A portable liquid scintillation counter for general LSC and high sensitivity alpha-counting applications

被引:8
作者
Haaslahti, J [1 ]
Aalto, J [1 ]
Oikari, T [1 ]
机构
[1] Hidex Oy, FIN-20750 Turku, Finland
关键词
Radon; Liquid Scintillation; Scintillation Counter; Graphical Operation; Dimensional Graph;
D O I
10.1023/A:1016005526087
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Applicability of a new portable. single tube liquid scintillation (LS) spectrometer was demonstrated for general LS applications, such as wipe tests and low level alpha counting, especially radon (Rn-222) measurements in water. Wipe tests were performed with wad sticks. They were counted conventionally in a small Volume in Eppendorf tubes with less than 200 mul of LS cocktail, thus minimizing costs and waste. Small volume is specially recommended because low background can be achieved without heavy lead shielding, thus maintaining portability. Typical NRC recommended LLD's were reached for H-3 and other typical LS isotopes. For Rn-222 in water a biphasic extraction system was adopted where radon is extracted from water into a water-immiscible LS cocktail. The method is sensitive because radon can be extracted from a large water volume. It was observed that common non-evaporating "safe" cocktails with di-isopropyl naphtalene solvent are convenient to use and quite suitable for extraction. Also the isotope Ra-226 can be reliably measured via production of its daughter Rn-222. The instrument includes pulse shape electronics to perform alpha/beta separation. This is based on the fact that in LS cocktails alphas generate pulses with longer duration than betas. The alpha/beta separation can be visualized with a two dimensional graph where the x-axis represents pulse amplitude (MCA channels) and the y-axis its length. The graphical operations are all done in standard Excel/Windows environment. Due to their longer pulses, alphas have greater y-coordinates than betas with the same x-coordinate (amplitude). With this graph, one can select a region occupied only by alphas and exclude betas. The above mentioned "safe" cocktails posses good alpha/beta separation properties, Because natural background (cosmic-rays and environmental gammas) produces beta-like pulses. they can be stripped away giving low background for alpha counting, typically a few counts per hour for the extraction samples. The LLD for Rn-222 was 0.1 Bq/l.
引用
收藏
页码:377 / 381
页数:5
相关论文
共 5 条
[1]  
CHALUBNIK S, 1994, ADV LIQUID SCINTILLA, P103
[2]  
HORIUCHI K, 1992, ADV LIQUID SCINTILLA, P383
[3]  
KUOSA H, COMMUNICATION
[4]  
MARSHALL BJ, 1984, LANCET, V1, P1311
[5]  
OIKARI T, 1987, APPL RADIAT ISOTOPES, V38, P875, DOI 10.1016/0883-2889(87)90187-0