Quantification of glucose diffusion in arterial tissues by using optical coherence tomography

被引:63
作者
Larin, K. V. [1 ]
Ghosn, M. G.
Ivers, S. N.
Tellez, A.
Granada, J. F.
机构
[1] Univ Houston, Biomed Engn Program, Houston, TX 77004 USA
[2] Saratov NG Chernyshevskii State Univ, Saratov, Russia
[3] Methodist DeBakey Heart Ctr, Houston, TX USA
[4] Methodist Hosp Res Inst, Houston, TX USA
关键词
noninvasive; diffusion; artery; glucose; optical coherence tomography;
D O I
10.1002/lapl.200610111
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Several investigations suggest. that the early stages of atherosclerosis are modulated by the selective permeability of the vascular tissue to pro-inflammatory molecules of different molecular weights. Up to date, a few experiments have been performed to study the permeability of arterial tissue to different molecules. This is primarily due to an absence of an experimental technique capable of depth-resolved, accurate and sensitive assessment of arterial permeability. In this paper, we report our pilot results on nondestructive quantification of glucose diffusion in animal arteries in vitro by using optical coherence tomography (OCT) technique. Permeability of glucose in animal's aorta was estimated to be 1.43 +/- 0.24 x 10(-5) cm/sec from five independent experiments. Obtained results suggest capability of OCT technique for highly sensitive, accurate, and nondestructive monitoring and quantification of agents' diffusion in vascular tissues.
引用
收藏
页码:312 / 317
页数:6
相关论文
共 51 条
  • [1] Boppart SA, 1996, CIRCULATION, V94, P2828
  • [2] Particle deposition in arteries ex vivo:: Effects of pressure, flow, and waveform
    Chesler, NC
    Enyinna, OC
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (03): : 389 - 394
  • [3] The role of shear stress in the pathogenesis of atherosclerosis
    Cunningham, KS
    Gotlieb, AI
    [J]. LABORATORY INVESTIGATION, 2005, 85 (01) : 9 - 23
  • [4] Simulated lipoprotein transport in the wall of branched arteries
    Darbeau, MZ
    Lutz, RJ
    Collins, WE
    [J]. ASAIO JOURNAL, 2000, 46 (06) : 669 - 678
  • [5] DUNCAN DD, 1990, ASME, V112, P183
  • [6] Noninvasive monitoring of glucose concentration with optical coherence tomography
    Esenaliev, RO
    Larin, KV
    Larina, IV
    Motamedi, M
    [J]. OPTICS LETTERS, 2001, 26 (13) : 992 - 994
  • [7] Computational Modeling of mass transfer and links to atherosclerosis
    Ethier, CR
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2002, 30 (04) : 461 - 471
  • [8] Pathogenesis of atherosclerosis
    Falk, E
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (08) : C7 - C12
  • [9] Fercher AF, 2003, REP PROG PHYS, V66, P239, DOI 10.2184/lsj.31.635
  • [10] WHITE-LIGHT INTERFEROMETRIC THICKNESS GAUGE
    FLOURNOY, PA
    WYNTJES, G
    MCCLURE, RW
    [J]. APPLIED OPTICS, 1972, 11 (09): : 1907 - &