Learning effect of Humphrey Matrix frequency doubling technology perimetry in patients with open-angle glaucoma

被引:6
|
作者
Pierre-Filho, Paulo De Tarso [1 ]
Gomes, Paulo R. P. [1 ]
Pierre, Erika T. L. [1 ]
Pierre, Leandro M. [1 ]
机构
[1] Santa Casa Sobral, Dept Ophthalmol, Sobral, Brazil
关键词
Glaucoma; Learning effect; Matrix; Perimetry; Visual field; AUTOMATED PERIMETRY; OCULAR HYPERTENSION; VARIABILITY; THRESHOLD; PATTERN;
D O I
10.1177/112067211002000328
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate the learning effect of frequency doubling technology (FDT) perimetry using the Humphrey Matrix perimeter in patients with open-angle glaucoma with no perimetric experience. Methods. One eye each of 30 glaucoma patients who had no history of visual field testing underwent 3 Matrix tests using 24-2 program with full-threshold strategy. The parameters investigated to detect learning effect were test duration, reliability indexes, mean deviation (MD), pattern standard deviation (PSD), and the number of points with a p of <5% and <1% in the total and pattern deviation maps. Results. MD showed a larger defect at the first test (-13.64 +/- 1.63 dB) than at the second (-12.68 +/- 1.45 dB) and third (-11.69 +/- 1.48 dB) tests (p<0.05). A statistically significant reduction (p<0.05) in the number of points with a p <5% and <1% in the total deviation map was observed when repeating the examination. The values of test duration, PSD, fixation losses, false-positive rate, false-negative rate, and number of points with a p <5% and <1% in the pattern deviation map were not changed significantly (p>0.05). Conclusions. Humphrey Matrix FDT perimetry showed a statistically significant learning effect on MD and the number of significantly depressed points of the total deviation map in glaucoma patients with no perimetric experience. It is probably necessary to obtain at least 3 repetitions to rule out the presence of a learning effect in such patients before providing useful results. (Eur J Ophthalmol 2010; 20: 538-41)
引用
收藏
页码:538 / 541
页数:4
相关论文
共 50 条
  • [41] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Folkert K. Horn
    Nina Wakili
    Anselm M. Jünemann
    Matthias Korth
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 658 - 665
  • [42] Impact of learning effect on reliability factors and global indices in visual field testing by standard automated perimetry in normal healthy subjects and primary open-angle glaucoma patients to obtain an accurate baseline perimetry chart
    Rana, Jagriti
    Singh, Anjali
    Singh, Arti
    Singh, Kamaljeet
    Singh, Shivangi
    Yadav, Vineet Kumar
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (07) : 2739 - 2745
  • [43] Effect of Tafluprost 0.0015% on Central Corneal Thickness in Patients With Primary Open-angle Glaucoma
    Panos, Georgios D.
    Konstantinidis, Aristeidis
    Mendrinos, Efstratios
    Kozobolis, Vassilios
    Perente, Irfan
    Gatzioufas, Zisis
    CURRENT EYE RESEARCH, 2013, 38 (09) : 977 - 982
  • [44] Usefulness of 10-2 Matrix Frequency Doubling Technology Perimetry for Detecting Central Visual Field Defects in Preperimetric Glaucoma Patients
    Jung, Younhea
    Park, Hae-Young L.
    Park, Yi Ryeung
    Park, Chan Kee
    SCIENTIFIC REPORTS, 2017, 7
  • [45] Test-retest variability in glaucoma patients tested with C-20-1 screening-mode frequency doubling technology perimetry
    Brush, MB
    Chen, PP
    JOURNAL OF GLAUCOMA, 2004, 13 (04) : 273 - 277
  • [46] Rarebit perimetry and frequency doubling technology in patients with ocular hypertension
    Corallo, G.
    Iester, M.
    Scotto, R.
    Calabria, G.
    Traverso, C. E.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (02) : 205 - 211
  • [47] Longitudinal Trends in Resource Use in an Incident Cohort of Open-Angle Glaucoma Patients: Resource Use in Open-Angle Glaucoma
    Stein, Joshua D.
    Niziol, Leslie M.
    Musch, David C.
    Lee, Paul P.
    Kotak, Sameer V.
    Peters, Colleen M.
    Kymes, Steven M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (03) : 452 - 459
  • [48] Frequency Doubling Technology Perimetry for Detection of Visual Field Progression in Glaucoma: A Pointwise Linear Regression Analysis
    Liu, Shu
    Yu, Marco
    Weinreb, Robert N.
    Lai, Gilda
    Lam, Dennis Shun-Chiu
    Leung, Christopher Kai-Shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (05) : 2862 - 2869
  • [49] Frequency doubling technology and high-pass resolution perimetry in glaucoma and ocular hypertension
    Kalaboukhova, L
    Lindblom, B
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2003, 81 (03): : 247 - 252
  • [50] Late-Onset Ocular Hypotensive Effect of Ripasudil on Primary Open-Angle Glaucoma
    Sano, Kei
    Terauchi, Ryo
    Fukai, Kota
    Ogawa, Shumpei
    Noro, Takahiko
    Tatemichi, Masayuki
    Nakano, Tadashi
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 3905 - 3912