Learning effect of Humphrey Matrix frequency doubling technology perimetry in patients with open-angle glaucoma

被引:6
|
作者
Pierre-Filho, Paulo De Tarso [1 ]
Gomes, Paulo R. P. [1 ]
Pierre, Erika T. L. [1 ]
Pierre, Leandro M. [1 ]
机构
[1] Santa Casa Sobral, Dept Ophthalmol, Sobral, Brazil
关键词
Glaucoma; Learning effect; Matrix; Perimetry; Visual field; AUTOMATED PERIMETRY; OCULAR HYPERTENSION; VARIABILITY; THRESHOLD; PATTERN;
D O I
10.1177/112067211002000328
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate the learning effect of frequency doubling technology (FDT) perimetry using the Humphrey Matrix perimeter in patients with open-angle glaucoma with no perimetric experience. Methods. One eye each of 30 glaucoma patients who had no history of visual field testing underwent 3 Matrix tests using 24-2 program with full-threshold strategy. The parameters investigated to detect learning effect were test duration, reliability indexes, mean deviation (MD), pattern standard deviation (PSD), and the number of points with a p of <5% and <1% in the total and pattern deviation maps. Results. MD showed a larger defect at the first test (-13.64 +/- 1.63 dB) than at the second (-12.68 +/- 1.45 dB) and third (-11.69 +/- 1.48 dB) tests (p<0.05). A statistically significant reduction (p<0.05) in the number of points with a p <5% and <1% in the total deviation map was observed when repeating the examination. The values of test duration, PSD, fixation losses, false-positive rate, false-negative rate, and number of points with a p <5% and <1% in the pattern deviation map were not changed significantly (p>0.05). Conclusions. Humphrey Matrix FDT perimetry showed a statistically significant learning effect on MD and the number of significantly depressed points of the total deviation map in glaucoma patients with no perimetric experience. It is probably necessary to obtain at least 3 repetitions to rule out the presence of a learning effect in such patients before providing useful results. (Eur J Ophthalmol 2010; 20: 538-41)
引用
收藏
页码:538 / 541
页数:4
相关论文
共 50 条
  • [31] Comparison of Glaucoma Detection Performance of Binocular Perimetry Screening Program Using imo Perimetry With Frequency Doubling Technology
    Nishijima, Euido
    Hosaka, Daisuke
    Ogawa, Shumpei
    Itoh, Yoshinori
    Noro, Takahiko
    Okude, Sachiyo
    Sano, Kei
    Yoshikawa, Keiji
    Tatemichi, Masayuki
    Nakano, Tadashi
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (08):
  • [32] Standard Automated Perimetry versus Matrix Frequency Doubling Technology Perimetry in Subjects with Ocular Hypertension and Healthy Control Subjects
    Lamparter, Julia
    Aliyeva, Shakhsanam
    Schulze, Andreas
    Berres, Manfred
    Pfeiffer, Norbert
    Hoffmann, Esther M.
    PLOS ONE, 2013, 8 (02):
  • [33] Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children
    Kocabeyoglu, Sibel
    Uzun, Salih
    Mocan, Mehmet Cem
    Bozkurt, Banu
    Irkec, Murat
    Orhan, Mehmet
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (10) : 576 - 579
  • [34] The effect of different criteria on the number of patients blind from open-angle glaucoma
    Anders Heijl
    Johan Aspberg
    Boel Bengtsson
    BMC Ophthalmology, 11
  • [35] New perimetric techniques - A comparison between rarebit and frequency doubling technology perimetry in normal subjects and glaucoma patients
    Martin, L
    Wanger, P
    JOURNAL OF GLAUCOMA, 2004, 13 (04) : 268 - 272
  • [36] Comparison of Standard Automated Perimetry, Short-Wavelength Automated Perimetry, and Frequency-Doubling Technology Perimetry to Monitor Glaucoma Progression
    Hu, Rongrong
    Wang, Chenkun
    Gu, Yangshun
    Racette, Lyne
    MEDICINE, 2016, 95 (07) : e2618
  • [37] Matrix metalloproteinases and their inhibitors in the chamber angle of normal eyes and patients with primary open-angle glaucoma and exfoliation glaucoma
    Ronkko, Seppo
    Rekonen, Petri
    Kaarniranta, Kai
    Puustjarvi, Tuomo
    Terasvirta, Markku
    Uusitalo, Hannu
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (05) : 697 - 704
  • [38] Matrix metalloproteinases and their inhibitors in the chamber angle of normal eyes and patients with primary open-angle glaucoma and exfoliation glaucoma
    Seppo Rönkkö
    Petri Rekonen
    Kai Kaarniranta
    Tuomo Puustjärvi
    Markku Teräsvirta
    Hannu Uusitalo
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245
  • [39] Predicting conversion to glaucoma using standard automated perimetry and frequency doubling technology
    Genichiro Takahashi
    Shaban Demirel
    Chris A. Johnson
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2017, 255 : 797 - 803
  • [40] Assessment of depression in patients with open-angle glaucoma
    Cvetkovic, Aleksandra
    Sreckovic, Suncica
    Paunovic, Svetlana
    VOJNOSANITETSKI PREGLED, 2024, 81 (03) : 167 - 175