A Lyapunov-Function Based Controller for 3-Phase Shunt Active Power Filter and Performance Assessment Considering Different System Scenarios

被引:26
作者
Bajaj, Mohit [1 ]
Flah, Aymen [2 ]
Alowaidi, Majed [3 ]
Sharma, Naveen Kumar [4 ]
Mishra, Shailendra [5 ]
Sharma, Sunil Kumar [3 ]
机构
[1] Natl Inst Technol, Delhi 11040, India
[2] Univ Gabes, Natl Sch Engn Gabes, PEESE, Gabes 6029, Tunisia
[3] Majmaah Univ, Coll Comp & Informat Sci, Dept Informat Technol, Al Majmaah 11952, Saudi Arabia
[4] IK Gujral Punjab Tech Univ, Dept Elect Engn, Kapurthala 144603, India
[5] Majmaah Univ, Coll Comp & Informat Sci, Dept Comp Engn, Al Majmaah 11952, Saudi Arabia
关键词
Harmonic analysis; Power harmonic filters; Active filters; Reactive power; Lyapunov methods; Voltage measurement; Capacitors; SAPF; Lyapunov function; harmonic compensation; hysteresis controller; renewable energy; DISTRIBUTED GENERATION; HOSTING CAPACITY; COMPENSATION; ENHANCEMENT; SIMULATION; HARMONICS; ALGORITHM; DESIGN;
D O I
10.1109/ACCESS.2021.3075274
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Shunt active power filter (SAPF) belongs to the class of custom power devices (CPDs) and offers compensation to harmonics originated owing to customer side nonlinear loads, reactive power and unbalance in the distribution power networks functioning in current control mode (CCM). The performance of a SAPF as a harmonic compensator entirely relies on the control technique i.e. the precise detection of the harmonic current components of load that are necessary to be compensated. In the present work, a 3-phase SAPF, inspired by a Lyapunov function based control approach, has been designed for compensation of harmonics resulted in the feeder current owing to the customer side nonlinearity. A control law is determined in the proposed strategy which makes the derivative of the Lyapunov function consistently a negative one for an entire set of stable states. The DC-link capacitor voltage is regulated at constant reference through the proportional-integral (PI) controller. In this method rating of the shunt active power filter is considerably reduced than the other two broadly employed conventional methods. Furthermore, the harmonic compensation efficacy of the proposed Lyapunov function based SAPF is compared with the one based on other two conventional approaches under four different system scenarios namely a simple nonlinear load with and without utility side voltage distortion, a modified IEEE 13 bus test distribution system loaded with a 3-phase chopper fed direct current (DC) motor drive at a single bus and last especially for increasing the harmonic-constrained penetration level of renewable energy. Results obtained through simulation performed in MATLAB/Simulink shows that total harmonic distortion (THD) of source current and dynamic, as well as steady-state performance with Lyapunov function based controller, is significantly improved than the other two conventional methods. Also, the robust compensation performance of the SAPF empowers it to deal with the high penetration of renewable energy.
引用
收藏
页码:66079 / 66102
页数:24
相关论文
共 43 条
[1]  
Akagi H., 1983, P IEEE JIEE INT POW, P821
[2]  
[Anonymous], 1992, IEEE Std. 519
[3]  
[Anonymous], 2018, IEEE Standard for Interconnection and Interoperability of DIstributed Energy Resources with Associated Electric Power Systems Interfaces
[4]  
[Anonymous], 2012, International Journal of Engineering, Science and Technology, DOI [10.4314/ijest.v4i1.9s, DOI 10.4314/IJEST.V4I1.9S]
[5]   NEW CONTROL ALGORITHMS FOR SERIES AND SHUNT 3-PHASE 4-WIRE ACTIVE POWER FILTERS [J].
AREDES, M ;
WATANABE, EH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) :1649-1656
[6]  
Bajaj M., 2013, INT J EMERG TECHNOL, V3, P620
[7]  
Bajaj M., 2020, 7 IEEE UTT PRAD SECT, P1, DOI [10.1109/PIICON49524.2020.9112965, DOI 10.1109/UPCON50219.2020.9376535]
[8]  
Bajaj M, 2015, 2015 ANN IEEE IND C, P1, DOI DOI 10.1109/INDICON.2015.7443406
[9]  
Bajaj M., 2016, P 2016 INT C CIRCUIT, P1, DOI [10.1109/ICCPCT.2016.7530196, DOI 10.1109/ICCPCT.2016.7530196]