Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population

被引:32
|
作者
Son, Hyeck-Soo [1 ]
Kim, Seong Ho [2 ]
Auffarth, Gerd U. [1 ]
Choi, Chul Young [2 ]
机构
[1] Heidelberg Univ, IVCRC, Dept Ophthalmol, Heidelberg, Germany
[2] Sungkyunkwan Univ, Sch Med, Kangbuk Samsung Hosp, Dept Ophthalmol, 29 Saemunan Ro, Seoul 03181, South Korea
关键词
Extended depth of focus IOL; Symfony; ZXR00; Visual acuity tolerance to postoperative refractive errors; QUALITY-OF-LIFE; VISUAL OUTCOMES; BILATERAL IMPLANTATION; CLINICAL-OUTCOMES; CATARACT-SURGERY; NEW-GENERATION; CONTRAST SENSITIVITY; ROTATIONAL STABILITY; READING PERFORMANCE; OPTICAL-PERFORMANCE;
D O I
10.1186/s12886-019-1193-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 +/- 0.07, 0.09 +/- 0.15, and 0.24 +/- 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of - 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within +/- 0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within - 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than - 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform.
引用
收藏
页数:10
相关论文
共 38 条
  • [21] Refractive and Visual Outcomes After Implantation of a Secondary Sulcus Intraocular Lens with an Extended Depth of Focus
    Gundersen, Kjell Gunnar
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1861 - 1869
  • [22] Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics
    Sakisaka, Toshihiro
    Minami, Keiichiro
    Takada, Keita
    Mori, Yosai
    Miyata, Kazunori
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [23] Tolerance to decentration of biaspheric intraocular lenses with refractive phase-ring extended depth of focus and diffractive trifocal designs
    Cervino, Alejandro
    Esteve-Taboada, Jose Juan
    Chiu, Yi-Feng
    Yang, Chuan-Hui
    Tseng, Wen-Chu
    Lee, William
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (08) : 2541 - 2550
  • [24] Evaluation of Visual, Refractive, and Functional Outcomes after Implantation of an Extended Depth of Focus Intraocular Lens in Patients with Stable and Mild Glaucoma
    Urcola, Aritz
    Lauzirika, Gorka
    Illarramendi, Igor
    Soto-Velasco, Andrea
    Sanchez-Avila, Ronald
    Fuente-Garcia, Carlota
    Fernandez-Garcia, Aitor
    OPHTHALMOLOGY AND THERAPY, 2025, : 1039 - 1051
  • [25] Prospective Comparison of Clinical Outcomes After Bilateral Implantation of Diffractive Trifocal Extended Depth-of-Focus and Diffractive Trifocal Hydrophobic Intraocular Lenses
    Nagy, Zoltan Z.
    Dorman, Peter
    Szalczer, Szilard
    Kiss, Huba
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (02)
  • [26] Clinical Outcomes after Implantation of a Novel Binocular Complementary Extended Depth-of-Focus Intraocular Lens Compared to Bilateral Low Near-Add Multifocal Intraocular Lenses
    Ivellio-Vellin, Hannah
    Ruiss, Manuel
    Hienert, Julius
    Georgiev, Stefan
    Pilwachs, Caroline
    Fisus, Andreea
    Findl, Oliver
    OPHTHALMIC RESEARCH, 2024, 67 (01) : 549 - 557
  • [27] Clinical Performance of Extended Depth of Focus (EDOF) Intraocular Lenses - A Retrospective Comparative Study of Mini Well Ready and Symfony
    Nowik, Katarzyna Ewa
    Nowik, Kamil
    Kanclerz, Piotr
    Szaflik, Jacek Pawel
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1613 - 1621
  • [28] Silver mean sequence in extended depth of focus intraocular lenses: a comparative study of kinoform and stepwise designs
    Martinez-espert, Anabel
    Ferrando, Vicente
    Garmendia-martinez, Adrian
    Munoz-perez, Francisco m.
    Monsoriu, Juan a.
    Furlan, Walter d.
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (12): : 6999 - 7012
  • [29] Visual outcomes of non-diffractive extended-depth-of-focus and enhanced monofocal intraocular lenses: A case-control study
    Sabur, Huri
    Unsal, Ugur
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (01) : 262 - 268
  • [30] Functional visual acuity after implantation of diffractive extended depth-of-focus intraocular lenses using an echelett optics
    Toshihiro Sakisaka
    Keiichiro Minami
    Keita Takada
    Yosai Mori
    Kazunori Miyata
    BMC Ophthalmology, 21