Effects of uniformities of deposition of respirable particles on filters on determining their quartz contents by using the direct on-filter X-ray diffraction (DOF XRD) method

被引:8
作者
Chen, Ching-Hwa [1 ]
Tsaia, Perng-Jy [1 ,2 ]
Lai, Chane-Yu [3 ,4 ]
Peng, Ya-Lian [1 ]
Soo, Jhy-Charm [1 ]
Chen, Cheng-Yao [5 ]
Shih, Tung-Sheng [5 ]
机构
[1] Natl Cheng Kung Univ, Coll Med, Dept Environm & Occupat Hlth, Tainan 70101, Taiwan
[2] Natl Cheng Kung Univ, Sustainable Environm Res Ctr, Tainan 70101, Taiwan
[3] Chung Shan Med Univ, Dept Occupat Safety & Hlth, Taichung, Taiwan
[4] Chung Shan Med Univ Hosp, Dept Occupat Med, Taichung, Taiwan
[5] Inst Occupat Safety & Hlth, Shijr City, Taipei, Taiwan
关键词
Quartz; Direct on-filter; X-ray diffraction; ALPHA-QUARTZ; SILICA;
D O I
10.1016/j.jhazmat.2009.11.042
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, field samplings were conducted in three workplaces of a foundry plant, including the molding, demolding, and bead blasting, respectively. Three respirable aerosol samplers (including a 25-mm aluminum cyclone, nylon cyclone, and IOSH cyclone) were used side-by-side to collect samples from each selected workplace. For each collected sample, the uniformity of the deposition of respirable dusts on the filter was measured and its free silica content was determined by both the DOF XRD method and NIOSH 7500 XRD method (i.e., the reference method). A same trend in measured uniformities can be found in all selected workplaces: 25-mm aluminum cyclone > nylon cyclone > IOSH cyclone. Even for samples collected by the sampler with the highest uniformity (i.e., 25-mm aluminum cyclone), the use of the DOF XRD method would lead to the measured free silica concentrations 1.15-2.89 times in magnitude higher than that of the reference method. A new filter holder should be developed with the minimum uniformity comparable to that of NIOSH 7500 XRD method (=0.78) in the future. The use of conversion factors for correcting quartz concentrations obtained from the DOF XRD method based on the measured uniformities could be suitable for the foundry industry at this stage. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:389 / 394
页数:6
相关论文
共 18 条
[1]  
BIGGINS PDE, 1982, BCIRA J, V30, P235
[2]   THE REDUCTION OF DUST LOSSES WITHIN THE CASSETTE OF THE SIMPEDS PERSONAL DUST SAMPLER [J].
BLACKFORD, DB ;
HARRIS, GW ;
REVELL, G .
ANNALS OF OCCUPATIONAL HYGIENE, 1985, 29 (02) :169-180
[3]  
Chernick M R., 2008, Bootstrap methods: a guide for practitioners and researchers, P1
[4]  
HALL P, 1992, BOOTSTRAP EDGEWORTH, P1
[5]  
*HLTH SAF EX, 2005, 101 HLTH SAF EX
[6]   Comparison of direct (X-ray diffraction and infrared spectrophotometry) and indirect (infrared spectrophotometry) methods for the analysis of α-quartz in airborne dusts [J].
Kauffer, E ;
Masson, A ;
Moulut, JC ;
Lecaque, T ;
Protois, JC .
ANNALS OF OCCUPATIONAL HYGIENE, 2005, 49 (08) :661-671
[7]  
KOHYAMA N, 1985, Industrial Health, V23, P221
[8]   Determination of uniformity of filter deposits [J].
Lai, Chane-Yu ;
Kuo, Yu-Mei ;
Hwang, Jing-Shiang ;
Shih, Tung-Sheng ;
Chen, Chih-Chieh .
AEROSOL SCIENCE AND TECHNOLOGY, 2006, 40 (08) :607-614
[9]  
MOONEY CZ, 1993, BOOTSTRAPPING NONPAR, P1
[10]  
*NAT I OCC SAF HLT, 2003, 7500 DHHS NIOSH