A randomized comparison of pediatric-sized Streamlined Liner of Pharyngeal Airway and Laryngeal Mask Airway-Unique in paralyzed children

被引:5
|
作者
Zhu, Wenxiu [1 ]
Wei, Xinchuan [1 ]
机构
[1] Sichuan Univ, Dept Anesthesiol, West China Hosp, 37 Guoxuexiang, Chengdu 610064, Peoples R China
关键词
laryngeal masks; pediatrics; anesthesiology; oropharyngeal leak pressure; airway management; complications; COBRA PERILARYNGEAL AIRWAY; PRESSURE; VENTILATION; ANESTHESIA; SLIPA(TM); INSERTION; LMA; IMPROVES; TRIAL;
D O I
10.1111/pan.12883
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BackgroundThe pediatric-sized Streamlined Liner of Pharyngeal Airway (SLIPA) is a new supraglottic airway device for children. AimsThe aim of this study was to compare the clinical performance of the pediatric-sized SLIPA with the Laryngeal Mask Airway-Unique in paralyzed children under positive pressure-controlled ventilation (PCV). MethodsOne hundred children, aged 2 months to 12 years with American Society of Anesthesiologists physical status I-II were enrolled and randomly allocated to the SLIPA group or the Laryngeal Mask Airway-Unique group (50 patients in each group). The primary outcome variable was oropharyngeal leak pressure. Other outcome variables were first insertion success rate, insertion time, minor airway interventions required for successful insertion, intraoperative dislodgement, ventilatory data, and perioperative complications. ResultsThe insertion characteristics, ventilation data, and perioperative complications were comparable between the two groups. The leak pressure of the SLIPA was significantly higher than that of the Laryngeal Mask Airway-Unique [median (IQR): 25 (22-30) cmH(2)O vs 21 (19-26) cmH(2)O, respectively; mean sd: 25.3 +/- 4.6 cmH(2)O vs 22.6 +/- 4.8 cmH(2)O, respectively; P = 0.006]. The incidence of intraoperative dislodgment was significantly lower in the SLIPA group than in the Laryngeal Mask Airway-Unique group (0 vs 6 patients, respectively; P = 0.027). ConclusionsIn conclusion, both the SLIPA and the Laryngeal Mask Airway-Unique can be used effectively without severe complications in paralyzed children. Additionally, the SLIPA provides a better airway seal and better intraoperative position stability than the Laryngeal Mask Airway-Unique.
引用
收藏
页码:557 / 563
页数:7
相关论文
共 50 条
  • [21] Insertion methods comparison for The Streamlined Liner of the Pharynx Airway in children by novice
    Chen, Y.
    Bai, J.
    Wang, R.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2018, 62 (03) : 319 - 327
  • [22] Preheating of streamlined liner of pharyngeal airway (SLIPA) reduced the related complications: a randomized control study
    Geng, Guiqi
    Chen, Yingjie
    Liu, Hailian
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (03) : 547 - 550
  • [23] A prospective, randomized trial of the Ambu AuraGain™ laryngeal mask versus the LMA® protector airway in paralyzed, anesthetized adult men
    Moser, Berthold
    Audige, Laurent
    Keller, Christian
    Brimacombe, Joseph
    Gasteiger, Lukas
    Bruppacher, Heinz R.
    MINERVA ANESTESIOLOGICA, 2018, 84 (06) : 684 - 692
  • [24] Randomized comparison of the classic Laryngeal Mask Airway™ with the Airway Management Device™ during anaesthesia
    Cook, TM
    Porter, MV
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 91 (05) : 672 - 677
  • [25] Comparison of laryngeal mask airway and endotracheal tube in general anesthesia in children
    Dong, Wei
    Zhang, Wei
    Er, Jianxu
    Liu, Jiapeng
    Han, Jiange
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2023, 26 (06)
  • [26] Failure of the Laryngeal Mask Airway Unique™ and Classic™ in the Pediatric Surgical Patient A Study of Clinical Predictors and Outcomes
    Mathis, Michael R.
    Haydar, Bishr
    Taylor, Emma L.
    Morris, Michelle
    Malviya, Shobha V.
    Christensen, Robert E.
    Ramachandran, Satya-Krishna
    Kheterpal, Sachin
    ANESTHESIOLOGY, 2013, 119 (06) : 1284 - 1295
  • [27] Performance of the Pediatric-sized i-gel Compared with the Ambu AuraOnce Laryngeal Mask in Anesthetized and Ventilated Children
    Theiler, Lorenz G.
    Kleine-Brueggeney, Maren
    Luepold, Barbara
    Stucki, Franziska
    Seiler, Stefan
    Urwyler, Natalie
    Greif, Robert
    ANESTHESIOLOGY, 2011, 115 (01) : 102 - 110
  • [28] Comparison of the effect-site concentrations of remifentanil for Streamlined Liner of the Pharynx Airway (SLIPA™) versus laryngeal mask airway SoftSeal™ insertion during target-controlled infusion of propofol
    Kim, S. H.
    Choi, E. M.
    Chang, C. H.
    Kim, H. K.
    Chung, M. H.
    Choi, Y. R.
    ANAESTHESIA AND INTENSIVE CARE, 2011, 39 (04) : 611 - 617
  • [29] Airway management in spontaneously breathing anaesthetized children:: comparison of the Laryngeal Mask Airway™ with the cuffed oropharyngeal airway
    Mamaya, B
    PAEDIATRIC ANAESTHESIA, 2002, 12 (05): : 411 - 415
  • [30] Randomized Comparison of Actual and Ideal Body Weight for Size Selection of the Laryngeal Mask Airway Classic in Overweight Patients
    Kim, Min-Soo
    Lee, Jong Seok
    Nam, Sang Beom
    Kang, Hyo Jong
    Kim, Ji Eun
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2015, 30 (08) : 1197 - 1202