Experimental performance comparison of adiabatic and internally-cooled membrane dehumidifiers

被引:21
作者
Annadurai, Gurubalan [1 ]
Tiwari, Shaligram [1 ]
Maiya, M. P. [1 ]
机构
[1] Indian Inst Technol Madras, Dept Mech Engn, Madras 600036, Tamil Nadu, India
关键词
internally cooled membrane dehumidifier; liquid desiccant dehumidification; moisture removal rate; latent effectiveness; experimental analysis; ENERGY EXCHANGERS; MASS-TRANSFER; LIQUID; SYSTEM; DESIGN;
D O I
10.1093/ijlct/cty020
中图分类号
O414.1 [热力学];
学科分类号
摘要
Humidity control of indoor space using the conventional air conditioning system is energy intensive. The liquid desiccant dehumidifier, which operates on low grade energy sources, is one of the energy efficient alternatives for humidity control. Membrane dehumidifiers avoid the desiccant carryover and hence are preferred over the packed bed dehumidifiers. However, their performance is lower due to the additional resistance in the membrane. Internal cooling is one way to improve the performance of the membrane dehumidifier and the present study experimentally investigates such a dehumidifier. The operating parameters considered are specific humidity, mass flow rate, temperature and of inlet air. The performances of the adiabatic and internally cooled dehumidifiers are presented in terms of moisture removal rate and latent effectiveness. It is found that these are higher by 60 and 50%, respectively, for the internally cooled dehumidifier.
引用
收藏
页码:240 / 249
页数:10
相关论文
共 18 条
[1]  
Abdel-Salam MRH, 2016, ASHRAE TRAN, V122, P134
[2]   Design and testing of a novel 3-fluid liquid-to-air membrane energy exchanger (3-fluid LAMEE) [J].
Abdel-Salam, Mohamed R. H. ;
Besant, Robert W. ;
Simonson, Carey J. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 92 :312-329
[3]   State-of-the-art in liquid-to-air membrane energy exchangers (LAMEEs): A comprehensive review [J].
Abdel-Salam, Mohamed R. H. ;
Ge, Gaoming ;
Fauchoux, Melanie ;
Besant, Robert W. ;
Simonson, Carey J. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 39 :700-728
[4]  
[Anonymous], 2009, ASHRAE Handbook|Fundamentals
[5]   A review of membrane contactors applied in absorption refrigeration systems [J].
Asfand, Faisal ;
Bourouis, Mahmoud .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 45 :173-191
[6]   Properties of aqueous solutions of lithium and calcium chlorides: formulations for use in air conditioning equipment design [J].
Conde, MR .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2004, 43 (04) :367-382
[7]   The role of the thermally activated desiccant cooling technologies in the issue of energy and environment [J].
Enteria, Napoleon ;
Mizutani, Kunio .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (04) :2095-2122
[8]   Experimental study on partially internally cooled dehumidification in liquid desiccant air conditioning system [J].
Gao, W. Z. ;
Shi, Y. R. ;
Cheng, Y. P. ;
Sun, W. Z. .
ENERGY AND BUILDINGS, 2013, 61 :202-209
[9]   Performance characterization of membrane dehumidifier with desiccants in flat-plate arrangement [J].
Gurubalan, A. ;
Maiya, M. P. ;
Tiwari, Shaligram .
ENERGY AND BUILDINGS, 2017, 156 :151-162
[10]   Conjugate heat and mass transfer in an internally-cooled membrane-based liquid desiccant dehumidifier (IMLDD) [J].
Huang, Si-Min ;
Zhong, Zhanrong ;
Yang, Minlin .
JOURNAL OF MEMBRANE SCIENCE, 2016, 508 :73-83