg, D-18055 Rostock, Germany
关键词
total hip replacement; impingement; dislocation; finite element analysis; range of motion;
D O I
10.1016/j.medengphy.2006.07.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dislocation remains a serious complication of total hip replacement. An insufficient range of motion can lead to impingement of the prosthetic neck on the acetabular cup. Together with the initiation of subluxation and dislocation, recurrent impingement can cause material failure in the liner. The objective of this study was to generate a validated finite element (FE) model capable of predicting the dislocation stability of different femoral head sizes with regard to impingement in different implant positions as well as the corresponding stress distribution in the liner. In order to cover posterior and anterior dislocation, two total hip dislocation associated manoeuvres were simulated using a three-dimensional nonlinear finite element model. The dislocation stability of two head sizes was determined numerically and experimentally. After validation, the FE model was used to analyse the dislocation stability of four different head sizes in variable implant positions. Range of motion (ROM) until impingement, the resisting moment that was developed and ROM until dislocation were evaluated. Additionally, stress distribution within the polyethylene liner during impingement and subluxation was determined. For both dislocation modes, a cup position of 45 degrees lateral abduction and 15 degrees up to 30 degrees anteversion resulted in appropriate ROM and dislocation stability. In general, larger head diameters revealed an increase in ROM and higher resisting moments. Stress analysis showed decreased contact pressures at the egress site of the liners with the larger inner diameters during subluxation. The analysis shows that an optimal implant position and a larger head diameter can reduce the risk of dislocation induced by impingement. The finite element model that was developed enables simplification of design variations compared to experimental studies since prototyping and assembling are replaced by prompt numerical simulation. (c) 2006 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 23 条
[1]   Method for the evaluation of factors influencing the dislocation stability of total hip endoprotheses [J].
Bader, R ;
Scholz, R ;
Steinhauser, E ;
Busch, R ;
Mittlemeier, W .
BIOMEDIZINISCHE TECHNIK, 2004, 49 (05) :137-144
[2]   Differences between the wear couples metal-on-polyethylene and ceramic-on-ceramic in the stability against dislocation of total hip replacement [J].
Bader, R ;
Steinhauser, E ;
Zimmermann, S ;
Mittelmeier, W ;
Scholz, R ;
Busch, R .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2004, 15 (06) :711-718
[3]   Computer-based motion simulation of total hip prostheses with ceramic-on-ceramic wear couple. Analysis of implant design and orientation as influence parameters [J].
Bader, R ;
Steinhauser, E ;
Gradinger, R ;
Willmann, G ;
Mittelmeier, W .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2002, 140 (03) :310-316
[4]   The effect of femoral component head size on posterior dislocation of the artificial hip joint [J].
Bartz, RL ;
Noble, PC ;
Kadakia, NR ;
Tullos, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) :1300-1307
[5]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[6]   Femoral head sizes larger than 32 mm against highly cross-linked polyethylene [J].
Burroughs, BR ;
Rubash, HE ;
Harris, WH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) :150-157
[7]   Femoral head size is a risk factor for total hip luxation -: A study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty Register [J].
Byström, S ;
Espehaug, B ;
Furnes, O ;
Havelin, LI .
ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (05) :514-524
[8]  
EICHMILLER RC, 2001, T SOC BIOM 27 ANN M, P472
[9]   Experimental evaluation of an elastic foundation model to predict contact pressures in knee replacements [J].
Fregly, BJ ;
Bei, YH ;
Sylvester, ME .
JOURNAL OF BIOMECHANICS, 2003, 36 (11) :1659-1668
[10]   The effect of acetabular cup orientations on limiting hip rotation [J].
Kummer, FJ ;
Shah, S ;
Iyer, S ;
DiCesare, PE .
JOURNAL OF ARTHROPLASTY, 1999, 14 (04) :509-513