Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population

被引:32
|
作者
Son, Hyeck-Soo [1 ]
Kim, Seong Ho [2 ]
Auffarth, Gerd U. [1 ]
Choi, Chul Young [2 ]
机构
[1] Heidelberg Univ, IVCRC, Dept Ophthalmol, Heidelberg, Germany
[2] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Ophthalmol, 29 Saemunan Ro, Seoul 03181, South Korea
关键词
Extended depth of focus IOL; Symfony; ZXR00; Visual acuity tolerance to postoperative refractive errors; QUALITY-OF-LIFE; VISUAL OUTCOMES; BILATERAL IMPLANTATION; CLINICAL-OUTCOMES; CATARACT-SURGERY; NEW-GENERATION; CONTRAST SENSITIVITY; ROTATIONAL STABILITY; READING PERFORMANCE; OPTICAL-PERFORMANCE;
D O I
10.1186/s12886-019-1193-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 +/- 0.07, 0.09 +/- 0.15, and 0.24 +/- 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of - 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within +/- 0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within - 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than - 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform.
引用
收藏
页数:10
相关论文
共 38 条
  • [31] Visual, Refractive, Functional, and Patient Satisfaction Outcomes After Implantation of a New Extended Depth-of-Focus Intraocular Lens
    Gil, Javier Ferrando
    Irazola, Adela Churruca
    Reparaz, Iraia
    Lauzirika, Gorka
    Martinez-Soroa, Itziar
    Mendicute, Javier
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 3801 - 3813
  • [32] A comparative study of two presbyopia-correcting intraocular lenses combining bifocal and extended depth-of-focus profiles
    Kim, Jeongmin
    Kim, Tae-im
    Seo, Kyoung Yul
    Tchah, Hungwon
    Koh, Kyungmin
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [33] Visual Function after Implantation of Diffractive Extended Depth-of-Focus Intraocular Lenses in Eyes with Primary Open-Angle Glaucoma
    Bissen-Miyajima, Hiroko
    Ota, Yuka
    Taira, Yoko
    Takemura, Ryo
    Minami, Keiichiro
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (06) : 3099 - 3108
  • [34] Visual Function after Implantation of Diffractive Extended Depth-of-Focus Intraocular Lenses in Eyes with Primary Open-Angle Glaucoma
    Hiroko Bissen-Miyajima
    Yuka Ota
    Yoko Taira
    Ryo Takemura
    Keiichiro Minami
    Ophthalmology and Therapy, 2023, 12 : 3099 - 3108
  • [35] Visual and patient-reported factors leading to satisfaction after implantation of diffractive extended depth-of-focus and trifocal intraocular lenses
    Lwowski, Christoph
    Pawlowicz, Katarzyna
    Petermann, Kerstin
    Hemkeppler, Eva
    Hinzelmann, Lisa
    Boehm, Myriam
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (04): : 421 - 428
  • [36] Binocular visual function after staged implantation of extended-depth-of-focus intraocular lens targeting emmetropia and-0.5 diopter: A prospective comparison
    Ota, Yuka
    Bissen-Miyajima, Hiroko
    Nakamura, Kunihiko
    Hirasawa, Manabu
    Minami, Keiichiro
    PLOS ONE, 2020, 15 (08):
  • [37] Evaluation of Visual and Patient-Reported Outcomes, Spectacle Dependence after Bilateral Implantation with a Non-Diffractive Extended Depth of Focus Intraocular Lens Compared to Other Intraocular Lenses
    Dolowiec-Kwapisz, Anna
    Piotrowska, Halina
    Misiuk-Hojlo, Marta
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (17)
  • [38] Visual outcomes and safety after bilateral implantation of a trifocal presbyopia correcting intraocular lens in a Korean population: a prospective single-arm study
    Kim, Tae-im
    Chung, Tae-Young
    Kim, Myoung Joon
    Lee, Kyounghwa
    Hyon, Joon Young
    BMC OPHTHALMOLOGY, 2020, 20 (01)