Acceptability of manual versus electric aspiration for first trimester abortion: a randomized trial

被引:25
作者
Dean, G [1 ]
Cardenas, L [1 ]
Darney, P [1 ]
Goldberg, A [1 ]
机构
[1] Univ Calif San Francisco, Ctr Reprod Hlth Res & Policy, Dept Obstet Gynecol & Reprod Sci, San Francisco, CA 94110 USA
关键词
abortion; acceptability; manual uterine aspiration; manual vacuum aspiration; MVA;
D O I
10.1016/S0010-7824(02)00485-7
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
This study was conducted to compare the acceptability of manual and electric vacuum aspiration for first trimester elective abortion. Eighty-four women seeking abortions at less than 10 weeks gestation were randomized to abortion by manual or electric vacuum aspiration. Post-procedure questionnaires were administered to patients to assess pain, noise disturbance and overall satisfaction with the abortion procedure. Physicians reported procedural difficulty, their perceptions of patient discomfort and their overall acceptance of the procedure. Other outcomes included amounts of anesthesia required and complication rates. There were no significant differences in pain levels or satisfaction reported by patients; however, significantly more women in the electric group were bothered by noise (19% vs. 2%, p = 0.03). There were no differences in physician assessments of procedural difficulty; however, there were significantly more times in the electric group that physicians would have preferred manual aspiration (43% vs. 17%, p = 0.02). There were four crossovers from manual to electric, and none from electric to manual. It is concluded that physicians and patients find manual vacuum aspiration as acceptable as electric vacuum aspiration for elective abortions performed at less than 10 weeks gestation. (C) 2003 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:201 / 206
页数:6
相关论文
共 16 条
[1]  
*A GUTTM I, FACTS BRIEF IND AB
[2]   MENSTRUAL EXTRACTION [J].
ATIENZA, MF ;
BURKMAN, RT ;
KING, TM ;
BURNETT, LS ;
LAU, HL ;
PARMLEY, TH ;
WOODRUFF, JD .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1975, 121 (04) :490-495
[3]   VACUUM ASPIRATION WITH THE IPAS MODIFIED GYNECOLOGIC SYRINGE [J].
BALOGH, SA .
CONTRACEPTION, 1983, 27 (01) :63-68
[4]   A TIME AND COST-ANALYSIS OF THE MANAGEMENT OF INCOMPLETE ABORTION WITH MANUAL VACUUM ASPIRATION [J].
BLUMENTHAL, PD ;
REMSBURG, RE .
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1994, 45 (03) :261-267
[5]   IMPROVING ABORTION CARE IN ZAMBIA [J].
BRADLEY, J ;
SIKAZWE, N ;
HEALY, J .
STUDIES IN FAMILY PLANNING, 1991, 22 (06) :391-394
[6]   Comparison of pain and time of procedures with two first-trimester abortion techniques performed by residents and faculty [J].
Edelman, A ;
Nichols, MD ;
Jensen, J .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 184 (07) :1564-1567
[7]  
Gaertner E, 1998, S AFR MED J, V88, P187
[8]   OFFICE TERMINATION OF PREGNANCY BY MENSTRUAL ASPIRATION [J].
HALE, RW ;
KOBARA, TY ;
SHARMA, SD ;
TSUEI, JJ ;
GRAMLICH, EP ;
NAKAYAMA, RT ;
MIESFELD, RR ;
LYONS, HM .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1979, 134 (02) :213-318
[9]   Manual vacuum aspiration, a safe and effective alternative in early pregnancy termination [J].
Hemlin, J ;
Möller, B .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2001, 80 (06) :563-567
[10]  
KIZZA APM, 1990, E AFR MED J, V67, P812