Lab-on-a-chip methods for point-of-care measurements of salivary biomarkers of periodontitis

被引:92
作者
Christodoulides, Nicolaos
Floriano, Pierre N.
Miller, Craig S.
Ebersole, Jeffrey L.
Mohanty, Sanghamitra
Dharshan, Priya
Griffin, Michael
Lennart, Alexis
Ballard, Karri L. Michael
King, Charles P., Jr.
Langub, M. Chris
Kryscio, Richard J.
Thomas, Mark V.
McDevitt, John T.
机构
[1] Univ Texas, Dept Chem & Biochem, Austin, TX 78712 USA
[2] Univ Kentucky, Coll Dent, Dept Oral Hlth Practice, Lexington, KY USA
[3] Univ Kentucky, Coll Dent, Ctr Oral Hlth Res, Lexington, KY USA
[4] Univ Kentucky, Dept Microbiol Immunol & Mol Genet, Lexington, KY USA
[5] Univ Kentucky, Dept Internal Med, Lexington, KY USA
[6] Ctr Dis Control & Prevent, Off Extramural Programs, NIOSH, Atlanta, GA USA
[7] Univ Kentucky, Coll Med, Dept Internal Med, Lexington, KY USA
[8] Univ Kentucky, Coll Publ Hlth, Dept Biostat, Lexington, KY USA
[9] Univ Texas, Ctr Nano & Mol Sci & Technol, Austin, TX 78712 USA
[10] Univ Texas, Texas Mat Inst, Austin, TX 78712 USA
来源
ORAL-BASED DIAGNOSTICS | 2007年 / 1098卷
关键词
lab-on-a-chip; salivary diagnostics; inflammation; biomarkers; periodontitis;
D O I
10.1196/annals.1384.035
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Salivary secretions contain a variety of molecules that reflect important pathophysiological activities. Quantitative changes of specific salivary biomarkers could have significance in the diagnosis and management of both oral and systemic diseases. Modern point-of-care technologies with enhanced detection capabilities are needed to implement a significant advancement in salivary diagnostics. One such promising technology is the recently described lab-on-a-chip (LOC) assay system, in which assays are performed on chemically sensitized beads populated into etched silicon wafers with embedded fluid handling and optical detection capabilities. Using this LOC system, complex assays can be performed with small sample volumes, short analysis times, and markedly reduced reagent costs. This report describes the use of LOC methodologies to assess the levels of interleukin-1 beta (IL-1 beta), C-reactive protein (CRP), and matrix metalloproteinase-8 (MMP-8) in whole saliva, and the potential use of these biomarkers for diagnosing and categorizing the severity and extent of periodontitis. This study demonstrates that the results achieved by the LOC approach are in agreement with those acquired with standard enzyme-linked immunosorbent assay (ELISA), with significant IL-1 beta and MMP-8 elevations in whole saliva of periodontitis patients. Furthermore, because of the superior detection capacities associated with the LOC approach, unlike those with ELISA, significant differences in CRP levels between periodontitis patients and normal subjects are observed. Finally, principal component analysis (PCA) is performed to yield an efficient method to discriminate between periodontally healthy and unhealthy patients, thus increasing the diagnostic value of these biomarkers for periodontitis when examined with the integrated LOC sensor system.
引用
收藏
页码:411 / 428
页数:18
相关论文
共 54 条
  • [1] Ajwani S, 2003, Gerodontology, V20, P32, DOI 10.1111/j.1741-2358.2003.00032.x
  • [2] DNA hybridization and discrimination of single-nucleotide mismatches using chip-based microbead arrays
    Ali, MF
    Kirby, R
    Goodey, AP
    Rodriguez, MD
    Ellington, AD
    Neikirk, DP
    McDevitt, JT
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (18) : 4732 - 4739
  • [3] ARCHIBALD DW, 1986, BLOOD, V67, P831
  • [4] Assuma R, 1998, J IMMUNOL, V160, P403
  • [5] BREIMER DD, 1980, PHARM INT, V1, P9
  • [6] CADDY B, 1984, ADV ANAL TOXICOLOGY, V1, P198
  • [7] Application of microchip assay system for the measurement of C-reactive protein in human saliva
    Christodoulides, N
    Mohanty, S
    Miller, CS
    Langub, MC
    Floriano, PN
    Dharshan, P
    Ali, MF
    Bernard, B
    Romanovicz, D
    Anslyn, E
    Fox, PC
    McDevitt, JT
    [J]. LAB ON A CHIP, 2005, 5 (03) : 261 - 269
  • [8] Toward the development of a lab-on-a-chip dual-function leukocyte and C-reactive protein analysis method for the assessment of inflammation and cardiac risk
    Christodoulides, N
    Floriano, PN
    Acosta, SA
    Ballard, KLM
    Weigum, SE
    Mohanty, S
    Dharshan, P
    Romanovicz, D
    McDevitt, JT
    [J]. CLINICAL CHEMISTRY, 2005, 51 (12) : 2391 - 2395
  • [9] A microchip-based multianalyte assay system for the assessment of cardiac risk
    Christodoulides, N
    Tran, M
    Floriano, PN
    Rodriguez, M
    Goodey, A
    Ali, M
    Neikirk, D
    McDevitt, JT
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (13) : 3030 - 3036
  • [10] DETECTION OF CORTICOSTEROID BINDING GLOBULIN IN PAROTID FLUIDS - EVIDENCE FOR THE PRESENCE OF BOTH PROTEIN-BOUND AND NON-PROTEIN-BOUND (FREE) STEROIDS IN UNCONTAMINATED SALIVA
    CHU, FW
    EKINS, RP
    [J]. ACTA ENDOCRINOLOGICA, 1988, 119 (01): : 56 - 60