Electrical impedance tomography guided ventilation therapy

被引:68
作者
Putensen, Christian [1 ]
Wrigge, Hermann [1 ]
Zinserling, Joerg [1 ]
机构
[1] Univ Bonn, Dept Anaesthesiol & Intens Care Med, D-53105 Bonn, Germany
关键词
electrical impedance tomography; imaging; lungs; monitoring; regional ventilation;
D O I
10.1097/MCC.0b013e328136c1e2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
In view of recently published data, it can be concluded that, in critically ill patients, electrical impedance tomography determines reliable regional ventilation. Therefore, this technique has the potential to become a valuable bedside tool.
引用
收藏
页码:344 / 350
页数:7
相关论文
共 31 条
[1]  
ASHBAUGH DG, 1967, LANCET, V2, P319
[2]   Errors in reconstruction of resistivity images using a linear reconstruction technique [J].
Barber, D.C. ;
Brown, B.H. .
Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A) :101-104
[3]   Ventilator-induced lung injury - Lessons from experimental studies [J].
Dreyfuss, D ;
Saumon, G .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (01) :294-323
[4]   Positive end-expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery [J].
Erlandsson, K. ;
Odenstedt, H. ;
Lundin, S. ;
Stenqvist, O. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (07) :833-839
[5]   Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography [J].
Frerichs, I ;
Hahn, G ;
Golisch, W ;
Kurpitz, M ;
Burchardi, H ;
Hellige, G .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1998, 42 (06) :721-726
[6]   Detection of local lung air content by electrical impedance tomography compared with electron beam CT [J].
Frerichs, I ;
Hinz, J ;
Herrmann, P ;
Weisser, G ;
Hahn, G ;
Dudykevych, T ;
Quintel, M ;
Hellige, G .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (02) :660-666
[7]  
GATTINONI L, 1986, INTENS CARE MED, V12, P137
[8]  
Gattinoni L, 1986, J Thorac Imaging, V1, P25, DOI 10.1097/00005382-198607000-00005
[9]   Quantitative evaluation of the performance of different electrical tomography devices [J].
Hahn, G ;
Thiel, F ;
Dudykevych, T ;
Frerichs, I ;
Gersing, E ;
Schröder, T ;
Hartung, C ;
Hellige, G .
BIOMEDIZINISCHE TECHNIK, 2001, 46 (04) :91-95
[10]   Body and head position effects on regional lung ventilation in infants: an electrical impedance tomography study [J].
Heinrich, Sina ;
Schiffmann, Holger ;
Frerichs, Alexander ;
Klockgether-Radke, Adelbert ;
Frerichs, Inez .
INTENSIVE CARE MEDICINE, 2006, 32 (09) :1392-1398