Application of a new nanoporous sorbent for extraction and pre-concentration of lead and copper ions

被引:39
|
作者
Zarezade, Vahid [1 ]
Aliakbari, Azam [2 ]
Es'haghi, Moosa [3 ]
Amini, Mostafa M. [2 ]
Behbahani, Mohammad [4 ]
Omidi, Fariborz [5 ]
Hesam, Ghasem [6 ]
机构
[1] Behbahan Fac Med Sci, Behbahan, Iran
[2] Shahid Beheshti Univ, Dept Chem, Tehran, Iran
[3] Islamic Azad Univ, Tabriz Branch, Dept Chem, Tabriz, Iran
[4] Kermanshah Univ Med Sci, RCEDH, Kermanshah, Iran
[5] Univ Tehran Med Sci, Sch Publ Hlth, Dept Occupat Hlth Engn, Tehran, Iran
[6] Shahroud Univ Med Sci, Sch Publ Hlth, Dept Occupat Hlth Engn, Shahroud, Iran
关键词
Siliceous mesocellular foam; mesoporous solid-phase; dithizone; lead and copper ions; fish and water samples; SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; HEAVY-METAL IONS; ACTIVATED CARBON CLOTH; ENVIRONMENTAL-SAMPLES; TRACE DETERMINATION; WATER SAMPLES; BIOLOGICAL SAMPLES; CADMIUM IONS; SILICA FOAMS;
D O I
10.1080/03067319.2017.1315638
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors describe a method for the trace determination of copper (II) and lead (II) in water and fish samples using solid-phase extraction via siliceous mesocellular foam functionalised by dithizone. Siliceous mesocellular was functionalised with dithizone, and the resulting sorbent was characterised by scanning electron microscopy, surface area analysis, thermogravimetric/differential thermal analysis and FTIR. Following solid-phase extraction of target ions by the sorbent, copper and lead ions were quantified by flame atomic absorption spectrometry. Factors affecting the sorption and desorption of target ions by the sorbent were evaluated and optimised. The calibration plot is linear in the 1 - 500 mu g L-1 copper (II) and 3-700 mu g L-1 lead (II) concentration range. The relative recovery efficiency in real sample analysis is in the range from 96 to 102%, and precision varies between 1.7 and 2.8%. It is should be noted that the limits of detection for the copper and lead analysis were 0.8 and 1.6 mu g L-1, respectively. Also, the adsorption capacities for copper and lead ions were 120 and 160 mg g(-1), respectively. The obtained pre-concentration factor for the lead and copper ions by the proposed solid-phase extraction was 75. The method was successfully applied to the determination of low levels of copper (II) and lead (II) in tap, Caspian sea, Persian gulf and lake water and also their detection in fish samples.
引用
收藏
页码:383 / 397
页数:15
相关论文
共 50 条
  • [21] Pre-concentration by solid phase extraction: Extraction of alcohols from hexane
    Bastardo, Daniel E.
    Davies, Kellie S.
    Mailloux, Shay L.
    Nelson, Heather A.
    Powers, Dale R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 241
  • [22] Ionic imprinted polymer based solid phase extraction for cadmium and lead pre-concentration/determination in seafood
    Barciela-Alonso, M. C.
    Plata-Garcia, V.
    Rouco-Lopez, A.
    Moreda-Pineiro, A.
    Bermejo-Barrera, P.
    MICROCHEMICAL JOURNAL, 2014, 114 : 106 - 110
  • [23] PRE-CONCENTRATION OF COPPER, CADMIUM, MERCURY AND LEAD FROM SEA AND TAP WATER SAMPLES ON A DITHIOCARBAMATECELLULOSE DERIVATIVE
    MURTHY, RSS
    RYAN, DE
    ANALYTICA CHIMICA ACTA, 1982, 140 (01) : 163 - 169
  • [24] Lead pre-concentration using a novel manganese dioxide resin
    Burnett, J. L.
    Croudace, I. W.
    Warwick, P. E.
    ENVIRONMENTAL EARTH SCIENCES, 2012, 67 (03) : 637 - 640
  • [25] Lead pre-concentration using a novel manganese dioxide resin
    J. L. Burnett
    I. W. Croudace
    P. E. Warwick
    Environmental Earth Sciences, 2012, 67 : 637 - 640
  • [26] Separation and pre-concentration of cadmium, copper, lead, nickel and zinc by solid-liquid extraction of their cocrystallized naphthalene dithizone chelate in saline matrices
    Costa, ACS
    Lopes, L
    Korn, MDA
    Portela, JG
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2002, 13 (05) : 674 - 678
  • [27] Multi-element pre-concentration of heavy metal ions by solid phase extraction on Chromosorb 108
    Tuzen, M
    Soylak, M
    Elci, L
    ANALYTICA CHIMICA ACTA, 2005, 548 (1-2) : 101 - 108
  • [28] New modified carbon based solid phase extraction sorbent prepared from wild cherry stone as natural raw material for the pre-concentration and determination of trace amounts of copper in food samples
    Ebrahimi, Bahram
    Mohammadiazar, Sirwan
    Ardalan, Sana
    MICROCHEMICAL JOURNAL, 2019, 147 : 666 - 673
  • [29] Application of ion-imprinted polymer synthesized by precipitation polymerization as an efficient and selective sorbent for separation and pre-concentration of chromium ions from some real samples
    Mahmoud Roushani
    Zahra Saedi
    Fatemeh Hamdi
    Hamid Reza Rajabi
    Journal of the Iranian Chemical Society, 2018, 15 : 2241 - 2249
  • [30] Characterisation and Pre-concentration of a Pegmatite Columbite Ore for Niobium Extraction
    Adeleke, Abraham
    Adegbola, Samson
    Daniyan, Ayodele
    CHARACTERIZATION OF MINERALS, METALS, AND MATERIALS 2024, 2024, : 85 - 94