Learning effect of Humphrey Matrix frequency doubling technology perimetry in patients with open-angle glaucoma

被引:6
|
作者
Pierre-Filho, Paulo De Tarso [1 ]
Gomes, Paulo R. P. [1 ]
Pierre, Erika T. L. [1 ]
Pierre, Leandro M. [1 ]
机构
[1] Santa Casa Sobral, Dept Ophthalmol, Sobral, Brazil
关键词
Glaucoma; Learning effect; Matrix; Perimetry; Visual field; AUTOMATED PERIMETRY; OCULAR HYPERTENSION; VARIABILITY; THRESHOLD; PATTERN;
D O I
10.1177/112067211002000328
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To evaluate the learning effect of frequency doubling technology (FDT) perimetry using the Humphrey Matrix perimeter in patients with open-angle glaucoma with no perimetric experience. Methods. One eye each of 30 glaucoma patients who had no history of visual field testing underwent 3 Matrix tests using 24-2 program with full-threshold strategy. The parameters investigated to detect learning effect were test duration, reliability indexes, mean deviation (MD), pattern standard deviation (PSD), and the number of points with a p of <5% and <1% in the total and pattern deviation maps. Results. MD showed a larger defect at the first test (-13.64 +/- 1.63 dB) than at the second (-12.68 +/- 1.45 dB) and third (-11.69 +/- 1.48 dB) tests (p<0.05). A statistically significant reduction (p<0.05) in the number of points with a p <5% and <1% in the total deviation map was observed when repeating the examination. The values of test duration, PSD, fixation losses, false-positive rate, false-negative rate, and number of points with a p <5% and <1% in the pattern deviation map were not changed significantly (p>0.05). Conclusions. Humphrey Matrix FDT perimetry showed a statistically significant learning effect on MD and the number of significantly depressed points of the total deviation map in glaucoma patients with no perimetric experience. It is probably necessary to obtain at least 3 repetitions to rule out the presence of a learning effect in such patients before providing useful results. (Eur J Ophthalmol 2010; 20: 538-41)
引用
收藏
页码:538 / 541
页数:4
相关论文
共 50 条
  • [21] Discriminating ability of Humphrey Matrix perimetry in early glaucoma patients
    Hong, Samin
    Chung, Woosuk
    Hong, Young Jae
    Seong, Gong Je
    OPHTHALMOLOGICA, 2007, 221 (03) : 195 - 199
  • [22] Predicting conversion to glaucoma using standard automated perimetry and frequency doubling technology
    Takahashi, Genichiro
    Demirel, Shaban
    Johnson, Chris A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (04) : 797 - 803
  • [23] EFFECT OF MYRICETIN ON PRIMARY OPEN-ANGLE GLAUCOMA
    Yang, Qing
    Li, Ying
    Luo, Lin
    TRANSLATIONAL NEUROSCIENCE, 2018, 9 (01) : 132 - 141
  • [24] Predictive value of frequency doubling technology perimetry for detecting glaucoma in a developing country
    Mansberger, SL
    Johnson, CA
    Cioffi, GA
    Choi, D
    Krishnadas, SR
    Srinivasan, M
    Balamurugan, V
    Kim, U
    Smith, SD
    Wilkins, JH
    Gritz, DC
    JOURNAL OF GLAUCOMA, 2005, 14 (02) : 128 - 134
  • [25] Combining Frequency Doubling Technology Perimetry and Scanning Laser Polarimetry for Glaucoma Detection
    Mwanza, Jean-Claude
    Warren, Joshua L.
    Hochberg, Jessica T.
    Budenz, Donald L.
    Chang, Robert T.
    Ramulu, Pradeep Y.
    JOURNAL OF GLAUCOMA, 2015, 24 (08) : 561 - 567
  • [26] Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma
    Kampmeier, J
    Eisert, B
    Buchwald, HJ
    Lang, GK
    Lang, GE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (03) : 157 - 167
  • [27] Relationship between second-generation frequency doubling technology and standard automated perimetry in patients with glaucoma
    Zarkovic, Andrea
    Mora, Justin
    McKelvie, James
    Gamble, Greg
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (09) : 808 - 811
  • [28] FACTORS ASSOCIATED WITH A LEARNING EFFECT IN GLAUCOMA PATIENTS USING AUTOMATED PERIMETRY
    KULZE, JC
    STEWART, WC
    SUTHERLAND, SE
    ACTA OPHTHALMOLOGICA, 1990, 68 (06): : 681 - 686
  • [29] Comparison of Standard Automated Perimetry, Frequency-Doubling Technology Perimetry, and Short-Wavelength Automated Perimetry for Detection of Glaucoma
    Liu, Shu
    Lam, Shi
    Weinreb, Robert N.
    Ye, Cong
    Cheung, Carol Y.
    Lai, Gilda
    Lam, Dennis Shun-Chiu
    Leung, Christopher Kai-Shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7325 - 7331
  • [30] Elevated Matrix Metalloproteinase in Aqueous Humor in Patients with Open-Angle Glaucoma
    Kim, Hyo Won
    Jee, Dong Hyun
    Choi, Jin A.
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (04): : 601 - 606