Fast and accurate method for estimating power systems phasors using DFT with interpolation

被引:0
|
作者
Nguyen, T. T. [1 ]
Li, X. J. [1 ]
机构
[1] Univ Western Australia, Sch Elect Elect & Comp Engn, Crawley, WA, Australia
来源
2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9 | 2006年
关键词
discrete Fourier transform (DFT); phasor measurement; interpolation; leakage error;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The paper develops a method based on waveform. interpolation in the discrete time-domain to counter the spectral leakage errors arising in forming, by discrete Fourier transform (DFT), the supply frequency phasors representing power system voltages and currents when there are system frequency deviations from the nominal value. The interpolation scheme allows DIRT evaluation to be performed with a time window length which is exactly equal to the fundamental period of the voltage or current waveform. The applications of the method developed include numerical protection where supply frequency phasors are required and synchronized phasor measurements for control functions in power systems. Comparative studies presented in the paper confirm the improvements achieved by the method proposed over other previously-published techniques in terms of accuracy and computing time.
引用
收藏
页码:3167 / +
页数:3
相关论文
共 50 条
  • [1] Fast algorithm for estimating power frequency phasors under power system transients
    Yang, Liming
    Jiao, Zaibin
    Kang, Xiaoning
    Song, Guobing
    Suonan, Jiale
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (04) : 395 - 403
  • [2] Fast and Accurate Frequency Meter Using the Interpolated DFT Method
    Oliwa, Wojciech
    Wieczorek, Grzegorz
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2017, 23 (03) : 43 - 46
  • [3] Proposal of an Accurate and Low Complexity Method for Frequency Estimation Using DFT Interpolation
    Arva, Mihai Catalin
    Bizon, Nicu
    Micu, Augustin
    2017 40TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2017, : 474 - 479
  • [4] Fast and accurate method to measure interharmonics in power systems
    Dai, X
    Gretsch, R
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 1996, 6 (03): : 169 - 174
  • [5] FAST ACCURATE METHOD FOR OUTAGE STUDIES IN POWER-SYSTEMS
    MAMANDUR, KRC
    BERG, GJ
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (03): : 763 - 764
  • [6] Adaptive algorithm for estimating power frequency phasors using dynamic window length
    Yang, Liming
    Jiao, Zaibin
    Kang, Xiaoning
    Song, Guobing
    Suonan, Jiale
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (14) : 3423 - 3430
  • [7] Analysis of asymmetrical faults in power systems using dynamic phasors
    Stankovic, AM
    Aydin, T
    2000 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-4, 2000, : 1957 - 1957
  • [8] Analysis of asymmetrical faults in power systems using dynamic phasors
    Stankovic, AM
    Aydin, T
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (03) : 1062 - 1068
  • [9] A Fast and Accurate Frequency Estimator for Complex Single-Tone Signal Based on DFT Interpolation
    Wang, Mingjiang
    Wang, Qiujun
    Wen, Yinghong
    Liang, Kun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 11
  • [10] An experiment for estimating accurate states in distributed power systems
    Department of Electrical Engineering, St. John's University, Taipei, Taiwan
    不详
    不详
    IEICE Trans Fund Electron Commun Comput Sci, 1600, 3 (1015-1018):