Agreement between single-frequency bioimpedance analysis and dual energy x-ray absorptiometry varies based on sex and segmental mass

被引:12
作者
Nickerson, Brett S. [1 ,2 ]
机构
[1] Texas A&M Int Univ, Dept Profess Programs, 5201 Univ Blvd, Laredo, TX 78041 USA
[2] Univ Alabama, Dept Kinesiol, Tuscaloosa, AL USA
关键词
Adiposity; Fat Mass; Fat-Free Mass; Body Fat Percentage; Bioelectrical Impedance; Validation; BIOELECTRICAL-IMPEDANCE ANALYSIS; BODY-COMPOSITION; MULTIFREQUENCY BIOIMPEDANCE; ADULTS; WOMEN; POPULATION; ACCURACY; VALIDITY; MEN;
D O I
10.1016/j.nutres.2018.03.003
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Bioimpedance analysis (BIA) and dual energy X-ray absorptiometry (DXA) are commonly utilized for total and segmental body composition assessment, but the agreement between these methods varies. Group (i.e., constant error [CE]) and individual error (i.e., standard error of estimate [SEE] and 95% limits of agreement [LOAs]) of single-frequency BIA were determined in apparently healthy men and women (n = 28 and 45, respectively) when using DXA as a reference method. It was hypothesized that single-frequency BIA would provide lower error for the estimation of total and segmental FFM than FM and BF%. The CE for many of the total and segmental body composition comparisons revealed statistically significant (all P < .05) mean differences (FMTOTAL, FMLEGS, FFMTOTAL, FFMARMS, FFMLEGS, FFMTRUNK, BF%(TOTAL) and BF%(ARMS) for both sexes as well as FMTRUNK and BF%(TRUNK) for women and FMARMS and FMLEGS for men). Although there were significant CEs for many comparisons, the individual error (i.e., SEEs and 95% LOAs) for total and segmental FFM were small whereas FM and BF% were large. Furthermore, the individual error tended to be larger for men than women when estimating FM and BF%, which is likely attributed to the larger segmental mass of men. This finding indicates the agreement between single-frequency BIA and DXA varies based on sex and segmental mass. Consequently, single-frequency BIA can be used for total and segmental FFM, but is not recommended for FM and BF%. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 26 条
  • [1] Utility of multifrequency bioelectrical impedance compared with dual-energy x-ray absorptiometry for assessment of total and regional body composition varies between men and women
    Anderson, Lindsey J.
    Erceg, David N.
    Schroeder, E. Todd
    [J]. NUTRITION RESEARCH, 2012, 32 (07) : 479 - 485
  • [2] Effect of Exercise Intensity on Percent Body Fat Determined by Leg-to-Leg and Segmental Bioelectrical Impedance Analyses in Adults
    Andreacci, Joseph L.
    Nagle, Trisha
    Fitzgerald, Elise
    Rawson, Eric S.
    Dixon, Curt B.
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2013, 84 (01) : 88 - 95
  • [3] Impact of eating and drinking on body composition measurements by bioelectrical impedance
    Androutsos, O.
    Gerasimidis, K.
    Karanikolou, A.
    Reilly, J. J.
    Edwards, C. A.
    [J]. JOURNAL OF HUMAN NUTRITION AND DIETETICS, 2015, 28 (02) : 165 - 171
  • [4] [Anonymous], 2005, HUMAN BODY COMPOSITI
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Cheuvront S.N., 2005, Sports Science Exchange, V18, P1
  • [7] International physical activity questionnaire:: 12-country reliability and validity
    Craig, CL
    Marshall, AL
    Sjöström, M
    Bauman, AE
    Booth, ML
    Ainsworth, BE
    Pratt, M
    Ekelund, U
    Yngve, A
    Sallis, JF
    Oja, P
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) : 1381 - 1395
  • [8] COMPARISON OF TOTAL AND SEGMENTAL BODY COMPOSITION USING DXA AND MULTIFREQUENCY BIOIMPEDANCE IN COLLEGIATE FEMALE ATHLETES
    Esco, Michael R.
    Snarr, Ronald L.
    Leatherwood, Matthew D.
    Chamberlain, Nik A.
    Redding, Melvenia L.
    Flatt, Andrew A.
    Moon, Jordan R.
    Williford, Henry N.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2015, 29 (04) : 918 - 925
  • [9] THE ACCURACY OF HAND-TO-HAND BIOELECTRICAL IMPEDANCE ANALYSIS IN PREDICTING BODY COMPOSITION IN COLLEGE-AGE FEMALE ATHLETES
    Esco, Michael R.
    Olson, Michele S.
    Williford, Henry N.
    Lizana, Suheil N.
    Russell, Angela R.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (04) : 1040 - 1045
  • [10] Statistical power analyses using G*Power 3.1: Tests for correlation and regression analyses
    Faul, Franz
    Erdfelder, Edgar
    Buchner, Axel
    Lang, Albert-Georg
    [J]. BEHAVIOR RESEARCH METHODS, 2009, 41 (04) : 1149 - 1160