Cavopulmonary assist for the univentricular Fontan circulation: von Karman viscous impeller pump

被引:93
作者
Rodefeld, Mark D. [1 ]
Coats, Brandon [2 ]
Fisher, Travis [2 ]
Giridharan, Guruprasad A. [3 ]
Chen, Jun [2 ]
Brown, John W. [1 ]
Frankel, Steven H. [2 ]
机构
[1] Indiana Univ Sch Med, Sect Cardiothorac Surg, Dept Surg, Indianapolis, IN 46202 USA
[2] Purdue Univ, Dept Mech Engn, W Lafayette, IN 47907 USA
[3] Univ Louisville, Dept Bioengn, Louisville, KY 40292 USA
关键词
COMPUTATIONAL FLUID-DYNAMICS; RIGHT VENTRICLE; IN-VITRO; CONNECTION; PREDICTION; OPERATION; OUTCOMES; SUPPORT; ATRESIA;
D O I
10.1016/j.jtcvs.2010.04.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: In a univentricular Fontan circulation, modest augmentation of existing cavopulmonary pressure head (2-5 mm Hg) would reduce systemic venous pressure, increase ventricular filling, and thus substantially improve circulatory status. An ideal means of providing mechanical cavopulmonary support does not exist. We hypothesized that a viscous impeller pump, based on the von Karman viscous pump principle, is optimal for this role. Methods: A 3-dimensional computational model of the total cavopulmonary connection was created. The impeller was represented as a smooth 2-sided conical actuator disk with rotation in the vena caval axis. Flow was modeled under 3 conditions: (1) passive flow with no disc; (2) passive flow with a nonrotating disk, and (3) induced flow with disc rotation (0-5K rpm). Flow patterns and hydraulic performance were examined for each case. Hydraulic performance for a vaned impeller was assessed by measuring pressure increase and induced flow over 0 to 7K rpm in a laboratory mock loop. Results: A nonrotating actuator disc stabilized cavopulmonary flow, reducing power loss by 88%. Disk rotation (from baseline dynamic flow of 4.4 L/min) resulted in a pressure increase of 0.03 mm Hg. A further increase in pressure of 5 to 20 mm Hg and 0 to 5 L/min flow was obtained with a vaned impeller at 0 to 7K rpm in a laboratory mock loop. Conclusions: A single viscous impeller pump stabilizes and augments cavopulmonary flow in 4 directions, in the desired pressure range, without venous pathway obstruction. A viscous impeller pump applies to the existing staged protocol as a temporary bridge-to-recovery or -transplant in established univentricular Fontan circulations and may enable compressed palliation of single ventricle without the need for intermediary surgical staging or use of a systemic-to-pulmonary arterial shunt. (J Thorac Cardiovasc Surg 2010; 140: 529-36)
引用
收藏
页码:529 / 536
页数:8
相关论文
共 25 条
[1]   Contemporary outcomes after the Fontan procedure - A pediatric heart network multicenter study [J].
Anderson, Page A. W. ;
Sleeper, Lynn A. ;
Mahony, Lynn ;
Colan, Steven D. ;
Atz, Andrew M. ;
Breitbart, Roger E. ;
Gersony, Welton M. ;
Gallagher, Dianne ;
Geva, Tal ;
Margossian, Renee ;
McCrindle, Brian W. ;
Paridon, Stephen ;
Schwartz, Marcy ;
Stylianou, Mario ;
Williams, Richard V. ;
Clark, Bernard J., III .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (02) :85-98
[2]   Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics [J].
Apel, J ;
Paul, R ;
Klaus, S ;
Siess, T ;
Reul, H .
ARTIFICIAL ORGANS, 2001, 25 (05) :341-347
[3]   Outcomes after the Norwood operation in neonates with critical aortic stenosis or aortic valve atresia [J].
Ashburn, DA ;
McCrindle, BW ;
Tchervenkov, CI ;
Jacobs, ML ;
Lofland, GK ;
Bove, EL ;
Spray, TL ;
Williams, WG ;
Blackstone, EH .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (05) :1070-1082
[4]   The Fontan procedure - Our Odyssey continues [J].
Backer, Carl Lewis .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (02) :114-116
[5]   3-DIMENSIONAL NUMERICAL PREDICTION OF STRESS LOADING OF BLOOD PARTICLES IN A CENTRIFUGAL PUMP [J].
BLUDSZUWEIT, C .
ARTIFICIAL ORGANS, 1995, 19 (07) :590-596
[6]   MODEL FOR A GENERAL MECHANICAL BLOOD DAMAGE PREDICTION [J].
BLUDSZUWEIT, C .
ARTIFICIAL ORGANS, 1995, 19 (07) :583-589
[7]   The Fontan circulation: What have we learned? What to expect? [J].
de Leval, MR .
PEDIATRIC CARDIOLOGY, 1998, 19 (04) :316-320
[8]   Characteristics of Doppler myocardial echocardiography in patients with tricuspid atresia after total cavopulmonary connection with preserved systolic ventricular function [J].
Eicken, Andreas ;
Petzuch, Kurt ;
Marek, Jan ;
Vogel, Michael ;
Hager, Alfred ;
Vogt, Manfred ;
Skovranek, Jan ;
Busch, Raymonde ;
Schreiberd, Christian ;
Hess, John .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 116 (02) :212-218
[9]  
FOGEL M, 2004, CIRCULATION S, V2, P147
[10]   THE ESSENTIAL FUNCTION OF THE RIGHT VENTRICLE [J].
FUREY, SA ;
ZIESKE, HA ;
LEVY, MN .
AMERICAN HEART JOURNAL, 1984, 107 (02) :404-410