Application of a new nanoporous sorbent for extraction and pre-concentration of lead and copper ions

被引:39
|
作者
Zarezade, Vahid [1 ]
Aliakbari, Azam [2 ]
Es'haghi, Moosa [3 ]
Amini, Mostafa M. [2 ]
Behbahani, Mohammad [4 ]
Omidi, Fariborz [5 ]
Hesam, Ghasem [6 ]
机构
[1] Behbahan Fac Med Sci, Behbahan, Iran
[2] Shahid Beheshti Univ, Dept Chem, Tehran, Iran
[3] Islamic Azad Univ, Tabriz Branch, Dept Chem, Tabriz, Iran
[4] Kermanshah Univ Med Sci, RCEDH, Kermanshah, Iran
[5] Univ Tehran Med Sci, Sch Publ Hlth, Dept Occupat Hlth Engn, Tehran, Iran
[6] Shahroud Univ Med Sci, Sch Publ Hlth, Dept Occupat Hlth Engn, Shahroud, Iran
关键词
Siliceous mesocellular foam; mesoporous solid-phase; dithizone; lead and copper ions; fish and water samples; SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; HEAVY-METAL IONS; ACTIVATED CARBON CLOTH; ENVIRONMENTAL-SAMPLES; TRACE DETERMINATION; WATER SAMPLES; BIOLOGICAL SAMPLES; CADMIUM IONS; SILICA FOAMS;
D O I
10.1080/03067319.2017.1315638
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors describe a method for the trace determination of copper (II) and lead (II) in water and fish samples using solid-phase extraction via siliceous mesocellular foam functionalised by dithizone. Siliceous mesocellular was functionalised with dithizone, and the resulting sorbent was characterised by scanning electron microscopy, surface area analysis, thermogravimetric/differential thermal analysis and FTIR. Following solid-phase extraction of target ions by the sorbent, copper and lead ions were quantified by flame atomic absorption spectrometry. Factors affecting the sorption and desorption of target ions by the sorbent were evaluated and optimised. The calibration plot is linear in the 1 - 500 mu g L-1 copper (II) and 3-700 mu g L-1 lead (II) concentration range. The relative recovery efficiency in real sample analysis is in the range from 96 to 102%, and precision varies between 1.7 and 2.8%. It is should be noted that the limits of detection for the copper and lead analysis were 0.8 and 1.6 mu g L-1, respectively. Also, the adsorption capacities for copper and lead ions were 120 and 160 mg g(-1), respectively. The obtained pre-concentration factor for the lead and copper ions by the proposed solid-phase extraction was 75. The method was successfully applied to the determination of low levels of copper (II) and lead (II) in tap, Caspian sea, Persian gulf and lake water and also their detection in fish samples.
引用
收藏
页码:383 / 397
页数:15
相关论文
共 50 条
  • [31] Application of ion-imprinted polymer synthesized by precipitation polymerization as an efficient and selective sorbent for separation and pre-concentration of chromium ions from some real samples
    Roushani, Mahmoud
    Saedi, Zahra
    Hamdi, Fatemeh
    Rajabi, Hamid Reza
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2018, 15 (10) : 2241 - 2249
  • [32] CO-extraction of lead and cadmium by cloud point extraction as a pre-concentration method for analysis by square wave stripping voltammetry
    Hawkins, Megan
    Quartermaine, Cooper
    Bange, Adam
    Rusinek, Cory
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [33] Application of Modified Organo-Nanoclay as the Sorbent for Zinc Determination by FAAS: An Optimization Study of an Online Pre-concentration System
    Khajeh, Mostafa
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2012, 145 (01) : 118 - 125
  • [34] Application of Modified Organo-Nanoclay as the Sorbent for Zinc Determination by FAAS: An Optimization Study of an Online Pre-concentration System
    Mostafa Khajeh
    Biological Trace Element Research, 2012, 145 : 118 - 125
  • [35] COMPARISON OF DIFFERENT PRE-CONCENTRATION METHODS FOR THE DETERMINATION OF TRACE LEVELS OF ARSENIC, CADMIUM, COPPER, MERCURY, LEAD AND SELENIUM
    MENTASTI, E
    NICOLOTTI, A
    PORTA, V
    SARZANINI, C
    ANALYST, 1989, 114 (09) : 1113 - 1117
  • [36] Beneficiation of a low grade lead ore by gravity pre-concentration and flotation
    Liu, Siqing
    Li, Xiujuan
    Zhao, Yang
    Li, Tingting
    APPLIED MECHANICS, MATERIALS AND MECHANICAL ENGINEERING, 2013, 387 : 11 - 14
  • [37] THE EFFICIENCY OF CHELATING RESINS FOR THE PRE-CONCENTRATION OF LEAD FROM TAP WATER
    DEMORA, SJ
    HARRISON, RM
    ANALYTICA CHIMICA ACTA, 1983, 153 (OCT) : 307 - 311
  • [38] Simultaneous extraction and determination of lead, cadmium and copper in rice samples by a new pre-concentration technique: Hollow fiber solid phase microextraction combined with differential pulse anodic stripping voltammetry
    Es'haghi, Zarrin
    Khalili, Maryam
    Khazaeifar, All
    Rounaghi, Gholam Hossein
    ELECTROCHIMICA ACTA, 2011, 56 (09) : 3139 - 3146
  • [39] Separation, pre-concentration and determination of trace amounts of lead(II) ions in environmental samples using two functionalised nanoporous silica gels containing a dipyridyl sub-unit
    Javanbakht, Mehran
    Rudbaraki, Hasan
    Sohrabi, Mahmoud Reza
    Attaran, Abdol Mohammad
    Badiei, Alireza
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2010, 90 (13) : 1014 - 1024
  • [40] Application of microemulsions for the extraction, pre-concentration of PAHs as a tool for fast screening of perspective oil chemical markers
    Levkina, Valentina V.
    Pirogov, Andrey V.
    Petruk, Ekaterina S.
    Jang, Mongjoo
    Bolotnik, Timofey A.
    Mylenkova, Alexandra Y.
    Popik, Michail V.
    Buszewski, Boguslaw
    Shpigun, Oleg A.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2018, 41 (17-18) : 1004 - 1012