Operation performance test and energy efficiency analysis of ground-source heat pump systems

被引:39
作者
Gao, Bo [1 ]
Zhu, Xiaoyue [2 ]
Yang, Xiaojiao [2 ]
Yuan, Yanping [1 ]
Yu, Nanyang [1 ]
Ni, Ji [2 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu 610030, Peoples R China
[2] Sichuan Inst Bldg Res, Chengdu 610030, Peoples R China
关键词
Ground source heat pump; Operation performance; Field test; Energy efficiency; GEOTHERMAL-ENERGY; OPTIMIZATION;
D O I
10.1016/j.jobe.2021.102446
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The improper operation of a ground source heat pump (GSHP) system is a significant cause of poor energy efficiency. Despite the increasing popularity of GSHP systems in China, few field test has been conducted on the operation of GSHP systems in the southwest and western regions of the country, and there is a lack of comprehensive comparative study. This study tested the operation performance of 26 GSHP systems in Sichuan, Chongqing, and Shaanxi under typical operation conditions. The performances indexes of the systems were calculated and investigated, including the coefficients of performance of the heat pump and system, water transfer factor of the water pump, and energy efficiency ratio of the system. These parameters were then compared and analyzed based on existing literature and relevant domestic standards concerning energy efficiency. Accordingly, suggestions were proposed for improving the operation performance of GSHP systems from the aspects of system design, construction, and operation. Results show that the average coefficient of performance (COP) of the tested systems was less than 3.0 under heating conditions, which did not meet the requirements for energy-saving operation stipulated by the national standard and fail to achieve the initial intention of saving energy in buildings by using GSHP systems. Based on the analysis, typical problems were diagnosed in GSHP systems. Specifically, the heat pumps usually operate in part-load conditions and at low efficiency for a long time; the transfer and distribution systems operate with small temperature differences and large flows; and the settings of room temperatures tend to be unreasonable. In view of the operation performance, ground-coupled heat pump (GCHP) systems are recommended for use in the western regions of China.
引用
收藏
页数:11
相关论文
共 24 条
[1]  
[Anonymous], 2012, Design Code for Heating, Ventilation
[2]  
[Anonymous], 2015, GB 50189
[3]  
[Anonymous], 2011, ASHRAE HDB HVAC APPL, p42.1
[4]  
[Anonymous], 2013, 50801 GBT MIN HOUS U
[5]  
[Anonymous], 2007, 17981 GBT
[6]   Ground-coupled heat pumps: Part 1-Literature review and research challenges in modeling and optimal control [J].
Atam, Ercan ;
Helsen, Lieve .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 54 :1653-1667
[7]   It Works-Long-Term Performance Measurement and Optimization of Six Ground Source Heat Pump Systems in Germany [J].
Bockelmann, Franziska ;
Fisch, M. Norbert .
ENERGIES, 2019, 12 (24)
[8]   Restoration performance of vertical ground heat exchanger with various intermittent ratios [J].
Cao Xiaoling ;
Yuan Yanping ;
Sun Liangliang ;
Lei Bo ;
Yu Nanyang ;
Yang Xiaojiao .
GEOTHERMICS, 2015, 54 :115-121
[9]   Field test on energy performance of medium-depth geothermal heat pump systems (MD-GHPs) [J].
Deng, Jiewen ;
Wei, Qingpeng ;
Liang, Mei ;
He, Shi ;
Zhang, Hui .
ENERGY AND BUILDINGS, 2019, 184 :289-299
[10]   Does heat pumps perform energy efficiently as we expected: Field tests and evaluations on various kinds of heat pump systems for space heating [J].
Deng, Jiewen ;
Wei, Qingpeng ;
Liang, Mei ;
He, Shi ;
Zhang, Hui .
ENERGY AND BUILDINGS, 2019, 182 :172-186