Time resolved optical emission spectroscopy of an HPPMS coating process

被引:13
|
作者
Theiss, S. [1 ]
Bibinov, N. [2 ]
Bagcivan, N. [1 ]
Ewering, M. [1 ]
Awakowicz, P. [2 ]
Bobzin, K. [1 ]
机构
[1] Rhein Westfal TH Aachen, Surface Engn Inst, D-52062 Aachen, Germany
[2] Ruhr Univ Bochum, Inst Elect Engn & Plasma Technol, D-44780 Bochum, Germany
关键词
ELECTRON-IMPACT IONIZATION; CROSS-SECTIONS; ATOMS;
D O I
10.1088/0022-3727/43/7/075205
中图分类号
O59 [应用物理学];
学科分类号
摘要
This paper deals with the time resolved optical emission spectroscopy of a high power pulse magnetron sputtering (HPPMS) physical vapour deposition coating process. With an industrial coating unit CC800/9 HPPMS (CemeCon AG, Wurselen) a (Cr,Al,Si)N coating was deposited. During the coating process, an absolute calibrated Echelle spectrometer (ESA-3000) measured the intensities of the spectral lines of chromium (Cr), aluminium (Al) and molecular bands of nitrogen (N-2). Time resolved measurements enable us to calculate different parameters such as the average velocity of sputtered Al and Cr atoms or the internal plasma parameters electron density n(e) and electron temperature kT(e) with a time resolution of 20 mu s. With these parameters, we determine the ionization rates of Al, Cr, Ar and Kr atoms and the deposition densities of Al and Cr atoms. Thus simulated deposition densities of 1.75 x 10(20) m(-2) s(-1) for chromium and 1.7 x 10(22) m(-2) s(-1) for aluminium are reached.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] SUPERFAST TIME-RESOLVED OPTICAL SPECTROSCOPY
    ROBINSON, AL
    SCIENCE, 1984, 224 (4644) : 43 - 43
  • [12] Time-resolved optical spectroscopy of wood
    D'Andrea, C.
    Farina, A.
    Comelli, D.
    Pifferi, A.
    Taroni, P.
    Valentini, G.
    Cubeddu, R.
    Zoia, L.
    Orlandi, M.
    Kienle, A.
    APPLIED SPECTROSCOPY, 2008, 62 (05) : 569 - 574
  • [13] Time-resolved emission spectroscopy of pyrene derivatives
    Dobkowski, J
    Galievsky, VA
    Jasny, J
    Sazanovich, IV
    POLISH JOURNAL OF CHEMISTRY, 2004, 78 (07) : 961 - 972
  • [14] Time-resolved optical emission spectroscopy of pulsed RF plasmas with copper magnetron sputtering
    Kang, Namjun
    Park, Junghoon
    Oh, Soo-ghee
    Kim, Yongmo
    Han, Jeon-geon
    THIN SOLID FILMS, 2008, 516 (11) : 3460 - 3463
  • [15] Time-resolved optical emission spectroscopy in CO2 nanosecond pulsed discharges
    Ceppelli, M.
    Salden, T. P. W.
    Martini, L. M.
    Dilecce, G.
    Tosi, P.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2021, 30 (11):
  • [16] Optical emission of plasmas in ultraviolet and infrared laser ablation of graphite by time-resolved spectroscopy
    Shinozaki, T
    Ooie, T
    Yano, T
    Yoneda, M
    1ST INTERNATIONAL SYMPOSIUM ON LASER PRECISION MICROFABRICATION, 2000, 4088 : 90 - 93
  • [17] Determination of quenching coefficients in a hydrogen RF discharge by time-resolved optical emission spectroscopy
    Gans, T
    Lin, CC
    Schulz-von der Gathen, V
    Döbele, HF
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2001, 34 (08) : L39 - L42
  • [18] Plasma Process Uniformity Diagnosis Technique Using Optical Emission Spectroscopy With Spatially Resolved Ring Lens
    Kim, In Joong
    Yun, Ilgu
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (09) : 5674 - 5681
  • [19] Plasma process control with optical emission spectroscopy
    Ward, Pamela P.
    International SAMPE Technical Conference, 1995, 27 : 90 - 95
  • [20] Carrier dynamics investigated by time resolved optical spectroscopy
    Luyo, SJ
    Brasil, MSP
    de Carvalho, HB
    de Carvalho, W
    Bernussi, AA
    BRAZILIAN JOURNAL OF PHYSICS, 2002, 32 (02) : 353 - 355