Comparison of septal defects in 2D and 3D echocardiography using active contour models

被引:16
作者
Lassige, TA [1 ]
Benkeser, PJ [1 ]
Fyfe, D [1 ]
Sharma, S [1 ]
机构
[1] Georgia Inst Technol, Dept Elect & Comp Engn, Atlanta, GA 30332 USA
关键词
3D ultrasound; active contours; septal defects; feature extraction; segmentation;
D O I
10.1016/S0895-6111(00)00032-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Three-dimensional ultrasound is emerging as a viable resource for the imaging of internal organs. Quantitative studies correlating ultrasonic volume measurements with MRI data continue to validate this modality as a more efficient alternative for 3D imaging studies. However, the processing required to form 3D images from a set of 2D images may result in a loss of spatial resolution and may give rise to artifacts. This paper examines a method of automatic feature extraction and data quantification in 3D data sets as compared with original 2D data. This work will implement an active contour algorithm to automatically extract the endocardial borders of septal defects in echocardiographic images, and compare the size of the defects in the original 2D images and the 3D data sets. (C) 2000 Elsevier Science Ltd. AU rights reserved.
引用
收藏
页码:377 / 388
页数:12
相关论文
共 36 条
  • [1] Edge detection in prostatic ultrasound images using integrated edge maps
    Aarnink, RG
    Dev Pathak, S
    de la Rosette, JJMCH
    Debruyne, FMJ
    Kim, YM
    Wijkstra, H
    [J]. ULTRASONICS, 1998, 36 (1-5) : 635 - 642
  • [2] 3-DIMENSIONAL ULTRASOUND IMAGING OF THE ATRIAL SEPTUM - NORMAL AND PATHOLOGICAL ANATOMY
    BELOHLAVEK, M
    FOLEY, DA
    GERBER, TC
    GREENLEAF, JF
    SEWARD, JB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (06) : 1673 - 1678
  • [3] A multiple active contour model for cardiac boundary detection on echocardiographic sequences
    Chalana, V
    Linker, DT
    Haynor, DR
    Kim, YM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) : 290 - 298
  • [4] DYNAMIC 3-DIMENSIONAL ECHOCARDIOGRAPHIC ASSESSMENT OF INTRACARDIAC BLOOD-FLOW JETS
    DELABAYS, A
    SUGENG, L
    PANDIAN, NG
    HSU, TL
    HO, SJ
    CHEN, CH
    MARX, G
    SCHWARTZ, SL
    CAO, QL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (14) : 1053 - 1058
  • [5] DELACHITRE P, 1999, ULTRASOUND MED BIOL, V4, P567
  • [6] Fetal echocardiography in three and four dimensions
    Deng, J
    Gardener, JE
    Rodeck, CH
    Lees, WR
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (08) : 979 - 986
  • [7] Morphology and dynamic change of discrete subaortic stenosis can be imaged and quantified with three-dimensional transesophageal echocardiography
    Ge, SP
    Warner, JG
    Fowle, KM
    Kon, ND
    Brooker, RF
    Nomeir, AM
    Kitzman, DW
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (07) : 713 - 716
  • [8] MODEL-BASED DYNAMIC 3D RECONSTRUCTION AND DISPLAY OF THE LEFT-VENTRICLE FROM 2D CROSS-SECTIONAL ECHOCARDIOGRAMS
    GUSTAVSSON, T
    PASCHER, R
    CAIDAHL, K
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1993, 17 (4-5) : 273 - 278
  • [9] IWASE M, 1994, CIRCULATION, V90, P337
  • [10] 3-DIMENSIONAL ECHOCARDIOGRAPHY - IN-VIVO VALIDATION FOR RIGHT-VENTRICULAR VOLUME AND FUNCTION
    JIANG, L
    SIU, SC
    HANDSCHUMACHER, MD
    GUERERRO, JL
    DEPRADA, JAV
    KING, ME
    PICARD, MH
    WEYMAN, AE
    LEVINE, RA
    [J]. CIRCULATION, 1994, 89 (05) : 2342 - 2350