Effects of human limb gestures on galvanic coupling intra-body communication for advanced healthcare system

被引:8
|
作者
Chen, Xi Mei [1 ,2 ]
Pun, Sio Hang [1 ]
Zhao, Jian Feng [3 ]
Mak, Peng Un [2 ]
Liang, Bo Dong [3 ]
Vai, Mang I. [1 ,2 ]
机构
[1] Univ Macau, State Key Lab Analog & Mixed Signal VLSI, Ave Univ, Taipa, Macau, Peoples R China
[2] Univ Macau, Elect & Comp Engn, Ave Univ, Taipa, Macau, Peoples R China
[3] Shenzhen Polytech, West Shahe St Xili Lake, Shenzhen 518000, Guangdong, Peoples R China
来源
BIOMEDICAL ENGINEERING ONLINE | 2016年 / 15卷
关键词
Human limb gestures; Joint angle; Muscle fatigue; Bit error rate; Galvanic coupling intra-body communication; SPECTRUM; CHANNEL;
D O I
10.1186/s12938-016-0192-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Intra-Body Communication (IBC), which utilizes the human body as the transmission medium to transmit signal, is a potential communication technique for the physiological data transfer among the sensors of remote healthcare monitoring system, in which the doctors are permitted to remotely access the healthcare data without interrupt to the patients' daily activities. Methods: This work investigates the effects of human limb gestures including various joint angles, hand gripping force and loading on galvanic coupling IBC channel. The experiment results show that channel gain is significantly influenced by the joint angle (i.e. gain variation 1.09-11.70 dB, p < 0.014). The extension, as well as the appearance of joint in IBC channel increases the channel attenuation. While the other gestures and muscle fatigue have negligible effect (gain variation < 0.77 dB, p > 0.793) on IBC channel. Moreover, the change of joint angle on human limb IBC channel causes significant variation in bit error rate (BER) performance. Conclusions: The results reveal the dynamic behavior of galvanic coupling IBC channel, and provide suggestions for practical IBC system design.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Galvanic Coupling Intra-Body Communication Link for Real-Time Channel Assessment
    Tomlinson, William J., Jr.
    Chowdhury, Kaushik R.
    Yu, Christopher
    2016 IEEE CONFERENCE ON COMPUTER COMMUNICATIONS WORKSHOPS (INFOCOM WKSHPS), 2016,
  • [22] An Empirical Comparison of Limb Joint Effects on Capacitive and Galvanic Coupled Intra-Body Communications
    Seyedi, MirHojjat
    Kibret, Behailu
    Lai, Daniel T. H.
    Faulkner, Michael
    2013 IEEE EIGHTH INTERNATIONAL CONFERENCE ON INTELLIGENT SENSORS, SENSOR NETWORKS AND INFORMATION PROCESSING, 2013, : 213 - 218
  • [23] Topology Optimization for Galvanic Coupled Wireless Intra-body Communication
    Swaminathan, Meenupriya
    Muncuk, Ufuk
    Chowdhury, Kaushik R.
    IEEE INFOCOM 2016 - THE 35TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATIONS, 2016,
  • [24] Analysis and fitting of a thorax path loss based on implantable galvanic coupling intra-body communication
    Zhang S.
    Li Y.
    Yu Y.
    Kuang J.-M.
    Yang J.
    Wang J.
    Liu Y.
    Recent Advances in Computer Science and Communications, 2021, 14 (03) : 969 - 974
  • [25] Investigation of Power Consumption with Different MAC Layer Protocols for Galvanic Coupling Intra-body Communication
    Gao, Yueming
    Wu, Zhu Mei
    Wang, Zetian
    Vasic, Zeljka Lucev
    Cifrek, Mario
    6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 45 : 744 - 748
  • [26] Performance Evaluation and Improvement of PER and Throughput in Galvanic-Coupling Intra-Body Communication Systems
    Ito, Kenichi
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3742 - 3745
  • [27] Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
    Ibrahim, I. W.
    Razak, A. H. A.
    Ahmad, A.
    Salleh, M. K. M.
    4TH INTERNATIONAL CONFERENCE ON ELECTRONIC DEVICES, SYSTEMS AND APPLICATIONS 2015 (ICEDSA), 2015, 99
  • [28] Quasi-Static Field Modeling of Human Limb for Intra-Body Communication
    Pun, S. H.
    Gao, Y. M.
    Mak, P. U.
    Du, M.
    Vai, M. I.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 5, 2009, 25 : 122 - +
  • [29] Investigation and Comparison of Two Models in Galvanic Coupling Intra-body Communications
    Pun Siohang
    Gao Yueming
    Wong Kuokkit
    Mak Pengun
    Vai Mangi
    Du Min
    CHINA COMMUNICATIONS, 2010, 7 (04) : 35 - 40
  • [30] MAGIC: Magnetic Resonant Coupling for Intra-body Communication
    Banou, Stella
    Li, Kai
    Chowdhury, Kaushik
    IEEE INFOCOM 2020 - IEEE CONFERENCE ON COMPUTER COMMUNICATIONS, 2020, : 1549 - 1558